The normal range for inter-arm differences in blood pressure

被引:69
作者
Orme, S
Ralph, SG
Birchall, A
Lawson-Matthew, P
McLean, K
Channer, KS
机构
[1] Royal Hallamshire Hosp, Dept Cardiol, Sheffield S10 2JF, S Yorkshire, England
[2] Gen Infirm, Dept Genitourinary Med, Leeds LS1 3EX, W Yorkshire, England
[3] No Gen Hosp, Dept Hlth Care Elderly People, Sheffield S5 7AU, S Yorkshire, England
[4] Derbyshire Royal Infirm, Dept Med Elderly, Derby DE1 2QY, England
关键词
aortic dissection; blood pressure; blood pressure measurement; hypertension;
D O I
10.1093/ageing/28.6.537
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Objective: to establish the mean and normal range for the difference in simultaneous systolic and diastolic blood pressure measurements between the right and left arm. Subjects: 462 subjects, age range 20-89 years, in sinus rhythm and with no history of stroke, 98 of whom had a history of cardiovascular disease or were taking vasoactive medication. Methods: four simultaneous recordings of blood pressure in both arms were made using two automated sphygmomanometers with the subject supine after resting for 10 min. Results: inter-arm systolic and diastolic blood pressure differences show a near normal distribution of values. Some individuals had clinically important differences in systolic and diastolic blood pressure between their arms. The magnitude of these differences was not related to the mean baseline blood pressure. Linear regression analysis did not demonstrate any significant relationship between inter-arm systolic or diastolic blood pressure difference and age in patients of either sex. For systolic blood pressure the mean difference between the right and left arm was 1.1 mmHg and the normal range was -9 mmHg to 11 mmHg. For diastolic blood pressure the mean difference was 0 mmHg and the normal range -10 mmHg to 10 mmHg. Conclusion: the frequency of significant inter-arm systolic and diastolic blood pressure differences suggests that the blood pressure should be taken in both arms at the initial consultation. At subsequent visits, the arm in which measurements are taken should be recorded in the case notes. The higher of the two readings should be used to guide further management decisions.
引用
收藏
页码:537 / 542
页数:6
相关论文
共 50 条
  • [41] The detection rates of inter-arm systolic blood pressure difference vary with blood pressure levels in hypertensive patients under antihypertensive therapy
    Sun, Hanjun
    Li, Ping
    Su, Hai
    Wang, Jiwei
    Hu, Weitong
    Li, Juxiang
    Liu, Yanna
    Cheng, Xiaoshu
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 172 (03) : E419 - E420
  • [42] Prevalence and factors associated with inter-arm systolic and diastolic blood pressure differences: results from the baseline Fasa Adult’s Cohort Study (FACS)
    Ali Mouseli
    Mehdi Sharafi
    Zahra Amiri
    Azizallah Dehghan
    Elham Haghjoo
    Mohammad Ali Mohsenpour
    Mohammad Hassan Eftekhari
    Hossein Fatemian
    Omid Keshavarzian
    [J]. BMC Public Health, 24
  • [43] Relationship Between Inter-Arm Difference in Systolic Blood Pressure and Arterial Stiffness in Community-Dwelling Older Adults
    Canepa, Marco
    Milaneschi, Yuri
    Ameri, Pietro
    AlGhatrif, Majd
    Leoncini, Giovanna
    Spallarossa, Paolo
    Pontremoli, Roberto
    Brunelli, Claudio
    Strait, James B.
    Lakatta, Edward G.
    Ferrucci, Luigi
    [J]. JOURNAL OF CLINICAL HYPERTENSION, 2013, 15 (12) : 880 - 887
  • [44] Prevalence of inter-arm blood pressure difference among young healthy adults: Results from a large cross-sectional study on 3235 participants
    Essa, Rawand Abdulrahman
    Ahmed, Sirwan Khalid
    [J]. ANNALS OF MEDICINE AND SURGERY, 2022, 77
  • [45] Inter-arm Blood Pressure Difference and its Relationship with Retinal Microvascular Calibres in Young Individuals: The African-PREDICT Study
    Strauss, Michel
    Smith, Wayne
    Schutte, Aletta E.
    [J]. HEART LUNG AND CIRCULATION, 2016, 25 (08) : 855 - 861
  • [46] Inter-arm difference of systolic blood pressure measured by automated double-cuff device is associated with arterial stiffness in patients with hypertension
    Iida, Masato
    Ishiguro, Yuko
    Ueda, Norihiro
    Honjo, Haruo
    [J]. BLOOD PRESSURE MONITORING, 2020, 25 (01) : 26 - 33
  • [47] Association of an inter-arm systolic blood pressure difference with all-cause and cardiovascular mortality: A meta-analysis of cohort studies
    Li, Min
    Fan, Fangfang
    Qiu, Lin
    Ma, Wei
    Zhang, Yan
    [J]. JOURNAL OF CLINICAL HYPERTENSION, 2023, 25 (12) : 1069 - 1078
  • [48] Prognostic significance of between-arm blood pressure differences
    Agarwal, Rajiv
    Bunaye, Zerihun
    Bekele, Dagim M.
    [J]. HYPERTENSION, 2008, 51 (03) : 657 - 662
  • [49] Association of an inter-arm systolic blood pressure difference with all-cause and cardiovascular mortality: An updated meta-analysis of cohort studies
    Cao, Kaiwu
    Xu, Jingsong
    Qing Shangguan
    Hu, Weitong
    Li, Ping
    Cheng, Xiaoshu
    Su, Hai
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 189 : 211 - 219
  • [50] Inter-Arm Systolic Blood Pressure Difference and Its Risk Predictor of Chronic Kidney Disease in Community Based 10-Year Cohort Study
    Kim, Byung Ok
    Kim, Gwang Sil
    Byun, Young-Sup
    Jung, In Hyun
    Rhee, Kun Joo
    Lee, Hye Young
    [J]. CIRCULATION, 2017, 136