Visual Discomfort and Visual Fatigue of Stereoscopic Displays: A Review

被引:790
作者
Lambooij, Marc [1 ]
Ijsselsteijn, Wijnand [1 ]
Fortuin, Marten [1 ,2 ,3 ]
Heynderickx, Ingrid [4 ,5 ]
机构
[1] Eindhoven Univ Technol, HTI Grp, Dept Technol Innovat Sci, NL-5600 MB Eindhoven, Netherlands
[2] Univ Appl Sci, Dept Optometry, Hogesch Utrecht, Utrecht, Netherlands
[3] City Univ London, Henry Wellcome Labs Vis Sci, Dept Optometry & Visual Sci, London, England
[4] Philips Res Labs, Eindhoven, Netherlands
[5] Delft Univ Technol, Dept Mediamat, Delft, Netherlands
关键词
DEPTH-PERCEPTION; VIRTUAL-REALITY; PERCEIVED DEPTH; ACCOMMODATION; CONVERGENCE; VERGENCE; COMFORT; FUSION; INTEGRATION; STEREOPSIS;
D O I
10.2352/J.ImagingSci.Technol.2009.53.3.030201
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Visual discomfort has been the subject of considerable research in relation to stereoscopic and autostereoscopic displays. In this paper, the importance of various causes and aspects of visual discomfort is clarified. When disparity values do not surpass a limit of 1 degrees, which still provides sufficient range to allow satisfactory depth perception in stereoscopic television, classical determinants such as excessive binocular parallax and accommodation-vergence conflict appear to be of minor importance. Visual discomfort, however, may still occur within this limit and we believe the following factors to be the most pertinent in contributing to this: (1) temporally changing demand of accommodation-vergence linkage, e.g., by fast motion in depth; (2) three-dimensional artifacts resulting from insufficient depth information in the incoming data signal yielding spatial and temporal inconsistencies; and (3) unnatural blur. In order to adequately characterize and understand visual discomfort, multiple types of measurements, both objective and subjective, are required. (C) 2009 Society for Imaging Science and Technology. [DOI: 10.2352/J.ImagingSci.Technol.2009.53.3.030201]
引用
收藏
页数:14
相关论文
共 89 条
[1]   Repeatability and validity of the PowerRefractor and the Nidek AR600-A in an adult population with healthy eyes [J].
Allen, PM ;
Radhakrishnan, H ;
O'Leary, DJ .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (03) :245-251
[2]  
[Anonymous], 1997, The eye and visual optical instruments
[3]  
Barenbrug B, 2006, ICIS '06: INTERNATIONAL CONGRESS OF IMAGING SCIENCE, FINAL PROGRAM AND PROCEEDINGS, P366
[4]   Depth-map generation by image classification [J].
Battiato, S ;
Curti, S ;
La Cascia, M ;
Tortora, M ;
Scordato, E .
THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS VI, 2004, 5302 :95-104
[5]   Visual competition [J].
Blake, R ;
Logothetis, NK .
NATURE REVIEWS NEUROSCIENCE, 2002, 3 (01) :13-23
[6]   Computer vision syndrome: A review [J].
Blehm, C ;
Vishnu, S ;
Khattak, A ;
Mitra, S ;
Yee, RW .
SURVEY OF OPHTHALMOLOGY, 2005, 50 (03) :253-262
[7]  
Blohm W., 1997, Journal of the Society for Information Display, V5, P307, DOI 10.1889/1.1985167
[8]   Ordinal configural cues combine with metric disparity in depth perception [J].
Burge, J ;
Peterson, MA ;
Palmer, SE .
JOURNAL OF VISION, 2005, 5 (06) :534-542
[9]  
COOPER JS, 2001, OPTOMETRIC OBILCAL P
[10]   The physiology of stereopsis [J].
Cumming, BG ;
DeAngelis, GC .
ANNUAL REVIEW OF NEUROSCIENCE, 2001, 24 :203-238