Bio-compatible in-tube solid-phase microextraction capillary for the direct extraction and high-performance liquid chromatographic determination of drugs in human serum

被引:95
作者
Mullett, WM
Levsen, K
Lubda, D
Pawliszyn, J
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Fraunhofer Inst Toxicol & Aerosol Res, D-30625 Hannover, Germany
[3] Merck KGAA, D-64271 Darmstadt, Germany
关键词
in-tube solid-phase microextraction; solid-phase microextraction; restricted access media; alkyl-diol silica columns; benzodiazepines;
D O I
10.1016/S0021-9673(02)00216-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A restricted access material (RAM), alkyl-diol-silica (ADS), was used to prepare a highly bio-compatible solid-phase microextraction (SPME) capillary for the automated and direct in-tube extraction of several benzodiazepines from human serum. The bifunctionality of the ADS extraction phase prevented fouling of the capillary by protein adsorption while simultaneously trapping the analytes in the hydrophobic porous interior. This the first report of a restricted access material utilized as an extraction phase for in-tube SPME. The approach simplified the required apparatus in comparison to existing RAM column switching procedures, and more importantly eliminated the excessive use of extraction solvents. The biocompatibility of the ADS material also overcame the existing problems with in-tube SPME that requires an ultrafiltration or other deproteinization step prior to handling biological samples, therefore further minimizing the sample preparation requirements. The calculated oxazepam, temazepam, nordazepam and diazepam detection limits were 26, 29, 22 and 24 ng/ml in serum, respectively. The method was linear over the range of 50-50 000 ng/ml with an average linear coefficient (R-2) value of 0.9998. The injection repeatability and intra-assay precision of the method were evaluated with five injections of a 10-mug/ml serum sample (spiked with all compounds), resulting in an average RSD<7%. The ADS extraction column was robust, providing many direct injections of biological fluids for the extraction and subsequent determination of benzodiazepines. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:325 / 334
页数:10
相关论文
共 36 条
[1]   High-performance liquid chromatographic determination of drugs and metabolites in human serum and urine using direct injection and a unique molecular sieve [J].
Ambrose, DL ;
Fritz, JS .
JOURNAL OF CHROMATOGRAPHY B, 1998, 709 (01) :89-96
[2]  
BASELT RC, 1990, DEPOSITION TOXIC DRU, P249
[3]   High-performance liquid chromatography integrated solid-phase extraction in bioanalysis using restricted access precolumn packings [J].
Boos, KS ;
Grimm, CH .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (03) :175-180
[4]   ALKYL-DIOL SILICA (ADS) - RESTRICTED ACCESS PRECOLUMN PACKINGS FOR DIRECT-INJECTION AND COUPLED-COLUMN CHROMATOGRAPHY OF BIOFLUIDS [J].
BOOS, KS ;
RUDOLPHI, A ;
VIELHAUER, S ;
WALFORT, A ;
LUBDA, D ;
EISENBEISS, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8) :684-690
[5]   Development of an HPLC method for the toxicological screening of central nervous system drugs [J].
Casamenti, G ;
Mandrioli, R ;
Sabbioni, C ;
Bugamelli, F ;
Volterra, V ;
Raggi, MA .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (07) :1039-1059
[6]   Validated method for the therapeutic drug monitoring of flunitrazepam in human serum using liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry with an ion trap detector [J].
Darius, J ;
Banditt, P .
JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (02) :437-441
[7]   Methods for the measurement of benzodiazepines in biological samples [J].
Drummer, OH .
JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (01) :201-225
[8]   Automated in-tube solid-phase microextraction coupled to high-performance liquid chromatography [J].
Eisert, R ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3140-3147
[9]   High-performance liquid chromatographic method for the determination of benzodiazepines in plasma or serum using the column-switching technique [J].
El Mahjoub, A ;
Staub, C .
JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (02) :381-390
[10]   Uniform-sized molecularly imprinted polymers for 2-arylpropionic acid derivatives selectively modified with hydrophilic external layer and their applications to direct serum injection analysis [J].
Haginaka, J ;
Sanbe, H .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5206-5210