Fixation of Extra-Articular Distal Humerus Fractures Using One Locking Plate Versus Two Reconstruction Plates: A Laboratory Study

被引:35
作者
Tejwani, Nirmal C. [1 ]
Murthy, Anjali [1 ]
Park, Jason [1 ]
McLaurin, Toni M. [1 ]
Egol, Kenneth A. [1 ]
Kummer, Fred J. [1 ]
机构
[1] NYU, Hosp Joint Dis, Dept Orthopaed, New York, NY 10016 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2009年 / 66卷 / 03期
关键词
Distal humerus fracture; Osteosynthesis; Locking plate; Plating; INVASIVE STABILIZATION SYSTEM; BIOMECHANICAL EVALUATION; INTERNAL-FIXATION; SHAFT FRACTURES; DIAPHYSEAL FRACTURES; SURGICAL EXPERIENCE; FEMUR FRACTURES; TIBIA FRACTURES;
D O I
10.1097/TA.0b013e318181e53c
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare the strength and stiffness of standard double-plate fixation with that of a single-locking plate for comminuted extra-articular distal humeral fractures. Materials: Eight matched pairs of humeri were used: One of each pair was fixed with two 3.5-mm standard reconstruction plates applied dorsally; the other was fixed with one precontoured locking plate applied to the posterior aspect of the lateral column. A 1-cm gap was created to simulate a distal fracture model with 100% metaphyseal comminution with no bony apposition. Stiffness testing of these constructs was performed in axial compression, anterior, posterior and lateral bending, and torsion. They were then cyclically loaded for 40110 cycles with 60 N in posterior bending and the stiffnesses re-tested. Finally, each construct was posteriorly loaded to failure to determine its ultimate strength. Results: The double-plate construct was significantly stiffer than the one locking plate construct in anterior bending (39%; p = 0.02), posterior bending (23%; p = 0.04), and lateral bending (60%; p = 0.01). No significant stiffness differences were seen in axial compression and torsion (p = 0.64 and 0.25, respectively). After cyclic loading, all construct stiffnesses were relatively unchanged. Both construct types had similar failure strengths (p = 0.76) of approximately 400 N. Conclusions: Double-plating provides a more rigid fixation than a single-locked plate for fixation of extra-articular comminuted distal humeral fractures. This could be clinically relevant in situations with 100% comminution as seen in gun shot injuries.
引用
收藏
页码:795 / 799
页数:5
相关论文
共 50 条
  • [21] Comparison of outcomes after triceps split versus sparing surgery for extra-articular distal humerus fractures
    Illical, Emmanuel M.
    Farrell, Dana J.
    Siska, Peter A.
    Evans, Andrew R.
    Gruen, Gary S.
    Tarkin, Ivan S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (10): : 1545 - 1548
  • [22] Volar fixation for dorsally angulated extra-articular fractures of the distal radius: A biomechanical study
    Koh, Shukuki
    Morris, Randal P.
    Patterson, Rita A.
    Kearney, J. Patrick
    Buford, William L., Jr.
    Viegas, Steven F.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (05): : 771 - 779
  • [23] Surgical Treatment of Extra-Articular or Simple Intra-Articular Distal Tibial Fractures: External Fixation versus Intramedullary Nailing
    Ristiniemi, Jukka
    Luukinen, Patrik
    Ohtonen, Pasi
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (02) : 101 - 105
  • [24] Fatigue Failure in Extra-Articular Proximal Tibia Fractures: Locking Intramedullary Nail Versus Double Locking Plates-A Biomechanical Study
    Kandemir, Utku
    Herfat, Safa
    Herzog, Mary
    Viscogliosi, Paul
    Pekmezci, Murat
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (02) : E49 - E54
  • [25] Extra-Articular Distal Humerus Plate 3D Model Creation by Using the Method of Anatomical Features
    Vitkovic, Nikola
    Stojkovic, Jelena R.
    Korunovic, Nikola
    Teutan, Emil
    Plesa, Alin
    Ianosi-Andreeva-Dimitrova, Alexandru
    Gorski, Filip
    Pacurar, Razvan
    MATERIALS, 2023, 16 (15)
  • [26] Biomechanical Analysis of Volar and Dorsal Double Locking Plates for Fixation in Comminuted Extra-articular Distal Radius Fractures: A 3D Finite Element Study
    Lin, Yu-Hao
    Lin, Chun-Li
    Kuo, Hsien-Nan
    Sun, Ming-Tsung
    Chen, Alvin Chao-Yu
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2012, 32 (05) : 349 - 355
  • [27] Biomechanical evaluation of a modified proximal humeral locking plate application for distal extra-articular diaphyseal humeral fractures
    Lim, Joon-Ryul
    Yoon, Tae-Hwan
    Choi, Yun-Rak
    Lee, Hwan-Mo
    Chun, Yong-Min
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (09) : 1877 - 1883
  • [28] Arthroplasty compared to internal fixation by locking plate osteosynthesis in comminuted fractures of the distal humerus
    Ellwein, Alexander
    Lill, Helmut
    Voigt, Christine
    Wirtz, Pauline
    Jensen, Gunnar
    Katthagen, Jan Christoph
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (04) : 747 - 754
  • [29] Arthroplasty compared to internal fixation by locking plate osteosynthesis in comminuted fractures of the distal humerus
    Alexander Ellwein
    Helmut Lill
    Christine Voigt
    Pauline Wirtz
    Gunnar Jensen
    Jan Christoph Katthagen
    International Orthopaedics, 2015, 39 : 747 - 754
  • [30] Surgical Treatment of Adult Extra-Articular Distal Humeral Diaphyseal Fractures Using an Oblique Metaphyseal Locking Compression Plate via a Posterior Approach
    Yang, Qing
    Wang, Fang
    Wang, Qiugen
    Gao, Wei
    Huang, Jianhua
    Wu, Xiaofeng
    Wu, Jiaqi
    Chen, Hao
    MEDICAL PRINCIPLES AND PRACTICE, 2011, 21 (01) : 40 - 45