New digital reference current generation for shunt active power filter under distorted voltage conditions

被引:92
作者
Abdusalam, Mohamed [2 ]
Poure, Philippe [1 ]
Karimi, Shahram [2 ]
Saadate, Shahrokh [2 ]
机构
[1] Nancy Univ, Univ Henri Poincare, LIEN, F-54506 Vandoeuvre Les Nancy, France
[2] CNRS, UMR 7037, GREEN, F-75700 Paris, France
关键词
Active filter; Harmonics isolator; Distorted voltage conditions; Self-tuning filter; Modulated hysteresis current control;
D O I
10.1016/j.epsr.2008.10.009
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a new reference current computation method suitable for Shunt active power filter control under distorted voltage conditions is proposed. The active power filter control is based on the use of self-timing filters (STF) for the reference current generation and on a modulated hysteresis current controller. This active filter is intended for harmonic compensation of a diode rectifier feeding a IRL load under distorted voltage conditions. The Study of the active filter control is divided in two parts. The first one deals with the harmonic isolator which generates the harmonic reference Currents and is experimentally implemented in a DS1104 card of a DSPACE prototyping system. The second part focuses on the generation of the switching pattern of the inverter by using a modulated hysteresis Current controller, implemented in an analogue card. The use of STF instead of classical extraction filters allows extracting directly the voltage and current fundamental components in the alpha-beta axis without phase locked loop (PILL). The performances are good even under distorted voltage conditions. First, the effectiveness of the new proposed method is mathematically Studied and verified by computer simulation. Then, experimental results are presented using a DSPACE system associated with the analogue current controller for a real shunt active power filter. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:759 / 765
页数:7
相关论文
共 10 条
  • [1] Harmonic computation technique suitable for active power filters
    Alejandro Gonzalez, Sergio
    Garcia-Retegui, Rogelio
    Benedetti, Mario
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (05) : 2791 - 2796
  • [2] [Anonymous], P POW CONV C TOK JAP
  • [3] Optimisation-based strategy for shunt active power filter control under non-ideal supply voltages
    Chang, GW
    Yeh, CM
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2005, 152 (02): : 182 - 190
  • [4] A DSP based optimal algorithm for shunt active filter under nonsinusoidal supply and unbalanced load conditions
    George, Sincy
    Agarwal, Vivek
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (02) : 593 - 601
  • [5] Control techniques for active power filters
    Green, TC
    Marks, JH
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2005, 152 (02): : 369 - 381
  • [6] HONGSEOK S, 1999, IEEE 30 ANN POW EL S, V1, P533
  • [7] Current control techniques for three-phase voltage-source PWM converters: A survey
    Kazmierkowski, MP
    Malesani, L
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1998, 45 (05) : 691 - 703
  • [8] Comparison of control strategies for shunt active power filters in three-phase four-wire systems
    Milanes Montero, Maria Isabel
    Romero Cadaval, Enrique
    Barrero Gonzalez, Fermin
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (01) : 229 - 236
  • [9] Study of an hybrid current controller suitable for DC-DC or DC-AC applications
    Nejad, Mohammad Ali-Shamsi
    Pierfederici, Serge
    Martin, Jean-Philippe
    Meibody-Tabar, Farid
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (06) : 2176 - 2186
  • [10] A review of active filters for power quality improvement
    Singh, B
    Al-Haddad, K
    Chandra, A
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1999, 46 (05) : 960 - 971