Fixation of Extra-Articular Distal Humerus Fractures Using One Locking Plate Versus Two Reconstruction Plates: A Laboratory Study

被引:35
|
作者
Tejwani, Nirmal C. [1 ]
Murthy, Anjali [1 ]
Park, Jason [1 ]
McLaurin, Toni M. [1 ]
Egol, Kenneth A. [1 ]
Kummer, Fred J. [1 ]
机构
[1] NYU, Hosp Joint Dis, Dept Orthopaed, New York, NY 10016 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2009年 / 66卷 / 03期
关键词
Distal humerus fracture; Osteosynthesis; Locking plate; Plating; INVASIVE STABILIZATION SYSTEM; BIOMECHANICAL EVALUATION; INTERNAL-FIXATION; SHAFT FRACTURES; DIAPHYSEAL FRACTURES; SURGICAL EXPERIENCE; FEMUR FRACTURES; TIBIA FRACTURES;
D O I
10.1097/TA.0b013e318181e53c
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare the strength and stiffness of standard double-plate fixation with that of a single-locking plate for comminuted extra-articular distal humeral fractures. Materials: Eight matched pairs of humeri were used: One of each pair was fixed with two 3.5-mm standard reconstruction plates applied dorsally; the other was fixed with one precontoured locking plate applied to the posterior aspect of the lateral column. A 1-cm gap was created to simulate a distal fracture model with 100% metaphyseal comminution with no bony apposition. Stiffness testing of these constructs was performed in axial compression, anterior, posterior and lateral bending, and torsion. They were then cyclically loaded for 40110 cycles with 60 N in posterior bending and the stiffnesses re-tested. Finally, each construct was posteriorly loaded to failure to determine its ultimate strength. Results: The double-plate construct was significantly stiffer than the one locking plate construct in anterior bending (39%; p = 0.02), posterior bending (23%; p = 0.04), and lateral bending (60%; p = 0.01). No significant stiffness differences were seen in axial compression and torsion (p = 0.64 and 0.25, respectively). After cyclic loading, all construct stiffnesses were relatively unchanged. Both construct types had similar failure strengths (p = 0.76) of approximately 400 N. Conclusions: Double-plating provides a more rigid fixation than a single-locked plate for fixation of extra-articular comminuted distal humeral fractures. This could be clinically relevant in situations with 100% comminution as seen in gun shot injuries.
引用
收藏
页码:795 / 799
页数:5
相关论文
共 50 条
  • [11] Ilizarov external fixation versus plate osteosynthesis in the management of extra-articular fractures of the distal tibia
    Fadel, Mohamed
    Ahmed, Mohamed Ali
    Al-Dars, Ahmed Mounir
    Maabed, Mustafa Ahmed
    Shawki, Hashem
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (03) : 513 - 519
  • [12] Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate
    Tarallo L.
    Mugnai R.
    Adani R.
    Catani F.
    Journal of Orthopaedics and Traumatology, 2014, 15 (4) : 285 - 290
  • [13] Risk factors for hardware-related complications after extra-articular distal humerus fracture fixation using an anatomical locking plate
    Hyoung-Seok Jung
    Yoo-Sun Won
    Yang-Seon Choi
    Jae-Sung Lee
    European Journal of Trauma and Emergency Surgery, 2023, 49 : 125 - 131
  • [14] Retrograde tibial intramedullary nail versus minimally invasive locking plate for extra-articular distal tibial fractures: a comparative and retrospective study
    Liu, Hui
    Xu, Weizhen
    Xiong, Yuanfei
    Zhang, Jinhui
    Xu, Zunying
    Wu, Jin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [15] Locking plates for fixation of extra-articular fractures of the first metacarpal base: A series of 15 cases
    Diaconu, M.
    Facca, S.
    Gouzou, S.
    Liverneaux, Ph.
    CHIRURGIE DE LA MAIN, 2011, 30 (01) : 26 - 30
  • [16] Functional and Radiological Outcome in Distal Third Humerus Fracture Treated with Extra-articular Locking Plate: A Multicentric Retrospective Study
    Gupta, Ashis Kumar
    Samal, Barada Prasanna
    Dalei, Tushar Ranjan
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (06): : S1483 - S1487
  • [17] What happens to the posterior comminution in extra-articular fractures of the distal radius treated with volar locking plates?
    Guillou, J.
    Darees, M.
    Pouges, C.
    Christiaens, N.
    Guerre, E.
    Chantelot, C.
    HAND SURGERY & REHABILITATION, 2019, 38 (02) : 91 - 96
  • [18] A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates
    Korner, J
    Diederichs, G
    Arzdorf, M
    Lill, H
    Josten, C
    Schneider, E
    Linke, B
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (05) : 286 - 293
  • [19] Intramedullary nail versus volar locking plate fixation for the treatment of extra-articular or simple intra-articular distal radius fractures: systematic review and meta-analysis
    Zhang, Bing
    Chang, Hengrui
    Yu, Kunlun
    Bai, Jiangbo
    Tian, Dehu
    Zhang, Guisheng
    Shao, Xinzhong
    Zhang, Yingze
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (10) : 2161 - 2169
  • [20] A COMPARATIVE STUDY OF INTRAMEDULLARY INTERLOCKING NAIL AND LOCKING PLATE FIXATION IN THE MANAGEMENT OF EXTRA ARTICULAR DISTAL TIBIAL FRACTURES
    Pawar, Eknath D.
    Agrawal, Saurabh R.
    Patil, Atul W.
    Choudhary, Sandeep
    Asadi, Ghaniuzzoha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (24): : 6812 - 6826