Non-invasive monitoring of gingival crevicular fluid for estimations of blood glucose level

被引:19
作者
Yamaguchi, M [1 ]
Kawabata, Y
Kambe, S
Wårdell, K
Nystrom, FH
Naitoh, K
Yoshida, H
机构
[1] Toyama Univ, Fac Engn, Toyama 930, Japan
[2] Linkoping Univ, Dept Biomed Engn, Linkoping, Sweden
[3] Linkoping Univ, Dept Med & Care, Linkoping, Sweden
[4] Suzuken Co Ltd, Business Dev Dept, Nagoya, Aichi, Japan
[5] Nipro Co, Res & Dev Lab, Shiga, Japan
关键词
gingival crevicular fluid; non-invasive; blood glucose; capillary; diabetes;
D O I
10.1007/BF02344706
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Development of a non-invasive method for measuring the blood glucose level is an urgent necessity, and putting such a method into practical use will enable some of the physical and mental stress that patients with diabetes have to endure to be removed. To realise a non-invasive blood glucose monitor, the gingival crevicular fluid (GCF) was measured. A GCF-collecting device was developed that was designed to be disposable, biocompatible and small enough to be inserted in the gingival crevice for collection of a sub-microlitre sample of GCF. Also, a high-sensitivity glucose testing tape incorporated in the device was developed. Red laser light in a portable optical device measured the colour density of the testing tape. Standard glucose solutions were used to investigate the measurement accuracy of the GCF glucose monitor and showed a correlation coefficient of R = 0.99 (n = 20) between the optical density and the glucose levels. The GCF glucose monitor was evaluated on healthy Swedish and Japanese adults (n = 10) and both GCF glucose levels (GCFLs) and blood glucose levels (BGLs) were measured in conjunction with meal loads. The GCFLs were about 1/10-1/560 lower than the BGLs. No difference in the range of GCFLs between the Swedish and the Japanese subjects was observed. Therefore it was concluded that physique, body mass index and life-style, such as dietary habit, did not significantly influence the GCFLs. Further, the correlation coefficients of all the subjects were 0.70 and 0.88 with each group. It was suggested that GCF could be used as a method of non-invasive blood glucose measurement.
引用
收藏
页码:322 / 327
页数:6
相关论文
共 18 条
  • [1] Phantom glucose calibration models from simulated noninvasive human near-infrared spectra
    Arnold, MA
    Burmeister, JJ
    Small, GW
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (09) : 1773 - 1781
  • [2] BRILL NIELS, 1958, ACTA ODONTOL SCAND, V16, P233, DOI 10.3109/00016355809064110
  • [3] Development of an in vitro microassay for glucose quantification in submicrolitre volumes of biological fluid
    Ciantar, M
    Spratt, DA
    Newman, HN
    Wilson, M
    [J]. JOURNAL OF PERIODONTAL RESEARCH, 2002, 37 (02) : 79 - 85
  • [4] CSOREGI E, 1995, ANAL CHEM, V67, P1240
  • [5] COMPARISON OF GLUCOSE AND PROTEIN-CONTENT OF GINGIVAL FLUID FROM DIABETICS AND NONDIABETICS
    FICARA, AJ
    LEVIN, MP
    GROWER, MF
    KRAMER, GD
    [J]. JOURNAL OF PERIODONTAL RESEARCH, 1975, 10 (03) : 171 - 175
  • [6] GINSBERG BH, 1992, CLIN CHEM, V38, P1596
  • [7] NEW NONINVASIVE TRANSCUTANEOUS APPROACH TO BLOOD-GLUCOSE MONITORING - SUCCESSFUL GLUCOSE MONITORING ON HUMAN 75-G OGTT WITH NOVEL SAMPLING CHAMBER
    KAYASHIMA, S
    ARAI, T
    KIKUCHI, M
    SATO, N
    NAGATA, N
    TAKATANI, O
    ITO, N
    KIMURA, J
    KURIYAMA, T
    KANEYOSHI, A
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (08) : 752 - 757
  • [8] Kjellman O, 1970, Sven Tandlak Tidskr, V63, P11
  • [9] Noninvasive blood glucose monitoring
    Klonoff, DC
    [J]. DIABETES CARE, 1997, 20 (03) : 433 - 437
  • [10] Transdermal monitoring of glucose and other analytes using ultrasound
    Kost, Joseph
    Mitragotri, Samir
    Gabbay, Robert A.
    Pishko, Michael
    Langer, Robert
    [J]. NATURE MEDICINE, 2000, 6 (03) : 347 - 350