Glass -polyalkenoate cement: An alternative material for kyphoplasty in osteoporotic vertebral compression fractures - An ex vivo study

被引:4
|
作者
Leschinger, Tim [1 ,2 ]
Engel, Karsten [4 ]
Brueggemann, Gert Peter [2 ,4 ]
Dederer, Viktoria [1 ,2 ]
Neiss, Wolfram Friedrich [3 ]
Scheyerer, Max Joseph [1 ,2 ]
Mueller, Lars Peter [1 ,2 ]
Wegmann, Kilian [1 ,2 ]
机构
[1] Univ Med Ctr, Ctr Orthoped & Trauma Surg, Kerpenerstr 62, D-50937 Cologne, Germany
[2] Univ Cologne, Fac Med, Cologne Ctr Musculoskeletal Biomech, Cologne, Germany
[3] Univ Cologne, Inst Anat 1, Cologne, Germany
[4] German Sport Univ Cologne, Inst Biomech & Orthopaed, Cologne, Germany
关键词
PMMA; Aluminum-free glass-polyalkenoate cement; Kyphoplasty; Vertebral osteoporotic fractures; Stiffness; Adjacent vertebral body fracture; CALCIUM-PHOSPHATE CEMENT; PERCUTANEOUS VERTEBROPLASTY; BALLOON KYPHOPLASTY; IN-VIVO; BIOMECHANICAL EVALUATION; RANDOMIZED-TRIAL; MECHANICAL-PROPERTIES; INTERVERTEBRAL DISC; FORMALIN FIXATION; FINITE-ELEMENT;
D O I
10.1016/j.jmbbm.2018.03.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Adjacent vertebral body fracture is described as a risk after vertebroplasty and kyphoplasty. It may be true that this phenomenon is caused precisely because of the frequently used polymethylmethacrylate cement (PMMA), which shows a higher level of stiffness than bone material and may ultimately lead to shifting stress levels within the entire spine. The goal of the present study was to evaluate and compare the pressure distribution in the endplate of human vertebrae after kyphoplasty with PMMA and aluminum-free glass-polyalkenoate cement (gpc). For the present study, 8 fresh frozen human cadaveric vertebral bodies from the thoracolumbar junction were used. All vertebrae were augmented transpedicularly on one side with gpc and on the other side with PMMA. A loading of 600 N, 800 N and 1000 N was applied. In the data processing an individual region of interest (roi) was generated for each vertebra. The following parameters were determined for each roi: maximum force [N], maximum pressure [kPa], mean pressure [kPa], roi area [cm(2)]. We found significantly higher mean pressure values in the areas of the vertebrae augmented with PMMA, compared to the ones after augmentation with gpc (p = 0.012) when applying 1000 N. In the groups with lower forces there were no statistical relevant differences. The pressure distribution shows an advantage for gpc. A material, which does not create load concentration onto the cranial and caudal vertebral surface, could have major advantages concerning the risk of adjacent vertebral fractures. Thus the results of the 1000 N loading protocol suggest gpc being a possible alternative to ordinary PMMA cement, regarding its influence on stiffness in kyphoplasty. These and other general aspects like incorporation should be addressed and elaborated more detailed in further studies.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [21] Risk factors of recompression of cemented vertebrae after kyphoplasty for osteoporotic vertebral compression fractures
    Li, Dapeng
    Wu, Yan
    Huang, Yonghui
    Augustine, Balaara
    Yue, Jiawei
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (06) : 1285 - 1290
  • [22] Kyphoplasty with an intravertebral reduction device for osteoporotic vertebral compression fractures with spinal canal encroachment
    Chi, Jia-En
    Hsu, Jia-Yuan
    Chan, Wing Yuk Ryan
    Lo, Wen-Cheng
    Chiang, Yung-Hsiao
    Lin, Jiann-Her
    FORMOSAN JOURNAL OF SURGERY, 2020, 53 (01) : 20 - +
  • [23] Vertebroplasty versus Kyphoplasty in the Treatment of Osteoporotic Vertebral Compression Fractures: A Meta-Analysis
    Daher, Mohammad
    Kreichati, Gaby
    Kharrat, Khalil
    Sebaaly, Amer
    WORLD NEUROSURGERY, 2023, 171 : 65 - 71
  • [24] Cement for Treating Osteoporotic Vertebral Compression Fractures: Finite Element Study and Clinical Outcomes
    Li, Yong-Xian
    Mo, Guo-Ye
    Zhang, Shun-Cong
    Liang, De
    Guo, Dan-Qing
    Tang, Yong-Chao
    Yuan, Kai
    Li, Da-Xing
    Guo, Hui-Zhi
    Wen, Guang-Wei
    Xu, Yue-Rong
    Luo, Pei-Jie
    Ma, Yan-Huai
    Yang, Zhi-Dong
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2018, 8 (12) : 1652 - 1657
  • [25] Early Adjacent Vertebral Fractures after Balloon Kyphoplasty for Osteoporotic Vertebral Compression Fractures
    Ko, Bong-Seong
    Cho, Kyu-Jung
    Park, Jae-Woo
    ASIAN SPINE JOURNAL, 2019, 13 (02) : 210 - 215
  • [26] Kyphoplasty in osteoporotic vertebral compression fractures - Guidelines and technical considerations
    Yohan Robinson
    Christoph E Heyde
    Peter Försth
    Claes Olerud
    Journal of Orthopaedic Surgery and Research, 6
  • [27] Results of balloon kyphoplasty in the treatment of osteoporotic vertebral compression fractures
    Voggenreiter, G.
    Brocker, K.
    Roehrl, B.
    Sadick, M.
    Obertacke, U.
    UNFALLCHIRURG, 2008, 111 (06): : 403 - 412
  • [28] Cement Augmentation of Refractory Osteoporotic Vertebral Compression Fractures Survivorship Analysis
    Gerling, Michael C.
    Eubanks, Jason D.
    Patel, Rakesh
    Whang, Peter G.
    Bohlman, Henry H.
    Ahn, Nicholas U.
    SPINE, 2011, 36 (19) : E1266 - E1269
  • [29] Comparative Analysis of Vertebroplasty and Kyphoplasty for Osteoporotic Vertebral Compression Fractures
    Bozkurt, Melih
    Kahilogullari, Gokmen
    Ozdemir, Mevci
    Ozgural, Onur
    Attar, Ayhan
    Caglar, Sukru
    Ates, Can
    ASIAN SPINE JOURNAL, 2014, 8 (01) : 27 - 34
  • [30] Extended kyphoplasty indications for stabilization of osteoporotic vertebral compression fractures
    Boszczyk, B
    Bierschneider, M
    Potulski, M
    Robert, B
    Vastmans, J
    Jaksche, H
    UNFALLCHIRURG, 2002, 105 (10): : 952 - 957