Accuracy of left ventricular function from electrocardiography-gated myocardial perfusion SPECT by MyoMetrix in Chinese

被引:0
作者
Chen, Yang-Chun [1 ]
Dai, Ruo-Zhu [2 ]
Zhang, Ke-Lian [2 ]
Dong, Yong-Da [2 ]
Zhuo, Hui-Lin [2 ]
Wang, Qing-Mu [3 ]
机构
[1] Fujian Med Univ, Quanzhou Hosp 1, Dept Nucl Med, Quanzhou 362000, Peoples R China
[2] Fujian Med Univ, Quanzhou Hosp 1, Dept Cardiol, Quanzhou 362000, Peoples R China
[3] Fujian Med Univ, Quanzhou Hosp 1, Dept Ultrasound, Quanzhou 362000, Peoples R China
关键词
Myocardial perfusion imaging; Left ventricular function; Software; EJECTION FRACTION; CLINICAL-USEFULNESS; SMALL HEARTS; ECHOCARDIOGRAPHY; TOMOGRAPHY; VOLUMES; REPRODUCIBILITY; QUANTIFICATION; VARIABILITY;
D O I
10.1007/s41365-016-0156-9
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This work was to determine threshold values for accurate measurements of left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) from electrocardiography-gated myocardial perfusion imaging (MPI) in Chinese, and these data were compared with those of echocardiography. A total of 110 patients with definite or suspected coronary artery disease were referred for both gated MPI and echocardiography within 1 week. The EDV, ESV, and EF automatically measured by MyoMetrix and echocardiography were analyzed using Bland Altman plot correlation and paired t test. The results showed that these parameters quantified by MyoMetrix software were correlated, moderately to highly, with those on echocardiography (rho, r >= 0.75, P < 0.01). However, the EF was not significantly conelated, with post-exercise MPI ESV of <15 mL or resting MPI ESV of <20 mL. At or above this ESV value, EF was underestimated by MyoMetrix (t >= 4.60, P < 0.01). In a word, a small ESV was underestimated by MyoMetrix, which could lead to EF overestimation. On the contrary, a normal or large ESV was overestimated by MyoMetrix, which led to EF underestimation.
引用
收藏
页数:6
相关论文
共 18 条
[1]   The effect of filtrating and reconstruction method on the left ventricular ejection fraction derived from GSPET: a statistical comparison of angiography and echocardiography [J].
Bitarafan, Ahmed ;
Rajabi, Hossein .
ANNALS OF NUCLEAR MEDICINE, 2008, 22 (08) :707-713
[2]   Poststress measurements of left ventricular function with gated perfusion SPECT: Comparison with resting measurements by using a same-day perfusion-function protocol [J].
Borges-Neto, S ;
Javaid, A ;
Shaw, LK ;
Kong, DF ;
Hanson, MW ;
Pagnanelli, RA ;
Ravizzini, G ;
Coleman, RE .
RADIOLOGY, 2000, 215 (02) :529-533
[3]  
Castell-Conesa J, 2004, REV ESP CARDIOL, V57, P931, DOI 10.1016/S1885-5857(06)60471-4
[4]  
Cwajg E, 1999, J NUCL MED, V40, P1857
[5]   Comparative assessment of rest and post-stress left ventricular volumes and left ventricular ejection fraction on gated myocardial perfusion imaging (MPI) and echocardiography in patients with transient ischaemic dilation on adenosine MPI: Myocardial stunning or subendocardial hypoperfusion? [J].
Emmett, Louise ;
Ng, Austin ;
Ha, Leo ;
Russo, Robert ;
Mansberg, Robert ;
Zhao, Wei ;
Chow, S. Vincent ;
Kritharides, Leonard .
JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (04) :735-742
[6]   Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts [J].
Hambye, AS ;
Vervaet, A ;
Dobbeleir, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (12) :1606-1613
[7]   Comparison of gated myocardial perfusion SPECT, echocardiography and equilibrium radionuclide ventriculography in the evaluation of left ventricle contractility [J].
Hatipoglu, Filiz ;
Burak, Zeynep ;
Omur, Ozgur .
TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2014, 42 (02) :349-357
[8]   Gated myocardial perfusion SPECT underestimates left ventricular volumes and shows high variability compared to cardiac magnetic resonance imaging -- a comparison of four different commercial automated software packages [J].
Hedeer F. ;
Palmer J. ;
Arheden H. ;
Ugander M. .
BMC Medical Imaging, 10 (1)
[9]   Gated 99mTc-MIBI single-photon emission computed tomography for the evaluation of left ventricular ejection fraction: comparison with three-dimensional echocardiography [J].
Lipiec, Piotr ;
Wejner-Mik, Paulina ;
Krzeminska-Pakula, Maria ;
Kusmierek, Jacek ;
Plachcinska, Anna ;
Szuminski, Remigiusz ;
Kapusta, Anna ;
Kasprzak, Jaroslaw D. .
ANNALS OF NUCLEAR MEDICINE, 2008, 22 (08) :723-726
[10]   Computer-assisted determination of left ventricular endocardial borders reduces variability in the echocardiographic assessment of ejection fraction [J].
Maret, Eva ;
Brudin, Lars ;
Lindstrom, Lena ;
Nylander, Eva ;
Ohlsson, Jan L. ;
Engvall, Jan E. .
CARDIOVASCULAR ULTRASOUND, 2008, 6 (1)