The Influence of Luting Systems on the Microtensile Bond Strength of Dentin to Indirect Resin-based Composite and Ceramic Restorations

被引:39
作者
D'Arcangelo, C. [1 ]
De Angelis, F. [1 ]
D'Amario, M. [2 ]
Zazzeroni, S. [1 ]
Ciampoli, C. [1 ]
Caputi, S. [3 ]
机构
[1] Univ G dAnnunzio, Sch Dent, Dept Operat Dent, Chieti, Italy
[2] Univ Aquila, Dent Clin, Dept Restorat Dent, I-67100 Laquila, Italy
[3] Univ G dAnnunzio, Sch Dent, Dept Oral Sci, Chieti, Italy
关键词
SELF-ETCH ADHESIVES; PERMEABLE MEMBRANES; MARGINAL ADAPTATION; SURFACE TREATMENTS; SINGLE-STEP; IN-VITRO; CEMENTS; AGENTS; POLYMERIZATION; ENAMEL;
D O I
10.2341/08-101
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Microtensile bond strength (mu TBS) evaluation and fractographic analysis were used to compare four luting systems in the cementation of resin-based composite (RBC) and ceramic disks to dentin. Forty freshly-extracted molars were transversally sectioned to expose flat, deep dentin surfaces. Forty cylindrical specimens (5-mm diameter and 10-mm height), consisting of 20 RBC disks and 20 leucite-based glass ceramic disks, were produced. The RBC disks were sandblasted with 50-mu m Al2O3. The ceramic disks were conditioned with 9.5% hydrofluoric acid gel and silane application. All the disks were then bonded to dentin surfaces according to the luting cements to be used: two etch-and-rinse luting agents (XP bond/CoreXFlow; Dentsply [XP]) (Enabond/EnaCem HF; Micerium [ENA]), a selfetch luting system (ED Primer II A+B/Panavia F2.0; Kuraray-Dental [PAN]) and a self-adhesive luting agent (RelyX Unicem; 3M ESPE [UNI]). The adhesive/luting cement systems were applied according to the manufacturers' instructions. The specimens were sectioned perpendicular to the adhesive interface to produce multiple beams, approximately 1 mm(2) in area. All the specimen preparations were performed by the same operator. The beams were tested under tension at a crosshead speed of 0.5 mm/minute until failure. The mu TBS data were analyzed by two different one-way-ANOVA and multiple comparison Tukey tests (alpha=0.05). All the fractured beams were observed using a Scanning Electron Microscope (SEM) at 200x magnification for fracture mode determination. The mean bond strength in MPa (SD) for the RBC (Co) and ceramic (Ce) groups were: XP-Co = 31.39 (13.51), ENA-Co = 30.93 (10.17), PAN-Co = 18.29 (10.02), UNI-Co = 19.33 (7.91); XP-Ce = 4.83 (1.86), ENA-Ce = 5.15 (1.66), PAN-Ce = 4.36 (1.80), UNI-Ce = 7.16 (2.52). Statistical analysis showed that the bond strengths were significantly affected by the luting agent employed for both the RBC and ceramic groups (p<0.001). In particular, the XP-Co group and the ENA-Co group did not differ from each other (p>0.05) and showed significantly higher bond strengths than the PAN-Co and UNI-Co groups (p<0.05). On the contrary, the UNI-Ce group showed the highest bond strengths compared to the other ceramic experimental groups (p<0.05). Regarding failure mode, differences were found between the RBC groups: for the etch-and-rinse luting systems (XP-Co and ENA-Co groups), most failures occurred cohesively in the luting agent, while the self-etch luting system (PAN-Co group) and self-adhesive luting system (UNI-Co group) failed predominantly adhesively at the luting agent-dentin interface. Little differences were found between the ceramic groups, where failure type was primarily adhesive between cement and ceramic.
引用
收藏
页码:328 / 336
页数:9
相关论文
共 38 条
[1]   Microtensile bond strength of a resin cement to glass infiltrated zirconia-reinforced ceramic:: The effect of surface conditioning [J].
Amaral, R ;
Özcan, M ;
Bottino, MA ;
Valandro, LF .
DENTAL MATERIALS, 2006, 22 (03) :283-290
[2]  
Blank J T, 2000, J Esthet Dent, V12, P195, DOI 10.1111/j.1708-8240.2000.tb00222.x
[3]   Microtensile bond strength of a resin cement to feldpathic ceramic after different etching and silanization regimens in dry and aged conditions [J].
Brentel, Aline Scalone ;
Ozcan, Mutlu ;
Valandro, Luiz Felipe ;
Alarca, Lilian Guimaraes ;
Amaral, Regina ;
Bottino, Marco Antonio .
DENTAL MATERIALS, 2007, 23 (11) :1323-1331
[4]   A challenge to the conventional wisdom that simultaneous etching and resin infiltration always occurs in self-etch adhesives [J].
Carvalho, RM ;
Chersoni, S ;
Frankenberger, R ;
Pashley, DH ;
Prati, C ;
Tay, FR .
BIOMATERIALS, 2005, 26 (09) :1035-1042
[5]   Adhesive permeability affects coupling of resin cements that utilise self-etching primers to dentine [J].
Carvalho, RM ;
Pegoraro, TA ;
Tay, FR ;
Pegoraro, LF ;
Silva, NRFA ;
Pashley, DH .
JOURNAL OF DENTISTRY, 2004, 32 (01) :55-65
[6]  
D'Arcangelo C, 2007, J ADHES DENT, V9, P319
[7]   Bonding of an auto-adhesive luting material to enamel and dentin [J].
De Munck, J ;
Vargas, M ;
Van Landuyt, K ;
Hikita, K ;
Lambrechts, P ;
Van Meerbeek, B .
DENTAL MATERIALS, 2004, 20 (10) :963-971
[8]  
Escribano N, 2006, J ADHES DENT, V8, P337
[9]   'No-bottle' vs 'multi-bottle' dentin adhesives - a microtensile bond strength and morphological study [J].
Frankenberger, R ;
Perdigao, J ;
Rosa, BT ;
Lopes, A .
DENTAL MATERIALS, 2001, 17 (05) :373-380
[10]  
Frankenberger R, 2000, OPER DENT, V25, P324