Diagnosis of occupational asthma from time point differences in serial PEF measurements

被引:33
作者
Burge, C. B. S. G. [1 ]
Moore, V. C. [1 ]
Pantin, C. F. A. [1 ]
Robertson, A. S. [1 ]
Burge, P. S. [1 ]
机构
[1] Birmingham Heartlands Hosp, Occupat Lung Dis Unit, Birmingham B9 5SS, W Midlands, England
关键词
PEAK EXPIRATORY FLOW; IDENTIFICATION; RECORDS; SYSTEM;
D O I
10.1136/thx.2009.120923
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: The diagnosis of occupational asthma requires objective confirmation. Analysis of serial measurements of peak expiratory flow (PEF) is usually the most convenient first step in the diagnostic process. A new method of analysis originally developed to detect late asthmatic reactions following specific inhalation testing is described. This was applied to serial PEF measurements made over many days in the workplace to supplement existing methods of PEF analysis. Methods: 236 records from workers with independently diagnosed occupational asthma and 320 records from controls with asthma were available. The pooled standard deviation for rest day measurements was obtained from an analysis of variance by time. Work day PEF measurements were meaned into matching 2-hourly time segments. Time points with mean work day PEF statistically lower (at the Bonferroni adjusted 5% level) than the rest days were counted after adjusting for the number of contributing measurements. Results: A minimum of four time point comparisons were needed. Records with >= 2 time points significantly lower on work days had a sensitivity of 67% and a specificity of 99% for the diagnosis of occupational asthma against independent diagnoses. Reducing the requirements to >= 1 non-waking time point difference increased sensitivity to 77% and reduced specificity to 93%. The analysis was only applicable to 43% of available records, mainly due to differences in waking times on work and rest days. Conclusion: Time point analysis complements other validated methods of PEF analysis for the diagnosis of occupational asthma. It requires shorter records than are required for the Oasys score and can identify smaller changes than other methods, but is dependent on low rest day PEF variance.
引用
收藏
页码:1032 / 1036
页数:5
相关论文
共 19 条
[1]   Effect of peak expiratory flow data quantity on diagnostic sensitivity and specificity in occupational asthma [J].
Anees, W ;
Gannon, PF ;
Huggins, V ;
Pantin, CFA ;
Burge, PS .
EUROPEAN RESPIRATORY JOURNAL, 2004, 23 (05) :730-734
[2]   Reliability of PEF diaries [J].
Anees, W ;
Huggins, V ;
Burge, PS .
THORAX, 2001, 56 (09) :742-742
[3]  
ANEES W, 2002, THESIS U BIRMINGHAM
[4]   Facilities for investigating occupational asthma in UK non-specialist respiratory departments [J].
Barber, Christopher M. ;
Naylor, Steven ;
Bradshaw, Lisa ;
Francis, Mandy ;
Harris-Roberts, Joanne ;
Rawbone, Roger ;
Curran, Andrew ;
Fishwick, David .
OCCUPATIONAL MEDICINE-OXFORD, 2008, 58 (01) :71-73
[5]  
Baur X, 1998, AM J IND MED, V33, P114
[6]   Development of an expert system for the interpretation of serial peak expiratory flow measurements in the diagnosis of occupational asthma [J].
Burge, PS ;
Pantin, CFA ;
Newton, DT ;
Gannon, PFG ;
Bright, P ;
Belcher, J ;
McCoach, J ;
Baldwin, DR ;
Burge, CBSG .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1999, 56 (11) :758-764
[7]   Standards of care for occupational asthma [J].
Fishwick, D. ;
Barber, C. M. ;
Bradshaw, L. M. ;
Harris-Roberts, J. ;
Francis, M. ;
Naylor, S. ;
Ayres, J. ;
Burge, P. S. ;
Corne, J. M. ;
Cullinan, P. ;
Frank, T. L. ;
Hendrick, D. ;
Hoyle, J. ;
Jaakkola, M. ;
Newman-Taylor, A. ;
Nicholson, P. ;
Niven, R. ;
Pickering, A. ;
Rawbone, R. ;
Stenton, C. ;
Warburton, C. J. ;
Curran, A. D. .
THORAX, 2008, 63 (03) :240-250
[8]   Occupational asthma: an assessment of diagnostic agreement between physicians [J].
Fishwick, David ;
Bradshaw, Lisa ;
Henson, Mandy ;
Stenton, Chris ;
Hendrick, David ;
Burge, Sherwood ;
Niven, Rob ;
Warburton, Chris ;
Rogers, Trevor ;
Rawbone, Roger ;
Cullinan, Paul ;
Barber, Chris ;
Pickering, Tony ;
Williams, Nerys ;
Ayres, Jon ;
Curran, Andrew D. .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2007, 64 (03) :185-190
[9]   Development of OASYS-2: A system for the analysis of serial measurement of peak expiratory flow in workers with suspected occupational asthma [J].
Gannon, PFG ;
Newton, DT ;
Belcher, J ;
Pantin, CFA ;
Burge, PS .
THORAX, 1996, 51 (05) :484-489
[10]   COMPARISON OF NORMAL AND ASTHMATIC CIRCADIAN-RHYTHMS IN PEAK EXPIRATORY FLOW-RATE [J].
HETZEL, MR ;
CLARK, TJH .
THORAX, 1980, 35 (10) :732-738