Test-retest reliability and minimal detectable change scores of twelve functional fitness tests in adults with Down syndrome

被引:32
作者
Boer, P. H. [1 ]
Moss, S. J. [1 ]
机构
[1] North West Univ, Phys Act Sport & Recreat PhASRec Res Focus Area, Fac Hlth Sci, ZA-2520 Potchefstroom, South Africa
关键词
Down syndrome; Feasibility; Reliability; Functional fitness; Strength; Aerobic capacity; 6-MINUTE WALK TEST; RANDOMIZED CONTROLLED-TRIAL; INTELLECTUAL DISABILITY; PHYSICAL-FITNESS; MENTAL-RETARDATION; OLDER-ADULTS; MUSCLE STRENGTH; YOUNG-ADULTS; VALIDITY; INDIVIDUALS;
D O I
10.1016/j.ridd.2015.10.022
中图分类号
G76 [特殊教育];
学科分类号
040109 ;
摘要
Aim: The purpose of the study was to explore the test-retest reliability and minimal detectable change of selected functional fitness test items in adults with Down syndrome. Methods: Forty-three adults with Down syndrome (24 men and 19 women) aged 18-50 years completed a battery of tests twice in a two-week period. The battery of tests consisted of two balance items, two flexibility items, five muscular strength and endurance items, two aerobic items, and one functional task. All items were considered valid and reliable tests in a general elderly or intellectually disabled population. The test retest relative reliability for all repeated tests was assessed with intraclass correlation coefficient performing one-way analysis of variance. The test retest absolute variability was measured by using the standard error of measurement (SEM) to calculate the minimal detectable change at the 90% confidence interval (MDC90). Reliability data was visualised with a Bland-Altman plot. Results: All tests showed excellent intraclass correlation coefficients (ICC's > 0.9). All SEM values demonstrated acceptable measurement precision (SEM < SD/2). Values for MDC90 are provided for all 12 tests. The analyses indicated that there was no major systematic bias in the plots. The scatter around the Bland-Altman was distributed randomly. Conclusion: All twelve functional fitness tests demonstrated adequate feasibility and relative and absolute test retest reliability in adults with Down syndrome in South Africa. Information of this nature will help to monitor performance alterations over time and success of training interventions. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:176 / 185
页数:10
相关论文
共 52 条
  • [1] Abbag FI, 2006, SAUDI MED J, V27, P219
  • [2] Validity and usefulness of hand-held dynamometry for measuring muscle strength in community-dwelling older persons
    Abizanda, Pedro
    Luis Navarro, Jose
    Isabel Garcia-Tomas, Maria
    Lopez-Jimenez, Esther
    Martinez-Sanchez, Esther
    Paterna, Gema
    [J]. ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2012, 54 (01) : 21 - 27
  • [3] American College of Sports Medicine, 2005, ACSMS HLTH RELATED P
  • [4] Aging and down syndrome: implications for physical therapy
    Barnhart, Robert C.
    Connolly, Barbara
    [J]. PHYSICAL THERAPY, 2007, 87 (10): : 1399 - 1406
  • [5] Heart rate variability at rest and during exercise in persons with Down syndrome
    Baynard, T
    Pitetti, KH
    Guerra, M
    Fernhall, B
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (08): : 1285 - 1290
  • [6] Age-Related Changes in Aerobic Capacity in Individuals with Mental Retardation: A 20-yr Review
    Baynard, Tracy
    Pitetti, Kenneth H.
    Guerra, Myriam
    Unnithan, Vish B.
    Fernhall, Bo
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (11) : 1984 - 1989
  • [7] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [8] Carmeli E., 2002, Journal of Musculoskeletal & Neuronal Interactions, V2, P457
  • [9] Carmeli Eli, 2004, Downs Syndr Res Pract, V9, P17
  • [10] Test-Retest Reliability of the 6-Minute Walk Test in Individuals With Down Syndrome
    Casey, Amanda F.
    Wang, Xu
    Osterling, Kristin
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (11): : 2068 - 2074