Implantation of the Subcutaneous Implantable Cardioverter-Defibrillator An Evaluation of 4 Implantation Techniques

被引:52
作者
Brouwer, Tom F. [1 ]
Miller, Marc A. [2 ]
Quast, Anne-Floor B. E. [1 ]
Palaniswamy, Chandrasekar [2 ]
Dukkipati, Srinivas R. [2 ]
Reddy, Vivek [2 ]
Wilde, Arthur A. [1 ]
Willner, Jonathan M. [2 ]
Knops, Reinoud E. [1 ]
机构
[1] Univ Amsterdam, Amsterdam Med Ctr, Ctr Heart, Dept Clin & Expt Cardiol, Noord Holland, Netherlands
[2] Icahn Sch Med Mt Sinai, Helmsley Cardiac Arrhythmia Serv, New York, NY 10029 USA
关键词
implantable cardioverter-defibrillator; implantation; implantation technique; subcutaneous implantable cardioverter-defibrillator; ventricular arrhythmia;
D O I
10.1161/CIRCEP.116.004663
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Alternative techniques to the traditional 3-incision subcutaneous implantation of the subcutaneous implantable cardioverter-defibrillator may offer procedural and cosmetic advantages. We evaluate 4 different implant techniques of the subcutaneous implantable cardioverter-defibrillator. Methods and Results-Patients implanted with subcutaneous implantable cardioverter-defibrillators from 2 hospitals between 2009 and 2016 were included. Four implantation techniques were used depending on physician preference and patient characteristics. The 2- and 3-incision techniques both place the pulse generator subcutaneously, but the 2-incision technique omits the superior parasternal incision for lead positioning. Submuscular implantation places the pulse generator underneath the serratus anterior muscle and subfascial implantation underneath the fascial layer on the anterior side of the serratus anterior muscle. Reported outcomes include perioperative parameters, defibrillation testing, and clinical follow-up. A total of 246 patients were included with a median age of 47 years and 37% female. Fifty-four patients were implanted with the 3-incision technique, 118 with the 2-incision technique, 38 with submuscular, and 37 with subfascial. Defibrillation test efficacy and shock lead impedance during testing did not differ among the groups; respectively, P=0.46 and P=0.18. The 2-incision technique resulted in the shortest procedure duration and time-to-hospital discharge compared with the other techniques (P<0.001). A total of 18 complications occurred, but there were no significant differences between the groups (P=0.21). All infections occurred in subcutaneous implants (3-incision, n=3; 2-incision, n=4). In the 2-incision group, there were no lead displacements. Conclusions-The presented implantation techniques are feasible alternatives to the standard 3-incision subcutaneous implantation, and the 2-incision technique resulted in shortest procedure duration.
引用
收藏
页数:7
相关论文
共 9 条
[1]   An Entirely Subcutaneous Implantable Cardioverter-Defibrillator [J].
Bardy, Gust H. ;
Smith, Warren M. ;
Hood, Margaret A. ;
Crozier, Ian G. ;
Melton, Iain C. ;
Jordaens, Luc ;
Theuns, Dominic ;
Park, Robert E. ;
Wright, David J. ;
Connelly, Derek T. ;
Fynn, Simon P. ;
Murgatroyd, Francis D. ;
Sperzel, Johannes ;
Neuzner, Joerg ;
Spitzer, Stefan G. ;
Ardashev, Andrey V. ;
Oduro, Amo ;
Boersma, Lucas ;
Maass, Alexander H. ;
Van Gelder, Isabelle C. ;
Wilde, Arthur A. ;
van Dessel, Pascal F. ;
Knops, Reinoud E. ;
Barr, Craig S. ;
Lupo, Pierpaolo ;
Cappato, Riccardo ;
Grace, Andrew A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (01) :36-44
[2]  
Brouwer Tom F, 2016, JACC Clin Electrophysiol, V2, P89, DOI 10.1016/j.jacep.2015.09.011
[3]   Safety and Efficacy of the Totally Subcutaneous Implantable Defibrillator 2-Year Results From a Pooled Analysis of the IDE Study and EFFORTLESS Registry [J].
Burke, Martin C. ;
Gold, Michael R. ;
Knight, Bradley P. ;
Barr, Craig S. ;
Theuns, Dominic A. M. J. ;
Boersma, Lucas V. A. ;
Knops, Reinoud E. ;
Weiss, Raul ;
Leon, Angel R. ;
Herre, John M. ;
Husby, Michael ;
Stein, Kenneth M. ;
Lambiase, Pier D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (16) :1605-1615
[4]   Long-Term Outcomes after Pocket or Scar Revision and Reimplantation of Pacemakers with Preerosion [J].
Cassagneau, Romain ;
Ploux, Sylvain ;
Ritter, Philippe ;
Jan, Emilie ;
Barandon, Laurent ;
Deplagne, Antoine ;
Clementy, Jacques ;
Haiessaguerre, Michel ;
Bordachar, Pierre .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (02) :150-154
[5]   The learning curve associated with the introduction of the subcutaneous implantable defibrillator [J].
Knops, Reinoud E. ;
Brouwer, Tom F. ;
Barr, Craig S. ;
Theuns, Dominic A. ;
Boersma, Lucas ;
Weiss, Raul ;
Neuzil, Petr ;
Scholten, Marcoen ;
Lambiase, Pier D. ;
Leon, Angel R. ;
Hood, Margaret ;
Jones, Paul W. ;
Wold, Nicholas ;
Grace, Andrew A. ;
Nordkamp, Louise R. A. Olde ;
Burke, Martin C. .
EUROPACE, 2016, 18 (07) :1010-1015
[6]   Two-incision technique for implantation of the subcutaneous implantable cardioverter-defibrillator [J].
Knops, Reinoud E. ;
Nordkamp, Louise R. A. Olde ;
de Groot, Joris R. ;
Wilde, Arthur A. M. .
HEART RHYTHM, 2013, 10 (08) :1240-1243
[7]   Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry [J].
Lambiase, Pier D. ;
Barr, Craig ;
Theuns, Dominic A. M. J. ;
Knops, Reinoud ;
Neuzil, Petr ;
Johansen, Jens Brock ;
Hood, Margaret ;
Pedersen, Susanne ;
Kaeaeb, Stefan ;
Murgatroyd, Francis ;
Reeve, Helen L. ;
Carter, Nathan ;
Boersma, Lucas .
EUROPEAN HEART JOURNAL, 2014, 35 (25) :1657-+
[8]   Rationale and design of the PRAETORIAN trial: A Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter-defibrillator therapy [J].
Nordkamp, Louise R. A. Olde ;
Knops, Reinoud E. ;
Bardy, Gust H. ;
Blaauw, Yuri ;
Boersma, Lucas V. A. ;
Bos, Johannes S. ;
Delnoy, Peter Paul H. M. ;
van Dessel, Pascal F. H. M. ;
Driessen, Antoine H. G. ;
de Groot, Joris R. ;
Herrman, Jean Paul R. ;
Jordaens, Luc J. L. M. ;
Kooiman, Kirsten M. ;
Maass, Alexander H. ;
Meine, Mathias ;
Mizusawa, Yuka ;
Molhoek, Sander G. ;
van Opstal, Jurjen ;
Tijssen, Jan G. P. ;
Wilde, Arthur A. M. .
AMERICAN HEART JOURNAL, 2012, 163 (05) :753-+
[9]   How to make a submuscular pocket [J].
Pena, Rafael E. ;
Shepard, Richard K. ;
Ellenbogen, Kenneth A. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (12) :1381-1383