Registration of three-dimensional cardiac catheter models to single-plane fluoroscopic images

被引:12
|
作者
Meyer, SA [1 ]
Wolf, PD [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
基金
美国国家科学基金会;
关键词
catheter localization; image registration; projection-procrustes;
D O I
10.1109/10.804575
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transvenous cardiac procedures require accurate positioning of catheters within the geometrically complex cavities of the heart. Recently,nonfluoroscopic catheter tracking technologies have been developed to quantitate the(degrees-of-freedom) three-dimensional positions of intracardiac catheters. This paper presents a projection-Procrustes method to register an animated three-dimensional (3-D) model of multiple intracardiac catheters with a single-plane fluoroscopic image. Applying the computed transformation to the catheter coordinates enables the animated 3-D model of the catheters to be viewed from the same perspective as the fluoroscopic image. Mathematical simulations show that the computed transformation parameters are sensitive to both the position errors in the 3-D catheter coordinates and to the spatial distribution of the catheter-mounted transducers. Simulations with a realistic geometric model of three catheters with four transducers per catheter showed an angular error of 1.91 degrees +/- 0.27 degrees for 3-D catheter position errors of 2.0 mm, An in vitro experiment demonstrated the feasibility of the method using a water tank phantom of three catheters and fluoroscopic images taken over an 80 degrees range. The mean angular error was 0.61 degrees +/- 0.48 degrees. The results of this study indicate that the projection-Procrustes method is a useful toot for registering 3-D catheter tracking models to single-plane fluoroscopic images.
引用
收藏
页码:1471 / 1479
页数:9
相关论文
共 50 条
  • [1] Determining Three-Dimensional Catheter Location Using Single-Plane Fluoroscopy Only
    Sra, Jasbir
    Belanger, Barry
    Palma, Mark
    Krum, David
    CIRCULATION, 2013, 128 (22)
  • [2] Can magnetic resonance imaging-derived bone models be used for accurate motion measurement with single-plane three-dimensional shape registration?
    Moro-oka, Taka-aki
    Hamai, Satoshi
    Miura, Hiromasa
    Shimoto, Takeshi
    Higaki, Hidehiko
    Fregly, Benjamin J.
    Iwamoto, Yukihide
    Banks, Scott A.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2007, 25 (07) : 867 - 872
  • [3] Three-dimensional in vivo motion analysis of normal knees using single-plane fluoroscopy
    Tanifuji, Osamu
    Sato, Takashi
    Kobayashi, Koichi
    Mochizuki, Tomoharu
    Koga, Yoshio
    Yamagiwa, Hiroshi
    Omori, Go
    Endo, Naoto
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2011, 16 (06) : 710 - 718
  • [4] A method for measuring three-dimensional mandibular kinematics in vivo using single-plane fluoroscopy
    Chen, C-C
    Lin, C-C
    Chen, Y-J
    Hong, S-W
    Lu, T-W
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (01)
  • [5] Registration of two-dimensional cardiac images to preprocedural three-dimensional images for interventional applications
    Smolíková-Wachowiak, R
    Wachowiak, MP
    Fenster, A
    Drangova, M
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (02) : 219 - 228
  • [6] Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    Banks, SA
    Hodge, WA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) : 638 - 649
  • [7] Registration of cardiac magnetic resonance images with three-dimensional electroanatomical mapping to guide catheter ablation in the left ventricle
    Reddy, VY
    Malchano, ZJ
    Holmvang, G
    Schmidt, EJ
    Houghtaling, C
    Chan, RC
    Ruskin, JN
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 130A - 130A
  • [8] Accuracy of noninvasive, single-plane fluoroscopic analysis for measurement of three-dimensional femorotibial joint poses in dogs treated by tibial plateau leveling osteotomy
    Jones, Stephen C.
    Kim, Stanley E.
    Banks, Scott A.
    Conrad, Bryan P.
    Abbasi, Abdullah Z.
    Tremolada, Giovanni
    Lewis, Daniel D.
    Pozzi, Antonio
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2014, 75 (05) : 486 - 493
  • [9] Effects of uncertainty in camera geometry on three-dimensional catheter reconstruction from biplane fluoroscopic images
    Dietz, AJ
    Kynor, DB
    Friets, EM
    Triedman, JK
    Hammer, PE
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 237 - 248
  • [10] Estimation of catheter orientations from single-plane x-ray images
    Esthappan, J
    Hoffmann, KR
    MEDICAL IMAGING 2000: IMAGE DISPLAY AND VISUALIZATION, 2000, 3976 : 28 - 36