Chromatographic and thermodynamic comparison of amylose tris(3-chloro-5-methylphenylcarbamate) coated or covalently immobilized on silica in high-performance liquid chromatographic separation of the enantiomers of select chiral weak acids

被引:42
作者
Maisuradze, Mariam [1 ]
Sheklashvili, Gvantsa [1 ]
Chokheli, Ana [1 ]
Matarashvili, Iza [1 ]
Gogatishvili, Teona [1 ]
Farkas, Tivadar [2 ]
Chankvetadze, Bezhan [1 ]
机构
[1] Tbilisi State Univ, Sch Exact & Nat Sci, Inst Phys & Analyt Chem, Chavchavadze Ave 3, GE-0179 Tbilisi, Georgia
[2] Phenomenex Inc, 411 Madrid Ave, Torrance, CA 90501 USA
关键词
Coated and covalently immobilized polysaccharide-based chiral stationary phases; Reversal of enantiomer elution order; Thermodynamic parameters; Amylose tris(3-chloro-5-methylphenylcarbamate); NONAQUEOUS CAPILLARY ELECTROCHROMATOGRAPHY; VIBRATIONAL CIRCULAR-DICHROISM; TEMPERATURE-INDUCED INVERSION; STATIONARY PHASES; ELUTION ORDER; CELLULOSE; ENANTIOSEPARATION; COLUMNS; DERIVATIVES; RESOLUTION;
D O I
10.1016/j.chroma.2019.05.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The separation of enantiomers of some chiral weak acids was studied in HPLC with chiral HPLC columns prepared by coating or covalent immobilization of the same chiral selector, namely amylose tris(3-chloro-5-methylphenylcarbamate) onto silica. After screening some representatives of arylpropionic acid derivatives, coumarins and barbiturates in hydrocarbon-alcohol type mobile phases, we studied the temperature dependence of separation parameters for ketoprofen and naproxen. Instances of reversal of the enantiomer elution order were observed function of column temperature, nature of polar modifier and its content in the mobile phase, as well as between the coated and covalently immobilized versions of the columns made with more-or-less the same chiral selector. Thermodynamic parameters such as Gibb's free energy, the standard molar entropy and the standard molar enthalpy of analyte transfer from the mobile to the stationary phase were calculated in some cases in order to explain the differences observed in the enantiomer separation ability and pattern of coated and covalently immobilized columns. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:228 / 236
页数:9
相关论文
共 40 条
[31]   USEFUL CHIRAL PACKING MATERIALS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC RESOLUTION OF ENANTIOMERS - PHENYLCARBAMATES OF POLYSACCHARIDES COATED ON SILICA-GEL [J].
OKAMOTO, Y ;
KAWASHIMA, M ;
HATADA, K .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1984, 106 (18) :5357-5359
[32]  
Oliveros L, 1997, CHIRALITY, V9, P145, DOI 10.1002/(SICI)1520-636X(1997)9:2<145::AID-CHIR12>3.0.CO
[33]  
2-N
[34]  
PIRKLE WH, 1993, HRC-J HIGH RES CHROM, V16, P285
[35]   EVIDENCE FOR A TEMPERATURE-DEPENDENT REVERSAL OF THE ENANTIOSELECTIVITY IN COMPLEXATION GAS-CHROMATOGRAPHY ON CHIRAL PHASES [J].
SCHURIG, V ;
OSSIG, J ;
LINK, R .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1989, 28 (02) :194-196
[36]   Efficient Separation of Enantiomers Using Stereoregular Chiral Polymers [J].
Shen, Jun ;
Okamoto, Yoshio .
CHEMICAL REVIEWS, 2016, 116 (03) :1094-1138
[37]   Synthesis and application of immobilized polysaccharide-based chiral stationary phases for enantioseparation by high-performance liquid chromatography [J].
Shen, Jun ;
Ikai, Tomoyuki ;
Okamoto, Yoshio .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1363 :51-61
[38]   Chip-Based High-Performance Liquid Chromatography for High-Speed Enantioseparations [J].
Thurmann, Sebastian ;
Lotter, Carsten ;
Heiland, Josef J. ;
Chankvetadze, Bezhan ;
Belder, Detlev .
ANALYTICAL CHEMISTRY, 2015, 87 (11) :5568-5576
[39]   Enantioseparation of novel chiral sulfoxides on chlorinated polysaccharide stationary phases in supercritical fluid chromatography [J].
West, Caroline ;
Konjaria, Mari-Luiza ;
Shashviashvili, Natia ;
Lemasson, Elise ;
Bonnet, Pascal ;
Kakava, Rusudan ;
Volonterio, Alessandro ;
Chankvetadze, Bezhan .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1499 :174-182
[40]  
West C, 2014, CURR ANAL CHEM, V10, P99