Glass -polyalkenoate cement: An alternative material for kyphoplasty in osteoporotic vertebral compression fractures - An ex vivo study

被引:4
|
作者
Leschinger, Tim [1 ,2 ]
Engel, Karsten [4 ]
Brueggemann, Gert Peter [2 ,4 ]
Dederer, Viktoria [1 ,2 ]
Neiss, Wolfram Friedrich [3 ]
Scheyerer, Max Joseph [1 ,2 ]
Mueller, Lars Peter [1 ,2 ]
Wegmann, Kilian [1 ,2 ]
机构
[1] Univ Med Ctr, Ctr Orthoped & Trauma Surg, Kerpenerstr 62, D-50937 Cologne, Germany
[2] Univ Cologne, Fac Med, Cologne Ctr Musculoskeletal Biomech, Cologne, Germany
[3] Univ Cologne, Inst Anat 1, Cologne, Germany
[4] German Sport Univ Cologne, Inst Biomech & Orthopaed, Cologne, Germany
关键词
PMMA; Aluminum-free glass-polyalkenoate cement; Kyphoplasty; Vertebral osteoporotic fractures; Stiffness; Adjacent vertebral body fracture; CALCIUM-PHOSPHATE CEMENT; PERCUTANEOUS VERTEBROPLASTY; BALLOON KYPHOPLASTY; IN-VIVO; BIOMECHANICAL EVALUATION; RANDOMIZED-TRIAL; MECHANICAL-PROPERTIES; INTERVERTEBRAL DISC; FORMALIN FIXATION; FINITE-ELEMENT;
D O I
10.1016/j.jmbbm.2018.03.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Adjacent vertebral body fracture is described as a risk after vertebroplasty and kyphoplasty. It may be true that this phenomenon is caused precisely because of the frequently used polymethylmethacrylate cement (PMMA), which shows a higher level of stiffness than bone material and may ultimately lead to shifting stress levels within the entire spine. The goal of the present study was to evaluate and compare the pressure distribution in the endplate of human vertebrae after kyphoplasty with PMMA and aluminum-free glass-polyalkenoate cement (gpc). For the present study, 8 fresh frozen human cadaveric vertebral bodies from the thoracolumbar junction were used. All vertebrae were augmented transpedicularly on one side with gpc and on the other side with PMMA. A loading of 600 N, 800 N and 1000 N was applied. In the data processing an individual region of interest (roi) was generated for each vertebra. The following parameters were determined for each roi: maximum force [N], maximum pressure [kPa], mean pressure [kPa], roi area [cm(2)]. We found significantly higher mean pressure values in the areas of the vertebrae augmented with PMMA, compared to the ones after augmentation with gpc (p = 0.012) when applying 1000 N. In the groups with lower forces there were no statistical relevant differences. The pressure distribution shows an advantage for gpc. A material, which does not create load concentration onto the cranial and caudal vertebral surface, could have major advantages concerning the risk of adjacent vertebral fractures. Thus the results of the 1000 N loading protocol suggest gpc being a possible alternative to ordinary PMMA cement, regarding its influence on stiffness in kyphoplasty. These and other general aspects like incorporation should be addressed and elaborated more detailed in further studies.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [41] The clinical effect of percutaneous kyphoplasty for the treatment of multiple osteoporotic vertebral compression fractures and the prevention of new vertebral fractures
    Zhai, Weifeng
    Jia, Yongwei
    Wang, Jianjie
    Cheng, Liming
    Zeng, Zhili
    Yu, Yan
    Chen, Lei
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (08): : 13473 - 13481
  • [42] Kyphoplasty for Vertebral Augmentation in the Elderly With Osteoporotic Vertebral Compression Fractures: Scenarios and Review of Recent Studies
    Bednar, Timothy
    Heyde, Christoph E.
    Bednar, Grace
    Nguyen, David
    Volpi, Elena
    Przkora, Rene
    CLINICAL THERAPEUTICS, 2013, 35 (11) : 1721 - 1727
  • [43] Effect of different bone cement distributions in percutaneous kyphoplasty on clinical outcomes for osteoporotic vertebral compression fractures: A retrospective study
    Song, Qichun
    Zhao, Yan
    Li, Dong
    Liu, Zhaoying
    Zhang, Yuankai
    Shang, Donglong
    Geng, Zilong
    Shi, Zhibin
    Fan, Li-Hong
    MEDICINE, 2023, 102 (12) : E33309
  • [44] Vertebroplasty with high-viscosity cement versus conventional kyphoplasty for osteoporotic vertebral compression fractures: a meta-analysis
    Kou, Yu-hui
    Zhang, Dian-ying
    Zhang, Jin-dong
    Han, Na
    Yang, Ming
    ANZ JOURNAL OF SURGERY, 2022, 92 (11) : 2849 - 2858
  • [45] Therapeutic effects analysis of percutaneous kyphoplasty for osteoporotic vertebral compression fractures: A multicentre study
    Yang, Huilin
    Chen, Liang
    Zheng, Zhaomin
    Yin, Guoyong
    Lu, William W.
    Wang, Genlin
    Zhu, Xuesong
    Geng, Dechun
    Zhou, Jun
    Meng, Bin
    Mao, Haiqing
    Liu, Tao
    Niu, Junjie
    Tang, Tiansi
    Zou, Jun
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2017, 11 : 73 - 77
  • [46] Interdisciplinary approach to balloon kyphoplasty in the treatment of osteoporotic vertebral compression fractures
    Franck, H
    Boszczyk, BM
    Bierschneider, M
    Jaksche, H
    EUROPEAN SPINE JOURNAL, 2003, 12 (Suppl 2) : S163 - S167
  • [47] Unilateral Versus Bilateral Balloon Kyphoplasty for Osteoporotic Vertebral Compression Fractures
    Lin, Jun
    Zhang, Lei
    Yang, Huilin
    PAIN PHYSICIAN, 2013, 16 (05) : 447 - 453
  • [48] Balloon kyphoplasty is effective in deformity correction of osteoporotic vertebral compression fractures
    Voggenreiter, G
    SPINE, 2005, 30 (24) : 2806 - 2812
  • [49] Analysis of causes of pain after kyphoplasty for osteoporotic vertebral compression fractures
    Chen Xiao-ming
    Ma Hua-song
    Wang Meng
    Yang Bin
    Yuan Wei
    CHINESE MEDICAL JOURNAL, 2013, 126 (11) : 2192 - 2194
  • [50] Functional outcomes of kyphoplasty for the treatment of osteoporotic and osteolytic vertebral compression fractures
    A. Jay Khanna
    Mary Kay Reinhardt
    Daisuke Togawa
    Isador H Lieberman
    Osteoporosis International, 2006, 17 : 817 - 826