Incomplete Stent Apposition Causes High Shear Flow Disturbances and Delay in Neointimal Coverage as a Function of Strut to Wall Detachment Distance Implications for the Management of Incomplete Stent Apposition

被引:165
|
作者
Foin, Nicolas [1 ,2 ]
Gutierrez-Chico, Juan Luis [3 ,4 ]
Nakatani, Shimpei [3 ]
Torii, Ryo [5 ]
Bourantas, Christos V. [3 ]
Sen, Sayan [1 ]
Nijjer, Sukhjinder [1 ]
Petraco, Ricardo [1 ]
Kousera, Chrysa [1 ]
Ghione, Matteo [6 ]
Onuma, Yoshinobu [3 ]
Garcia-Garcia, Hector M. [3 ,7 ]
Francis, Darrel P. [1 ]
Wong, Philip [2 ]
Di Mario, Carlo [6 ]
Davies, Justin E. [1 ]
Serruys, Patrick W. [1 ,3 ,7 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Int Ctr Circulatory Hlth, NHLI, London, England
[2] Natl Heart Ctr Singapore, Singapore, Singapore
[3] Erasmus MC, Thoraxctr, Rotterdam, Netherlands
[4] Univ Munich, Munich, Germany
[5] UCL, Dept Mech Engn, London, England
[6] Royal Brompton & Harefield NHS Trust, NIHR, BRU, London, England
[7] Cardialysis, Rotterdam, Netherlands
关键词
angioplasty; blood flow velocity; stents; thrombosis; OPTICAL COHERENCE TOMOGRAPHY; DRUG-ELUTING STENTS; HUMAN CORONARY-ARTERIES; SIDE-BRANCH STRUTS; BARE-METAL STENT; IN-VIVO; INTRAVASCULAR ULTRASOUND; BLOOD-FLOW; IMPLANTATION; THROMBOSIS;
D O I
10.1161/CIRCINTERVENTIONS.113.000931
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Lack of re-endothelialization and neointimal coverage on stent struts has been put forward as the main underlying mechanism leading to late stent thrombosis. Incomplete stent apposition (ISA) has been observed frequently in patients with very late stent thrombosis after drug eluting stent implantation, suggesting a role of ISA in the pathogenesis of this adverse event. The aim of this study was to evaluate the impact of different degrees of ISA severity on abnormal shear rate and healing response with coverage, because of its potential implications for stent optimization in clinical practice. Methods and Results-We characterized flow profile and shear distribution in different cases of ISA with increasing strut-wall detachment distance (ranging from 100 to 500 mu m). Protruding strut and strut malapposed with moderate detachment (ISA detachment distance <100 mu m) have minimal disturbance to blood flow as compared with floating strut that has more significant ISA distance. In vivo impact on strut coverage was assessed retrospectively using optical coherence tomography evaluation on 72 stents (48 patients) sequentially at baseline and after 6-month follow-up. Analysis of coverage revealed an important impact of baseline strut-wall ISA distance on the risk of incomplete strut coverage at follow-up. Malapposed segments with an ISA detachment <100 mu m at baseline showed complete strut coverage at follow-up, whereas segments with a maximal ISA detachment distance of 100 to 300 mu m and >300 m had 6.1% and 15.7% of their struts still uncovered at follow-up, respectively (P<0.001). Conclusions-Flow disturbances and risk of delayed strut coverage both increase with ISA detachment distance. Insights from this study are important for understanding malapposition as a quantitative, rather than binary phenomenon (present or absent) and to define the threshold of ISA detachment that might benefit from optimization during stent implantation.
引用
收藏
页码:180 / 189
页数:10
相关论文
共 2 条
  • [1] Cut-off value of strut-vessel distance for the resolution of acute incomplete stent apposition in the early phase using serial optical coherence tomography after cobalt-chromium everolimus-eluting stent implantation
    Oda, Hideto
    Itoh, Tomonori
    Sasaki, Wataru
    Uchimura, Yohei
    Taguchi, Yuya
    Kaneko, Kyosuke
    Sakamoto, Tsubasa
    Goto, Iwao
    Sakuma, Masafumi
    Ishida, Masaru
    Kikuchi, Tatsuo
    Terashita, Daisuke
    Otake, Hiromasa
    Morino, Yoshihiro
    Shinke, Toshiro
    JOURNAL OF CARDIOLOGY, 2020, 75 (06) : 641 - 647
  • [2] Improved strut coverage and less late incomplete apposition with thin-strut TAXUS Liberte vs. TAXUS Express: the importance of stent platform design for drug-eluting stents
    Weissman, Neil J.
    Turco, Mark A.
    Ormiston, John A.
    Mann, Tift
    Cannon, Louis A.
    McGarry, Thomas F.
    Webster, Mark W. I.
    Hall, Jack J.
    Lucca, Michael J.
    Mishkel, Gregory J.
    Wu, Chiung-Jen
    Mandinov, Lazar
    Dawkins, Keith D.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2011, 12 (04) : 247 - 257