Continuous flow ultrasonic particle trapping in a glass capillary

被引:26
作者
Gralinski, Ian [1 ]
Raymond, Samuel [1 ]
Alan, Tuncay [1 ]
Neild, Adrian [1 ]
机构
[1] Monash Univ, Dept Mech & Aerosp Engn, Clayton, Vic 3800, Australia
基金
澳大利亚研究理事会;
关键词
HIGH-RESOLUTION ANALYSIS; COMPLEX WAVE SPECTRUM; SUSPENDED PARTICLES; ACOUSTIC RESONANCES; VISCOELASTIC MEDIUM; CYLINDRICAL-SHELL; CELLS; MANIPULATION; VIABILITY; SEPARATION;
D O I
10.1063/1.4863645
中图分类号
O59 [应用物理学];
学科分类号
摘要
Ultrasonic manipulation devices frequently exploit ultrasonic standing waves to trap particles in locations across the width of a fluidic channel or chamber. In contrast, this work describes a device, which traps particles along the length of the channel and hence at different locations along the direction of fluid flow. Actuation is achieved using a single piezoelectric transducer bonded to a borosilicate glass capillary, which defines the fluidic channel. Modes of operation have been found experimentally and through use of finite element simulation methods in which the particles can be trapped at locations away from the piezoelectric transducer allowing optimal visual access to the clumps of particles. These locations are separated by distances significantly greater than half the acoustic wavelength. When flow is introduced, a single clump is formed and optical access is unhindered by the opaque transducer allowing a method of capturing particles for multi-axial optical analysis. Applications could include determination of sample concentration or creation of concentrated samples for subsequent batch operations. (c) 2014 AIP Publishing LLC.
引用
收藏
页数:9
相关论文
共 51 条
[1]  
[Anonymous], 1965, Acoustic Streaming, DOI DOI 10.1016/B978-0-12-395662-0.50015-1
[2]  
Araz MK, 2003, ULTRASON, P1111
[3]  
Augustsson P, 2011, LAB CHIP, V11, P4152, DOI [10.1039/c1lc20637k, 10.1039/C1lc20637k]
[4]   Measuring the local pressure amplitude in microchannel acoustophoresis [J].
Barnkob, Rune ;
Augustsson, Per ;
Laurell, Thomas ;
Bruus, Henrik .
LAB ON A CHIP, 2010, 10 (05) :563-570
[5]   GENE EXPRESSION ANALYSIS OF MOUSE EMBRYONIC STEM CELLS FOLLOWING LEVITATION IN AN ULTRASOUND STANDING WAVE TRAP [J].
Bazou, Despina ;
Kearney, Roisin ;
Mansergh, Fiona ;
Bourdon, Celine ;
Farrar, Jane ;
Wride, Michael .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (02) :321-330
[6]   An automated microfluidic colourimetric sensor applied in situ to determine nitrite concentration [J].
Beaton, Alexander D. ;
Sieben, Vincent J. ;
Floquet, Cedric F. A. ;
Waugh, Edward M. ;
Bey, Samer Abi Kaed ;
Ogilvie, Iain R. G. ;
Mowlem, Matthew C. ;
Morgan, Hywel .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 156 (02) :1009-1014
[7]   Drinking water treatment processes for removal of Cryptosporidium and Giardia [J].
Betancourt, WQ ;
Rose, JB .
VETERINARY PARASITOLOGY, 2004, 126 (1-2) :219-234
[8]   Monolithically fabricated microgripper with integrated force sensor for manipulating microobjects and biological cells aligned in an ultrasonic field [J].
Beyeler, Felix ;
Neild, Adrian ;
Oberti, Stefano ;
Bell, Dominik J. ;
Sun, Yu ;
Dual, Juerg ;
Nelson, Bradley J. .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2007, 16 (01) :7-15
[9]   PROPAGATION OF ELASTIC WAVES IN A CYLINDRICAL BORE CONTAINING A FLUID [J].
BIOT, MA .
JOURNAL OF APPLIED PHYSICS, 1952, 23 (09) :997-1005
[10]   Viability of plant cell suspensions exposed to homogeneous ultrasonic fields of different energy density and wave type [J].
Böhm, H ;
Anthony, P ;
Davey, MR ;
Briarty, LG ;
Power, JB ;
Lowe, KC ;
Benes, E ;
Gröschl, M .
ULTRASONICS, 2000, 38 (1-8) :629-632