Development and validation of high-performance liquid chromatography method for analysis of b-CCT and its related substances

被引:1
作者
Huang, Caiyun [1 ]
Liu, Chunyi [2 ]
Tang, Jie [2 ]
Fang, Yi [2 ]
Ji, Linyang [1 ]
Hu, Qianyue [4 ]
Li, Qingming [3 ]
Xie, Minhao [1 ,2 ]
Chen, Zhengping [2 ]
机构
[1] Inner Mongolia Med Univ, Sch Pharmaceut Sci, Hohhot 010110, Peoples R China
[2] Jiangsu Inst Nucl Med, NHC Key Lab Nucl Med, Jiangsu Key Lab Mol Nucl Med, Wuxi 214063, Peoples R China
[3] Xuzhou Med Univ, Sch Pharm, Clin Pharm, Jiangsu Key Lab New Drug Res, Xuzhou 221004, Jiangsu, Peoples R China
[4] Nanjing Med Univ, Sch Pharm, Dept Radiopharmaceut, Nanjing 211166, Peoples R China
关键词
2 beta-Carbomethoxy-3 beta-(4-chlorophenyl)tropane; Related substances; HPLC; Method development; Analytical; Forced degradation; PET IMAGING AGENTS; DOPAMINE-TRANSPORTER; DERIVATIVES; BINDING; CONJUGATE; TROPANES; AFFINITY; LIGANDS; COCAINE; ANALOGS;
D O I
10.1016/j.arabjc.2022.103725
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Compound 2 beta-carbomethoxy-3 beta-(4-chlorophenyl)tropane (beta-CCT) is a key intermediate for the synthesis of some clinical dopamine transporter (DAT) imaging agents. Potential impurities from synthesis process of beta-CCT and degradation during storage might have detrimental effect on the final imaging agents. Thus, it is necessary to guarantee the quality of beta-CCT. In this study, a rapid, sensitive and accurate high-performance liquid chromatography (HPLC) method was devel-oped and validated for the analysis of beta-CCT and its related substances. The chromatographic sep-aration was achieved on a reverse-phase phenomenexTM Gemini C18 column with an isocratic mobile phase consisted of methanol, water and TFA (30:70:0.1 v/v/v). The flow rate was 1.0 mL/ min at 30 degrees C and samples were monitored at 220 nm. The method was validated concerning system suitability, linearity, accuracy, precision, specificity, robustness and stability. The limit of detection (LOD) and the limit of quantification (LOQ) of beta-CCT were 0.5 and 1.5 mu g/mL, respectively. The linearity range of beta-CCT was 1.5-450 mu g/mL with a good linear correlation coefficient (R-2 = 0.9999) between the peak response and concentration. Specificity investigation through forced degradation experiments displayed that beta-CCT was stable in acidic, thermal and photolytic degradation conditions, but significantly unstable in alkaline and oxidative conditions. With the developed chromatographic method, possible impurity alpha-CCT from synthetic process and potential degradation products could be well separated from beta-CCT. Good recovery and precision were manifested in the assay method. These results indicated that the present method would be suitable for not only the quality assurance of beta-CCT in regular production sample assays but also the monitoring and determination of its related substances. (c) 2022 The Author(s). Published by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页数:9
相关论文
共 29 条
[11]   Synthesis and evaluation of novel N-fluoropyridyl derivatives of tropane as potential PET imaging agents for the dopamine transporter [J].
Liu, Jingying ;
Zhu, Lin ;
Ploessl, Karl ;
Lieberman, Brian P. ;
Kung, Hank F. .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2011, 21 (10) :2962-2965
[12]   Synthesis and characterization of technetium-99m-labeled tropanes as dopamine transporter-imaging agents [J].
Meegalla, SK ;
Plossl, K ;
Kung, MP ;
Chumpradit, S ;
Stevenson, DA ;
Kushner, SA ;
McElgin, WT ;
Mozley, PD ;
Kung, HF .
JOURNAL OF MEDICINAL CHEMISTRY, 1997, 40 (01) :9-17
[13]   Synthesis of a β-CCT-lanthanide conjugate for binding the dopamine transporter [J].
Naumiec, Gregory R. ;
Lincourt, Grace ;
Clever, Jeremy P. ;
McGregor, Michael A. ;
Kovoor, Abraham ;
DeBoef, Brenton .
ORGANIC & BIOMOLECULAR CHEMISTRY, 2015, 13 (09) :2537-2540
[14]   The Organic Peroxides Instability Rating Research Based on Adiabatic Calorimetric Approaches and Fuzzy Analytic Hierarchy Process for Inherent Safety Evaluation [J].
Ni, Lei ;
Jiang, Juncheng ;
Wang, Zhirong ;
Yao, Jun ;
Song, Yuan ;
Yu, Yuan .
PROCESS SAFETY PROGRESS, 2016, 35 (02) :200-207
[15]   The role of molecular imaging in assessing degenerative parkinsonism - an updated review [J].
Nicolas, Nicastro ;
Valentina, Garibotto ;
Pierre, Burkhard R. .
SWISS MEDICAL WEEKLY, 2018, 148
[16]   Molecular Imaging of the Dopamine Transporter [J].
Palermo, Giovanni ;
Ceravolo, Roberto .
CELLS, 2019, 8 (08)
[17]   Synthesis of novel halo and tosyloxy nortropane derivatives as efficient precursors for the one-step synthesis of the dopamine transporter PET ligand [18F]FECNT [J].
Pijarowska-Kruszyna, J. ;
Jaron, A. W. ;
Kachniarz, A. ;
Kasprzak, K. ;
Kowalska, A. ;
Malkowski, B. ;
Demphel, S. ;
Dolle, F. ;
Mikolajczak, R. .
JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2014, 57 (03) :148-157
[18]   Synthesis and evaluation of novel tropane derivatives as potential PET imaging agents for the dopamine transporter [J].
Qiao, Hongwen ;
Zhu, Lin ;
Lieberman, Brian P. ;
Zha, Zhihao ;
Ploessl, Karl ;
Kung, Hank F. .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2012, 22 (13) :4303-4306
[19]   Altered levels of dopamine transporter in the frontal pole and dorsal striatum in schizophrenia [J].
Sekiguchi, Hirotaka ;
Pavey, Geoff ;
Dean, Brian .
NPJ SCHIZOPHRENIA, 2019, 5 (1)
[20]  
Shinto Ajit S, 2014, World J Nucl Med, V13, P178, DOI 10.4103/1450-1147.144818