Wind-induced vibration control of power transmission tower using pounding tuned mass damper

被引:2
作者
Tian, Li [1 ]
Gai, Xia [1 ]
机构
[1] Shandong Univ, Sch Civil Engn, Jinan 250100, Peoples R China
关键词
power transmission tower; wind-induced vibration; structural control; pounding tuned mass damper; LINE SYSTEM;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wind-induced vibration control of power transmission tower using pounding tuned mass damper is studied in the paper. The power transmission tower, which is often a high and flexible structure, is very susceptible to wind-induced vibrations. To reduce the wind-induced vibration of a transmission tower, a new type of vibration control device that pounding tuned mass damper (PTMD) is proposed in the PTMD, a limiting collar with viscoelastic material laced on the inner rim is installed to restrict the stroke of the tuned mass and to dissipate energy through collision. The pounding force is modeled based on the Hertz contact law. A 55 m tower is selected to verify the effectiveness of the PTMD. The wind field is generated based on Kaimal spectrum using harmonic superposition method. The power transmission towers without control and with the PTMD are analyzed, respectively. Results show that the PTMD is very effective in reducing the wind-induced vibration and the vibration control performance improves as the external wind load increases.
引用
收藏
页码:3693 / 3701
页数:9
相关论文
共 50 条
[31]   Wind-induced vibration of high-rise building with tuned mass damper including soil-structure interaction [J].
Liu, Ming-Yi ;
Chiang, Wei-Ling ;
Hwang, Jin-Hung ;
Chu, Chia-Ren .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2008, 96 (6-7) :1092-1102
[32]   Analytical study on wind-induced vibration of power transmission towers [J].
Yasui, H ;
Marukawa, H ;
Momomura, Y ;
Ohkuma, T .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1999, 83 :431-441
[33]   Experimental Study on Vibration Control of Suspended Piping System by Single-Sided Pounding Tuned Mass Damper [J].
Tan, Jie ;
Ho, Siu Chun Michael ;
Zhang, Peng ;
Jiang, Jinwei .
APPLIED SCIENCES-BASEL, 2019, 9 (02)
[34]   Active Tuned Mass Damper Control of Wind Turbine Nacelle/Tower Vibrations with Damaged Foundations [J].
Fitzgerald, Breiffni ;
Basu, Biswajit .
DAMAGE ASSESSMENT OF STRUCTURES X, PTS 1 AND 2, 2013, 569-570 :660-667
[35]   CONTROL OF WIND-INDUCED RESPONSE OF TRANSMISSION TOWER-LINE SYSTEM BY USING MAGNETORHEOLOGICAL DAMPERS [J].
Chen, Bo ;
Zheng, Jin ;
Qu, Weilian .
INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2009, 9 (04) :661-685
[36]   Wind Tunnel Study on Wind-Induced Vibration Responses of a UHV Transmission Tower-Line System [J].
Deng, H. Z. ;
Si, R. J. ;
Hu, X. Y. ;
Duan, C. Y. .
ADVANCES IN STRUCTURAL ENGINEERING, 2013, 16 (07) :1175-1185
[37]   Semiactive tuned mass damper for floor vibration control [J].
Setareh, Mehdi ;
Ritchey, John K. ;
Murray, Thomas M. ;
Koo, Jeong-Hoi ;
Ahmadian, Mehdi .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2007, 133 (02) :242-250
[38]   Suppression of Bridge Vibration Induced by Moving Vehicles Using Pounding Tuned Mass Dampers [J].
Yin, Xinfeng ;
Liu, Y. ;
Song, G. ;
Mo, Y. L. .
JOURNAL OF BRIDGE ENGINEERING, 2018, 23 (07)
[39]   Effect of tuned mass damper in wind-induced response of "V" plan-shaped tall building [J].
Bhattacharya, Satadru ;
Dalui, Sujit Kumar .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2022, 31 (09)
[40]   Bi-directional wind-induced vibration control of high-rise buildings using bi-directional rail variable friction pendulum-tuned mass damper [J].
Xiang, Yue ;
Tan, Ping ;
Wu, Jiurong ;
He, Hui ;
Shang, Jiying ;
Yang, Kui ;
Zheng, Zhuopeng .
ENGINEERING STRUCTURES, 2024, 303