Digital CZT Detector System for High Flux Energy-Resolved X-ray Imaging

被引:0
作者
Abbene, L. [1 ]
Principato, F. [1 ]
Gerardi, G. [1 ]
Benassi, G. [3 ]
Zambelli, N. [3 ]
Zappettini, A. [2 ]
Bettelli, M. [2 ]
Seller, P. [4 ]
Veale, M. C. [4 ]
机构
[1] Univ Palermo, Dipartimcnto Fis & Chim, Viale Sci,Editicio 18, I-90128 Palermo, Italy
[2] IMEM CNR, Parco Area Sci 37-A, I-43100 Parma, Italy
[3] Due2lab Srl, Via Paolo Borsellino 2, I-42019 Reggio Emilia, Italy
[4] Rutherford Appleton Lab, Sci & Technol Facil Council, Chilton OX11 0QX, Oxfordshire, England
来源
2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD) | 2016年
关键词
SMALL PIXEL; CDTE; PERFORMANCE; RESOLUTION; PROGRESS; CT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Photon counting arrays with energy resolving capabilities are recently desired for the next-generation X-ray imaging systems. In this work, we present the performance of a 2 mm thick CZT pixel detector, with pixel pitches of 500 mu m and 250 mu m, coupled to a fast and low noise ASIC (PIXIE ASIC), characterized by only the preamplifier stage. A 16-channel digital readout electronics was used to continuously digitize and process each output channel from the PIXIE ASIC, performing multi-parameter analysis (event arrival time, pulse shape, pulse height) at low and high input counting rates (ICRs). The spectroscopic response of the system to monochromatic X-ray and gamma ray sources, at both low and high ICRs, is presented with particular attention to the mitigation of some typical spectral distortions (pile-up and charge sharing). The detector allows good energy resolution at moderate cooling (3% FWHM 59.5 keV, -1200 V, T = 5 C) by using fast shaped pulses (i.e. pulses with time widths of 300 ns). Charge sharing investigations were performed by using a fine time coincidence analysis (TCA) and a pulse shape analysis (PSA). The potentialities of the PSA for charge sharing detection even at high photon counting rates were also shown.
引用
收藏
页数:7
相关论文
共 40 条
  • [11] CdTe Linear Pixel X-Ray Detector With Enhanced Spectrometric Performance for High Flux X-Ray Imaging
    Brambilla, A.
    Ouvrier-Buffet, P.
    Rinkel, J.
    Gonon, G.
    Boudou, C.
    Verger, L.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1552 - 1558
  • [12] Fast CdTe and CdZnTe Semiconductor Detector Arrays for Spectroscopic X-Ray Imaging
    Brambilla, Andrea
    Ouvrier-Buffet, P.
    Gonon, G.
    Rinkel, J.
    Moulin, V.
    Boudou, C.
    Verger, L.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 408 - 415
  • [13] Numerical modeling of charge sharing in CdZnTe pixel detectors
    Chen, CMH
    Boggs, SE
    Bolotnikov, AE
    Cook, WR
    Harrison, FA
    Schindler, SM
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 270 - 276
  • [14] Characterization of traveling heater method (THM) grown Cd0.9Zn0.1Te crystals
    Chen, Henry
    Awadalla, Salah A.
    Mackenzie, Jason
    Redden, Robert
    Bindley, Glenn
    Bolotnikov, A. E.
    Camarda, G. S.
    Carini, G.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (04) : 811 - 816
  • [15] Del Sordo S, 2004, NUOVO CIM B, V119, P257, DOI [10.1393/ncb/i2004-10075-0, 10.1393/ncb/i2004-10075-o]
  • [16] Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications
    Del Sordo, Stefano
    Abbene, Leonardo
    Caroli, Ezio
    Mancini, Anna Maria
    Zappettini, Andrea
    Ubertini, Pietro
    [J]. SENSORS, 2009, 9 (05) : 3491 - 3526
  • [17] Energy resolution of a photon-counting silicon strip detector
    Fredenberg, Erik
    Lundqvist, Mats
    Cederstrom, Bjorn
    Aslund, Magnus
    Danielsson, Mats
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 613 (01) : 156 - 162
  • [18] A digital approach for real time high-rate high-resolution radiation measurements
    Gerardi, G.
    Abbene, L.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 768 : 46 - 54
  • [19] Development of a simplified simulation model for performance characterization of a pixellated CdZnTe multimodality imaging system
    Guerra, P.
    Santos, A.
    Darambara, D. G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (04) : 1099 - 1113
  • [20] CZT detector technology for medical imaging
    Iniewski, K.