Glass -polyalkenoate cement: An alternative material for kyphoplasty in osteoporotic vertebral compression fractures - An ex vivo study

被引:4
|
作者
Leschinger, Tim [1 ,2 ]
Engel, Karsten [4 ]
Brueggemann, Gert Peter [2 ,4 ]
Dederer, Viktoria [1 ,2 ]
Neiss, Wolfram Friedrich [3 ]
Scheyerer, Max Joseph [1 ,2 ]
Mueller, Lars Peter [1 ,2 ]
Wegmann, Kilian [1 ,2 ]
机构
[1] Univ Med Ctr, Ctr Orthoped & Trauma Surg, Kerpenerstr 62, D-50937 Cologne, Germany
[2] Univ Cologne, Fac Med, Cologne Ctr Musculoskeletal Biomech, Cologne, Germany
[3] Univ Cologne, Inst Anat 1, Cologne, Germany
[4] German Sport Univ Cologne, Inst Biomech & Orthopaed, Cologne, Germany
关键词
PMMA; Aluminum-free glass-polyalkenoate cement; Kyphoplasty; Vertebral osteoporotic fractures; Stiffness; Adjacent vertebral body fracture; CALCIUM-PHOSPHATE CEMENT; PERCUTANEOUS VERTEBROPLASTY; BALLOON KYPHOPLASTY; IN-VIVO; BIOMECHANICAL EVALUATION; RANDOMIZED-TRIAL; MECHANICAL-PROPERTIES; INTERVERTEBRAL DISC; FORMALIN FIXATION; FINITE-ELEMENT;
D O I
10.1016/j.jmbbm.2018.03.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Adjacent vertebral body fracture is described as a risk after vertebroplasty and kyphoplasty. It may be true that this phenomenon is caused precisely because of the frequently used polymethylmethacrylate cement (PMMA), which shows a higher level of stiffness than bone material and may ultimately lead to shifting stress levels within the entire spine. The goal of the present study was to evaluate and compare the pressure distribution in the endplate of human vertebrae after kyphoplasty with PMMA and aluminum-free glass-polyalkenoate cement (gpc). For the present study, 8 fresh frozen human cadaveric vertebral bodies from the thoracolumbar junction were used. All vertebrae were augmented transpedicularly on one side with gpc and on the other side with PMMA. A loading of 600 N, 800 N and 1000 N was applied. In the data processing an individual region of interest (roi) was generated for each vertebra. The following parameters were determined for each roi: maximum force [N], maximum pressure [kPa], mean pressure [kPa], roi area [cm(2)]. We found significantly higher mean pressure values in the areas of the vertebrae augmented with PMMA, compared to the ones after augmentation with gpc (p = 0.012) when applying 1000 N. In the groups with lower forces there were no statistical relevant differences. The pressure distribution shows an advantage for gpc. A material, which does not create load concentration onto the cranial and caudal vertebral surface, could have major advantages concerning the risk of adjacent vertebral fractures. Thus the results of the 1000 N loading protocol suggest gpc being a possible alternative to ordinary PMMA cement, regarding its influence on stiffness in kyphoplasty. These and other general aspects like incorporation should be addressed and elaborated more detailed in further studies.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [1] Kyphoplasty in osteoporotic vertebral compression fractures - Guidelines and technical considerations
    Robinson, Yohan
    Heyde, Christoph E.
    Forsth, Peter
    Olerud, Claes
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2011, 6
  • [2] Vertebroplasty and Kyphoplasty for the Treatment of Osteoporotic Vertebral Compression Fractures
    Savage, Jason W.
    Schroeder, Gregory D.
    Anderson, Paul A.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2014, 22 (10) : 653 - 664
  • [3] Balloon kyphoplasty in patients with osteoporotic vertebral compression fractures
    Wardlaw, Douglas
    Van Meirhaeghe, Jan
    Ranstam, Jonas
    Bastian, Leonard
    Boonen, Steven
    EXPERT REVIEW OF MEDICAL DEVICES, 2012, 9 (04) : 423 - 436
  • [4] Minimally invasive cement augmentation of osteoporotic vertebral compression fractures with the new radiofrequency kyphoplasty
    Mattyasovszky, S. G.
    Kurth, A. A.
    Drees, P.
    Gemidji, J.
    Thomczyk, S.
    Kafchitsas, K.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2014, 26 (05): : 497 - 512
  • [5] Risk Factors for Cement Leakage and Adjacent Vertebral Fractures in Kyphoplasty for Osteoporotic Vertebral Fractures
    Chen, Changhong
    Fan, Pan
    Xie, Xinhui
    Wang, Yuntao
    CLINICAL SPINE SURGERY, 2020, 33 (06): : E251 - E255
  • [6] The Outcome of Radiofrequency Kyphoplasty in the Treatment of Vertebral Compression Fractures in Osteoporotic Patients
    Hegazy, Ramy
    El-Mowafi, Hesham
    Hadhood, Mahmood
    Hannout, Yasser
    Allam, Yasser
    Silbermann, Jeorg
    ASIAN SPINE JOURNAL, 2019, 13 (03) : 459 - 467
  • [7] A Comparative Analysis of the Results of Vertebroplasty and Kyphoplasty in Osteoporotic Vertebral Compression Fractures
    Kumar, Krishna
    Nguyen, Rita
    Bishop, Sharon
    NEUROSURGERY, 2010, 67 (03) : 171 - 188
  • [8] An ex vivo biomechanical comparison of a novel vertebral compression fracture treatment system to kyphoplasty
    Wilson, Derek C.
    Connolly, Ryan J.
    Zhu, Qingan
    Emery, Jeff L.
    Kingwell, Stephen P.
    Kitchel, Scott
    Cripton, Peter A.
    Wilson, David R.
    CLINICAL BIOMECHANICS, 2012, 27 (04) : 346 - 353
  • [9] Vertebroplasty and kyphoplasty-A systematic review of cement augmentation techniques for osteoporotic vertebral compression fractures compared to standard medical therapy
    Robinson, Yohan
    Olerud, Claes
    MATURITAS, 2012, 72 (01) : 42 - 49
  • [10] Bioactive poly (methyl methacrylate) bone cement for the treatment of osteoporotic vertebral compression fractures
    Zhu, Jinjin
    Yang, Shuhui
    Cai, Kaiwen
    Wang, Shuo
    Qiu, Zhiye
    Huang, Junfei
    Jiang, Guoqiang
    Wang, Xiumei
    Fang, Xiangqian
    THERANOSTICS, 2020, 10 (14): : 6544 - 6560