Targeted profiling of polar intracellular metabolites using ion-pair-high performance liquid chromatography and -ultra high performance liquid chromatography coupled to tandem mass spectrometry: Applications to serum, urine and tissue extracts

被引:67
作者
Michopoulos, Filippos [1 ,2 ]
Whalley, Nicky [1 ]
Theodoridis, Georgios [2 ]
Wilson, Ian D. [3 ]
Dunkley, Tom P. J. [1 ]
Critchlow, Susan E. [1 ]
机构
[1] Oncol iMED, Macclesfield SK10 4TG, Cheshire, England
[2] Aristotle Univ Thessaloniki, Dept Chem, Thessaloniki 54124, Greece
[3] Univ London Imperial Coll Sci Technol & Med, Dept Surg & Canc, London SW7 2AZ, England
关键词
Metabolite profiling; HILIC; Porous graphitic carbon; Ion pair chromatography; Mass spectrometry; Central carbon metabolism; CELL METABOLISM; QUANTIFICATION;
D O I
10.1016/j.chroma.2014.05.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effective analysis of polar ionic metabolites by LC-MS, such as those encountered in central carbon metabolism, represents a major problem for metabolic profiling that is not adequately addressed using strategies based on either reversed-phase or HILIC methods. Here we have compared analysis of central carbon metabolites on optimized methods using HILIC, porous graphitic carbon or ion pair chromatography (IPC) using tributyl ammonium as IF reagent. Of the 3 chromatographic approaches examined only IPC enabled us to obtain a robust analytical methodology. This system was used to profile more than a hundred endogenous metabolic intermediates in urine, serum and tissue samples. However, whilst we found IPC to be the best of the approaches examined considerable care was still needed to obtain robust data. Thus, in excess of 40 of representative biological samples were needed to "condition" a new analytical column and further 10 matrix injections were then required at the beginning of each analytical batch in order to obtain robust and reproducible chromatographic separations. An additional limitation that we have found was that, for a small number of phosphorylated and poly carboxylic acid metabolites, measurement was only possible if the analytes were present in relatively high concentrations. We also found that, whilst this methodology could be used for the analysis of both in vitro cell culture media, cell extracts, tissue, and biological fluids (blood, urine), for the best results columns should only be used to analyze a single matrix. However, despite the need for extensive column conditioning, and the manifold disadvantages resulting from the contamination of the separation system and mass spectrometer with the ion pair reagent, IPC-MS currently provides the best means of analyzing these polar, ionic and problematic metabolites. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 68
页数:9
相关论文
共 24 条
[1]   Quantification of sugars and sugar phosphates in Arabidopsis thaliana tissues using porous graphitic carbon liquid chromatography-electrospray ionization mass spectrometry [J].
Antonio, Carla ;
Larson, Tony ;
Gilday, Alison ;
Graham, Ian ;
Bergstroem, Ed ;
Thomas-Oates, Jane .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (02) :170-178
[2]   Suppression effects of carbonate on the interaction between stainless steel and phosphate groups of phosphate compounds in high-performance liquid chromatography and electrospray ionization mass spectrometry [J].
Asakawa, Yoshiki ;
Tokida, Noriaki ;
Ozawa, Chinami ;
Ishiba, Masahiko ;
Tagaya, Osamu ;
Asakawa, Naoki .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1198 :80-86
[3]   Linking energy metabolism to dysfunctions in mitochondrial respiration - A metabolomics in vitro approach [J].
Balcke, G. U. ;
Kolle, S. N. ;
Kamp, H. ;
Bethan, B. ;
Looser, R. ;
Wagner, S. ;
Landsiedel, Robert ;
van Ravenzwaay, B. .
TOXICOLOGY LETTERS, 2011, 203 (03) :200-209
[4]   An LC-MS-Based Chemical and Analytical Method for Targeted Metabolite Quantification in the Model Cyanobacterium Synechococcus sp. PCC 7002 [J].
Bennette, Nicholas B. ;
Eng, John F. ;
Dismukes, G. Charles .
ANALYTICAL CHEMISTRY, 2011, 83 (10) :3808-3816
[5]   Ultrahigh Performance Liquid Chromatography-Tandem Mass Spectrometry Method for Fast and Robust Quantification of Anionic and Aromatic Metabolites [J].
Buescher, Joerg Martin ;
Moco, Sofia ;
Sauer, Uwe ;
Zamboni, Nicola .
ANALYTICAL CHEMISTRY, 2010, 82 (11) :4403-4412
[6]   Cross-Platform Comparison of Methods for Quantitative Metabolomics of Primary Metabolism [J].
Buescher, Joerg Martin ;
Czernik, Dominika ;
Ewald, Jennifer Christina ;
Sauer, Uwe ;
Zamboni, Nicola .
ANALYTICAL CHEMISTRY, 2009, 81 (06) :2135-2143
[7]   Cancer Cell Metabolism: One Hallmark, Many Faces [J].
Cantor, Jason R. ;
Sabatini, David M. .
CANCER DISCOVERY, 2012, 2 (10) :881-898
[8]   Simultaneous quantitative analysis of metabolites using ion-pair liquid chromatography - Electrospray ionization mass spectrometry [J].
Coulier, Leon ;
Bas, Richard ;
Jespersen, Sonja ;
Verheij, Elwin ;
van der Werf, Mariet J. ;
Hankemeier, Thomas .
ANALYTICAL CHEMISTRY, 2006, 78 (18) :6573-6582
[9]   High-Throughput Quantitative Metabolomics: Workflow for Cultivation, Quenching, and Analysis of Yeast in a Multiwell Format [J].
Ewald, Jennifer Christina ;
Heux, Stephanie ;
Zamboni, Nicola .
ANALYTICAL CHEMISTRY, 2009, 81 (09) :3623-3629
[10]   Within-day reproducibility of an HPLC-MS-Based method for metabonomic analysis: Application to human urine [J].
Gika, Helen G. ;
Theodoridis, Georgios A. ;
Wingate, Julia E. ;
Wilson, Ian D. .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (08) :3291-3303