Chromatographic and thermodynamic comparison of amylose tris(3-chloro-5-methylphenylcarbamate) coated or covalently immobilized on silica in high-performance liquid chromatographic separation of the enantiomers of select chiral weak acids

被引:42
作者
Maisuradze, Mariam [1 ]
Sheklashvili, Gvantsa [1 ]
Chokheli, Ana [1 ]
Matarashvili, Iza [1 ]
Gogatishvili, Teona [1 ]
Farkas, Tivadar [2 ]
Chankvetadze, Bezhan [1 ]
机构
[1] Tbilisi State Univ, Sch Exact & Nat Sci, Inst Phys & Analyt Chem, Chavchavadze Ave 3, GE-0179 Tbilisi, Georgia
[2] Phenomenex Inc, 411 Madrid Ave, Torrance, CA 90501 USA
关键词
Coated and covalently immobilized polysaccharide-based chiral stationary phases; Reversal of enantiomer elution order; Thermodynamic parameters; Amylose tris(3-chloro-5-methylphenylcarbamate); NONAQUEOUS CAPILLARY ELECTROCHROMATOGRAPHY; VIBRATIONAL CIRCULAR-DICHROISM; TEMPERATURE-INDUCED INVERSION; STATIONARY PHASES; ELUTION ORDER; CELLULOSE; ENANTIOSEPARATION; COLUMNS; DERIVATIVES; RESOLUTION;
D O I
10.1016/j.chroma.2019.05.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The separation of enantiomers of some chiral weak acids was studied in HPLC with chiral HPLC columns prepared by coating or covalent immobilization of the same chiral selector, namely amylose tris(3-chloro-5-methylphenylcarbamate) onto silica. After screening some representatives of arylpropionic acid derivatives, coumarins and barbiturates in hydrocarbon-alcohol type mobile phases, we studied the temperature dependence of separation parameters for ketoprofen and naproxen. Instances of reversal of the enantiomer elution order were observed function of column temperature, nature of polar modifier and its content in the mobile phase, as well as between the coated and covalently immobilized versions of the columns made with more-or-less the same chiral selector. Thermodynamic parameters such as Gibb's free energy, the standard molar entropy and the standard molar enthalpy of analyte transfer from the mobile to the stationary phase were calculated in some cases in order to explain the differences observed in the enantiomer separation ability and pattern of coated and covalently immobilized columns. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:228 / 236
页数:9
相关论文
共 40 条
[1]  
[Anonymous], 1993, Anal Methods Instrumen
[2]   High-performance liquid chromatographic enantioseparation of 1-(phenylethylamino)- or 1-(naphthylethylamino)methyl-2-naphthol analogs and a temperature-induced inversion of the elution sequence on polysaccharide-based chiral stationary phases [J].
Aranyi, Anita ;
Ilisz, Istvan ;
Pataj, Zoltan ;
Szatmari, Istvan ;
Fueloep, Ferenc ;
Peter, Antal .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (30) :4869-4876
[3]   Van't Hoff analysis in chiral chromatography [J].
Asnin, Leonid D. ;
Stepanova, Maria V. .
JOURNAL OF SEPARATION SCIENCE, 2018, 41 (06) :1319-1337
[4]   Comparative Enantiomer-Resolving Ability of Coated and Covalently Immobilized Versions of Two Polysaccharide-Based Chiral Selectors in High-Performance Liquid Chromatography [J].
Beridze, Nino ;
Tsutskiridze, Eka ;
Takaishvili, Nino ;
Farkas, Tivadar ;
Chankvetadze, Bezhan .
CHROMATOGRAPHIA, 2018, 81 (04) :611-621
[5]   3-fluoro-, 3-chloro- and 3-bromo-5-methylphenylcarbamates of cellulose and amylose as chiral stationary phases for high-performance liquid chromatographic enantioseparation [J].
Chankvetadze, B ;
Chankvetadze, L ;
Sidamonidze, S ;
Kasashima, E ;
Yashima, E ;
Okamoto, Y .
JOURNAL OF CHROMATOGRAPHY A, 1997, 787 (1-2) :67-77
[6]   High-performance liquid chromatographic enantio separations on monolithic silica columns containing a covalently attached 3,5-dimethylphenylcarbamate derivative of cellulose [J].
Chankvetadze, B ;
Ikai, T ;
Yamamoto, C ;
Okamoto, Y .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1042 (1-2) :55-60
[7]   High-performance liquid chromatographic enantioseparations on capillary columns containing crosslinked polysaccharide phenylcarbamate derivatives attached to monolithic silica [J].
Chankvetadze, Bezhan ;
Kubota, Takateru ;
Ikai, Tomoyuki ;
Yamamoto, Chiyo ;
Kamigaito, Masami ;
Tanaka, Nobuo ;
Nakanishi, Kazuki ;
Okamoto, Yoshio .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (13) :1988-1995
[8]   Recent developments on polysaccharide-based chiral stationary phases for liquid-phase separation of enantiomers [J].
Chankvetadze, Bezhan .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1269 :26-51
[9]   Enantiomer elution order reversal of fluorenylmethoxycarbonyl-isoleucine in high-performance liquid chromatography by changing the mobile phase temperature and composition [J].
Chankvetadze, L. ;
Ghibradze, N. ;
Karchkhadze, M. ;
Peng, L. ;
Farkas, T. ;
Chankvetadze, B. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (37) :6554-6560
[10]   Enantioresolution of basic pharmaceuticals using cellulose tris(4-chloro-3-methylphenylcarbamate) as chiral stationary phase and polar organic mobile phases [J].
Dossou, Katina S. S. ;
Chiap, Patrice ;
Chankvetadze, Bezhan ;
Servais, Anne-Catherine ;
Fillet, Marianne ;
Crommen, Jacques .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (44) :7450-7455