Cellulose membrane modified with polypyrrole as an extraction device for the determination of emerging contaminants in river water with gas chromatography-mass spectrometry

被引:11
作者
de Noronha, Barbara Viero [1 ]
Bergamini, Marcio Fernando [1 ]
Marcolino Junior, Luiz Humberto [1 ]
Goncalves da Silva, Bruno Jose [1 ]
机构
[1] Univ Fed Parana UFPR, Dept Quim, Curitiba, Parana, Brazil
关键词
cellulose; emerging contaminants; gas chromatography; polypyrrole; solid-phase extraction; SOLID-PHASE EXTRACTION; WASTE-WATER; ORGANIC MICROPOLLUTANTS; LIQUID-CHROMATOGRAPHY; SOLUBLE POLYPYRROLE; PHARMACEUTICALS; SAMPLES; POLAND; BRAZIL; STATE;
D O I
10.1002/jssc.201800129
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a simple, efficient, and reusable device based on cellulose membranes modified with polypyrrole was developed to extract 14 emerging contaminants from aqueous matrices. For chemical polymerization, a low-cost cellulose membrane was immersed in 0.1 mol/L pyrrole and 0.5 mol/L ammonium persulfate for 40 min in an ice/water bath. The cellulose membranes modified with polypyrrole were accommodated in a polycarbonate holder suitable for solid-phase extraction disks. Solidphase extraction parameters that affect extraction efficiency, such as sample volume, pH, flow rate, and desorption were optimized. Subsequently, determination of target compounds was performed by gas chromatography with mass spectrometry. The linear range for analytes ranged from 0.05 to 500 mu g/L, with coefficients of determination above 0.990. The limits of quantification varied between 0.05 and 10 mu g/L, with relative standard deviations lower than 17%. The performance of the proposed cellulose membranes modified with polypyrrole device for real samples was evaluated after extraction of emerging contaminants from a river water sample from the city of Curitiba, Brazil. Bisphenol A (6.39 mu g/L), caffeine (17.83 mu g/L), and paracetamol (19.28 mu g/L) were found in these samples.
引用
收藏
页码:2790 / 2798
页数:9
相关论文
共 29 条
[1]   Solid-phase microextraction using poly(pyrrole) film and liquid chromatography with UV detection for analysis of antidepressants in plasma samples [J].
Chaves, Andrea Rodrigues ;
Chiericato Junior, Glaico ;
Costa Queiroz, Maria Eugema .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (07) :587-593
[2]   Hybrid monolith sorbent of polypyrrole-coated graphene oxide incorporated into a polyvinyl alcohol cryogel for extraction and enrichment of sulfonamides from water samples [J].
Chullasat, Kochaporn ;
Nurerk, Piyaluk ;
Kanatharana, Proespichaya ;
Kueseng, Pamornrat ;
Sukchuay, Thanyaporn ;
Bunkoed, Opas .
ANALYTICA CHIMICA ACTA, 2017, 961 :59-66
[3]   Emerging pollutants in wastewater: A review of the literature [J].
Deblonde, Tiphanie ;
Cossu-Leguille, Carole ;
Hartemann, Philippe .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2011, 214 (06) :442-448
[4]   Facile preparation of magnetic molecularly imprinted polymers for the selective extraction and determination of dexamethasone in skincare cosmetics using HPLC [J].
Du, Wei ;
Zhang, Bilin ;
Guo, Pengqi ;
Chen, Guoning ;
Chang, Chun ;
Fu, Qiang .
JOURNAL OF SEPARATION SCIENCE, 2018, 41 (11) :2441-2452
[5]   Determination of fluoxetine and norfluoxetine enantiomers in human plasma by polypyrrole-coated capillary in-tube solid-phase microextraction coupled with liquid chromatography-fluorescence detection [J].
Goncalves Silva, Bruno Jose ;
Lancas, Fernando Mauro ;
Costa Queiroz, Maria Eugenia .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (49) :8590-8597
[6]   Multiresidue analysis of 88 polar organic micropollutants in ground, surface and wastewater using online mixed-bed multilayer solid-phase extraction coupled to high performance liquid chromatography-tandem mass spectrometry [J].
Huntscha, Sebastian ;
Singer, Heinz P. ;
McArdell, Christa S. ;
Frank, Carolin E. ;
Hollender, Juliane .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1268 :74-83
[7]  
Ide A., 2013, REV BRASILEIRA RECUR, V18, P201, DOI [10.21168/rbrh.v18n2.p201-211, DOI 10.21168/RBRH.V18N2.P201-211]
[8]   Ultrasonic-microwave method in preparation of polypyrrole-coated magnetic particles for vitamin D extraction in milk [J].
Jiao, Zhe ;
Zhang, Yan ;
Fan, Hongbo .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1457 :7-13
[9]   SYNTHESIS OF SOLUBLE POLYPYRROLE OF THE DOPED STATE IN ORGANIC-SOLVENTS [J].
LEE, JY ;
KIM, DY ;
KIM, CY .
SYNTHETIC METALS, 1995, 74 (02) :103-106
[10]   Conducting polymers in environmental analysis [J].
Li, Xiang ;
Wang, Yonghua ;
Yang, Xin ;
Chen, Jianmin ;
Fu, Hongbo ;
Cheng, Tiantao .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 39 :163-179