Behaviour of GFRP adhesive pipe joints subjected to pressure and axial loadings

被引:23
作者
Lees, JM [1 ]
机构
[1] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
基金
英国工程与自然科学研究理事会;
关键词
material; class fibres; property; strengths; adhesive bonding; testing; mechanical testing; manufacturing/processing; joints joining pipe;
D O I
10.1016/j.compositesa.2005.05.033
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The corrosion resistance of glass-fibre reinforced polymers (GFRPs) is a key advantage in pipeline applications. Adhesive bonded joints are often used in tensile resistant GFRP pipe systems and the behaviour of small-diameter GFRP tubular pipe-sections joined by using an adhesive bonded coupler is of interest. In particular, the performance of the joint when subjected to a combination of high tensile axial loads and relatively low internal pressure is investigated. Experiments are conducted where a self-equilibrating pressurisation system is used to control the internal pressure and the coupled sections are tested in tension until failure. The cases of no pressure and a 32 bar working pressure are considered. A preliminary one-dimensional linear-elastic model is developed to predict the behaviour in the early stages of loading and to quantify the influence of internal pressure on the joint performance. Based on the experimental and analytical findings, it is concluded that the most critical case for the joint is likely to be the presence of large tensile loads in absence of internal pressure. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1171 / 1179
页数:9
相关论文
共 12 条
[1]  
[Anonymous], 1983, Theory of Shell Structures
[2]  
*ASTM D, 1997, 210597 ASTM D
[3]   A REVIEW OF MULTIAXIAL BIAXIAL LOADING TESTS FOR COMPOSITE-MATERIALS [J].
CHEN, AS ;
MATTHEWS, FL .
COMPOSITES, 1993, 24 (05) :395-406
[4]  
HETENYI M, 1961, U MICHIGAN STUDIES S, V16
[5]  
Koch G. H., 2002, FHWARD01156 OFF INFR
[6]  
LEES JM, 2004, ADV POLYM COMPOSITES, P377
[7]  
*MATHW INC, 2001, MATLAB VERS 6 1 0 45
[8]   THE ANALYSIS OF ELASTIC ADHESIVE STRESSES IN BONDED LAP JOINTS IN FRP STRUCTURES [J].
PICKETT, AK ;
HOLLAWAY, L .
COMPOSITE STRUCTURES, 1985, 3 (01) :55-79
[9]   EXPERIMENTAL FAILURE STRESSES FOR +/-55-DEGREES FILAMENT WOUND GLASS-FIBER REINFORCED PLASTIC TUBES UNDER BIAXIAL LOADS [J].
SODEN, PD ;
KITCHING, R ;
TSE, PC .
COMPOSITES, 1989, 20 (02) :125-135
[10]   Biaxial test results for strength and deformation of a range of E-glass and carbon fibre reinforced composite laminates: failure exercise benchmark data [J].
Soden, PD ;
Hinton, MJ ;
Kaddour, AS .
COMPOSITES SCIENCE AND TECHNOLOGY, 2002, 62 (12-13) :1489-1514