A longitudinal four-dimensional computed tomography and cone beam computed tomography dataset for image-guided radiation therapy research in lung cancer

被引:97
作者
Hugo, Geoffrey D. [1 ]
Balik, Salim [2 ]
Keall, Paul J. [3 ]
Lu, Jun [4 ]
Williamson, Jeffrey F. [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] Cleveland Clin, Cleveland, OH 44195 USA
[3] Univ Sydney, Radiat Phys Lab, Camperdown, NSW, Australia
[4] Univ Mississippi, Med Ctr, Jackson, MS 39213 USA
基金
美国国家卫生研究院;
关键词
4D imaging; computed tomography; cone beam computed tomography lung; PRIMARY TUMORS; LYMPH-NODES; RADIOTHERAPY; CT; INTERFRACTION; REQUIREMENTS; VARIABILITY;
D O I
10.1002/mp.12059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To describe in detail a dataset consisting of serial four-dimensional computed tomography (4DCT) and 4D cone beam CT (4DCBCT) images acquired during chemoradiotherapy of 20 locally advanced, nonsmall cell lung cancer patients we have collected at our institution and shared publicly with the research community. Acquisition and validation methods: As part of an NCI-sponsored research study 82 4DCT and 507 4DCBCT images were acquired in a population of 20 locally advanced nonsmall cell lung cancer patients undergoing radiation therapy. All subjects underwent concurrent radiochemotherapy to a total dose of 59.4-70.2 Gy using daily 1.8 or 2 Gy fractions. Audio-visual biofeedback was used to minimize breathing irregularity during all fractions, including acquisition of all 4DCT and 4DCBCT acquisitions in all subjects. Target, organs at risk, and implanted fiducial markers were delineated by a physician in the 4DCT images. Image coordinate system origins between 4DCT and 4DCBCT were manipulated in such a way that the images can be used to simulate initial patient setup in the treatment position. 4DCT images were acquired on a 16-slice helical CT simulator with 10 breathing phases and 3 mm slice thickness during simulation. In 13 of the 20 subjects, 4DCTs were also acquired on the same scanner weekly during therapy. Every day, 4DCBCT images were acquired on a commercial onboard CBCT scanner. An optically tracked external surrogate was synchronized with CBCT acquisition so that each CBCT projection was time stamped with the surrogate respiratory signal through in-house software and hardware tools. Approximately 2500 projections were acquired over a period of 8-10 minutes in half-fan mode with the half bow-tie filter. Using the external surrogate, the CBCT projections were sorted into 10 breathing phases and reconstructed with an in-house FDK reconstruction algorithm. Errors in respiration sorting, reconstruction, and acquisition were carefully identified and corrected. Data format and usage notes: 4DCT and 4DCBCT images are available in DICOM format and structures through DICOM-RT RTSTRUCT format. All data are stored in the Cancer Imaging Archive (TCIA, http://www.cancerimagingarchive.net/) as collection 4D-Lung and are publicly available. Discussion: Due to high temporal frequency sampling, redundant (4DCT and 4DCBCT) data at similar timepoints, oversampled 4DCBCT, and fiducial markers, this dataset can support studies in image-guided and image-guided adaptive radiotherapy, assessment of 4D voxel trajectory variability, and development and validation of new tools for image registration and motion management. c 2016 American Association of Physicists in Medicine.
引用
收藏
页码:762 / 771
页数:10
相关论文
共 22 条
[1]   Evaluation of 4-dimensional Computed Tomography to 4-dimensional Cone-Beam Computed Tomography Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy [J].
Balik, Salim ;
Weiss, Elisabeth ;
Jan, Nuzhat ;
Roman, Nicholas ;
Sleeman, William C. ;
Fatyga, Mirek ;
Christensen, Gary E. ;
Zhang, Cheng ;
Murphy, Martin J. ;
Lu, Jun ;
Keall, Paul ;
Williamson, Jeffrey F. ;
Hugo, Geoffrey D. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (02) :372-379
[2]   DAILY MEGAVOLTAGE COMPUTED TOMOGRAPHY IN LUNG CANCER RADIOTHERAPY: CORRELATION BETWEEN VOLUMETRIC CHANGES AND LOCAL OUTCOME [J].
Bral, Samuel ;
De Ridder, Mark ;
Duchateau, Michael ;
Gevaert, Thierry ;
Engels, Benedikt ;
Schallier, Denis ;
Storme, Guy .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (05) :1338-1342
[3]   Locoregional Control of Non-Small Cell Lung Cancer in Relation to Automated Early Assessment of Tumor Regression on Cone Beam Computed Tomography [J].
Brink, Carsten ;
Bernchou, Uffe ;
Bertelsen, Anders ;
Hansen, Olfred ;
Schytte, Tine ;
Bentzen, Soren M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 89 (04) :916-923
[4]   The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository [J].
Clark, Kenneth ;
Vendt, Bruce ;
Smith, Kirk ;
Freymann, John ;
Kirby, Justin ;
Koppel, Paul ;
Moore, Stephen ;
Phillips, Stanley ;
Maffitt, David ;
Pringle, Michael ;
Tarbox, Lawrence ;
Prior, Fred .
JOURNAL OF DIGITAL IMAGING, 2013, 26 (06) :1045-1057
[5]   Image Data Sharing for Biomedical Research-Meeting HIPAA Requirements for De-identification [J].
Freymann, John B. ;
Kirby, Justin S. ;
Perry, John H. ;
Clunie, David A. ;
Jaffe, C. Carl .
JOURNAL OF DIGITAL IMAGING, 2012, 25 (01) :14-24
[6]   Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy [J].
Grills, Inga S. ;
Hugo, Geoffrey ;
Kestfn, Larry L. ;
Galerani, Ana Paula ;
Chao, K. Kenneth ;
Wloch, Jennifer ;
Yan, Di .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04) :1045-1056
[7]   PET in the management of locally advanced and metastatic NSCLC [J].
Grootjans, Willem ;
de Geus-Oei, Lioe-Fee ;
Troost, Esther G. C. ;
Visser, Eric P. ;
Oyen, Wim J. G. ;
Bussink, Johan .
NATURE REVIEWS CLINICAL ONCOLOGY, 2015, 12 (07) :395-407
[8]   POTENTIAL OF ADAPTIVE RADIOTHERAPY TO ESCALATE THE RADIATION DOSE IN COMBINED RADIOCHEMOTHERAPY FOR LOCALLY ADVANCED NON-SMALL CELL LUNG CANCER [J].
Guckenberger, Matthias ;
Wilbert, Juergen ;
Richter, Anne ;
Baier, Kurt ;
Flentje, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (03) :901-908
[9]   Weekly kilovoltage cone-beam computed tomography for detection of dose discrepancies during (chemo)radiotherapy for head and neck cancer [J].
Hermans, Bregtje C. M. ;
Persoon, Lucas C. G. G. ;
Podesta, Mark ;
Hoebers, Frank J. P. ;
Verhaegen, Frank ;
Troost, Esther G. C. .
ACTA ONCOLOGICA, 2015, 54 (09) :1483-1489
[10]   Six Degrees-of-Freedom Prostate and Lung Tumor Motion Measurements Using Kilovoltage Intrafraction Monitoring [J].
Huang, Chen-Yu ;
Tehrani, Joubin Nasehi ;
Ng, Jin Aun ;
Booth, Jeremy ;
Keall, Paul .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 91 (02) :368-375