Blood correction reduces variability and gender differences in native myocardial T1 values at 1.5 T cardiovascular magnetic resonance - a derivation/validation approach

被引:24
作者
Nickander, Jannike [1 ,2 ]
Lundin, Magnus [1 ,2 ]
Abdula, Goran [1 ,2 ]
Sorensson, Peder [3 ]
Rosmini, Stefania [4 ]
Moon, James C. [4 ]
Kellman, Peter [5 ]
Sigfridsson, Andreas [1 ,2 ]
Ugander, Martin [1 ,2 ]
机构
[1] Karolinska Inst, Dept Clin Physiol, Stockholm, Sweden
[2] Karolinska Univ Hosp, Stockholm, Sweden
[3] Karolinska Inst, Dept Med, Unit Cardiol, Stockholm, Sweden
[4] UCL, Inst Cardiovasc Sci, London, England
[5] NHLBI, NIH, Bethesda, MD 20892 USA
基金
瑞典研究理事会;
关键词
Native T1; T1; Mapping; Post-processing; Quantification; Precision; GADOLINIUM CONTRAST AGENTS; ANDERSON-FABRY DISEASE; INVERSION-RECOVERY; CARDIAC AMYLOIDOSIS; T1-MAPPING DETECTS; MOTION CORRECTION; RELAXATION-TIMES; ADENOSINE STRESS; VOLUME; T-1;
D O I
10.1186/s12968-017-0353-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Myocardial native T1 measurements are likely influenced by intramyocardial blood. Since blood T1 is both variable and longer compared to myocardial T1, this will degrade the precision of myocardial T1 measurements. Precision could be improved by correction, but the amount of correction and the optimal blood T1 variables to correct with are unknown. We hypothesized that an appropriate correction would reduce the standard deviation (SD) of native myocardial T1. Methods: Consecutive patients (n = 400) referred for CMR with known or suspected heart disease were split into a derivation cohort for model construction (n = 200, age 51 +/- 18 years, 50% male) and a validation cohort for assessing model performance (n = 200, age 48 +/- 17 years, 50% male). Exclusion criteria included focal septal abnormalities. A Modified Look-Locker inversion recovery sequence (MOLLI, 1.5 T Siemens Aera) was used to acquire T1 and T1* maps. T1 and T1* maps were used to measure native myocardial T1, and blood T1 and T1*. A multivariate linear regression correction model was implemented using blood measurement of R1 (1/T1), R1* (1/T1*) or hematocrit. The correction model from the derivation cohort was applied to the validation cohort, and assessed for reduction in variability with the F-test. Results: Blood [LV + RV] mean R1, mean R1* and hematocrit correlated with myocardial T1 (Pearson's r, range 0.37 to 0.45, p < 0.05 for all) in both the derivation and validation cohorts respectively, suggesting that myocardial T1 measurements are influenced by intramyocardial blood. Mean myocardial native T1 did not differ between the derivation and validation cohorts (1030 +/- 42.6 ms and 1023 +/- 45.2 ms respectively, p = 0.07). In the derivation cohort, correction using blood mean R1 and mean R1* yielded a decrease in myocardial T1 SD (45.2 ms to 36.6 ms, p = 0.03). When the model from the derivation cohort was applied to the validation cohort, the SD reduction was maintained (39.3 ms, p = 0.049). This 13% reduction in measurement variability leads to a 23% reduction in sample size to detect a 50 ms difference in native myocardial T1. Conclusions: Correcting native myocardial T1 for R1 and R1* of blood improves the precision of myocardial T1 measurement by similar to 13%, and could consequently improve disease detection and reduce sample size needs for clinical research.
引用
收藏
页数:11
相关论文
共 48 条
[1]   Contrast-Enhanced Myocardial T1-Weighted Scout (Look-Locker) Imaging for the Detection of Myocardial Damages in Hypertrophic Cardiomyopathy [J].
Amano, Yasuo ;
Takayama, Morimasa ;
Kumita, Shinichiro .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (04) :778-784
[2]   T1 mapping and survival in systemic light-chain amyloidosis [J].
Banypersad, Sanjay M. ;
Fontana, Marianna ;
Maestrini, Viviana ;
Sado, Daniel M. ;
Captur, Gabriella ;
Petrie, Aviva ;
Piechnik, Stefan K. ;
Whelan, Carol J. ;
Herrey, Anna S. ;
Gillmore, Julian D. ;
Lachmann, Helen J. ;
Wechalekar, Ashutosh D. ;
Hawkins, Philip N. ;
Moon, James C. .
EUROPEAN HEART JOURNAL, 2015, 36 (04) :244-251
[3]   Saturation Recovery Single-Shot Acquisition (SASHA) for Myocardial T1 Mapping [J].
Chow, Kelvin ;
Flewitt, Jacqueline A. ;
Green, Jordin D. ;
Pagano, Joseph J. ;
Friedrich, Matthias G. ;
Thompson, Richard B. .
MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) :2082-2095
[4]   Cardiovascular magnetic resonance by non contrast T1-mapping allows assessment of severity of injury in acute myocardial infarction [J].
Dall'Armellina, Erica ;
Piechnik, Stefan K. ;
Ferreira, Vanessa M. ;
Si, Quang Le ;
Robson, Matthew D. ;
Francis, Jane M. ;
Cuculi, Florim ;
Kharbanda, Rajesh K. ;
Banning, Adrian P. ;
Choudhury, Robin P. ;
Karamitsos, Theodoros D. ;
Neubauer, Stefan .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
[5]  
DUBOIS D, 1989, NUTRITION, V5, P303
[6]   Systolic ShMOLLI myocardial T1-mapping for improved robustness to partial-volume effects and applications in tachyarrhythmias [J].
Ferreira, Vanessa M. ;
Wijesurendra, Rohan S. ;
Liu, Alexander ;
Greiser, Andreas ;
Casadei, Barbara ;
Robson, Matthew D. ;
Neubauer, Stefan ;
Piechnik, Stefan K. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
[7]   Native T1-mapping detects the location, extent and patterns of acute myocarditis without the need for gadolinium contrast agents [J].
Ferreira, Vanessa M. ;
Piechnik, Stefan K. ;
Dall'Armellina, Erica ;
Karamitsos, Theodoros D. ;
Francis, Jane M. ;
Ntusi, Ntobeko ;
Holloway, Cameron ;
Choudhury, Robin P. ;
Kardos, Attila ;
Robson, Matthew D. ;
Friedrich, Matthias G. ;
Neubauer, Stefan .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
[8]   T1 Mapping for the Diagnosis of Acute Myocarditis Using CMR Comparison to T2-Weighted and Late Gadolinium Enhanced Imaging [J].
Ferreira, Vanessa M. ;
Piechnik, Stefan K. ;
Dall'Armellina, Erica ;
Karamitsos, Theodoros D. ;
Francis, Jane M. ;
Ntusi, Ntobeko ;
Holloway, Cameron ;
Choudhury, Robin P. ;
Kardos, Attila ;
Robson, Matthew D. ;
Friedrich, Matthias G. ;
Neubauer, Stefan .
JACC-CARDIOVASCULAR IMAGING, 2013, 6 (10) :1048-1058
[9]   Non-contrast T1-mapping detects acute myocardial edema with high diagnostic accuracy: a comparison to T2-weighted cardiovascular magnetic resonance [J].
Ferreira, Vanessa M. ;
Piechnik, Stefan K. ;
Dall'Armellina, Erica ;
Karamitsos, Theodoros D. ;
Francis, Jane M. ;
Choudhury, Robin P. ;
Friedrich, Matthias G. ;
Robson, Matthew D. ;
Neubauer, Stefan .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
[10]   Native T1 Mapping in Transthyretin Amyloidosis [J].
Fontana, Marianna ;
Banypersad, Sanjay M. ;
Treibel, Thomas A. ;
Maestrini, Viviana ;
Sado, Daniel M. ;
White, Steven K. ;
Pica, Silvia ;
Castelletti, Silvia ;
Piechnik, Stefan K. ;
Robson, Matthew D. ;
Gilbertson, Janet A. ;
Rowczenio, Dorota ;
Hutt, David F. ;
Lachmann, Helen J. ;
Wechalekar, Ashutosh D. ;
Whelan, Carol J. ;
Gillmore, Julian D. ;
Hawkins, Philip N. ;
Moon, James C. .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (02) :157-165