Long-Term Performance of the Attain Model 4193 Left Ventricular Lead

被引:4
作者
Ben Johnson, W. [1 ]
Abraham, William T. [2 ]
Young, James B. [3 ]
Wheelan, Kevin [4 ]
Smith, Andrew L. [5 ]
Chang, Yanping [6 ]
Brinkman, Paula [6 ]
机构
[1] Iowa Heart Ctr, Des Moines, IA 50314 USA
[2] Ohio State Univ, Ctr Heart, Columbus, OH 43210 USA
[3] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[4] Baylor Univ, Med Ctr, Dallas, TX USA
[5] Emory Univ, Crawford Long Hosp, Atlanta, GA 30365 USA
[6] Medtronic Inc, Minneapolis, MN USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2009年 / 32卷 / 09期
关键词
cardiac resynchronization therapy; long-term performance; left ventricular lead; CHRONIC HEART-FAILURE; CARDIAC-RESYNCHRONIZATION THERAPY; PACING LEADS; IMPLANTATION; EXPERIENCE; TRIAL;
D O I
10.1111/j.1540-8159.2009.02451.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Methods: The Attain Model 4193 LV lead (Medtronic, Inc, Minneapolis MN, USA) was successfully implanted in 1,070 patients with 286 patients completing 3 years of follow-up. Clinical data were collected at pre-implant, implant, and at 6-month intervals for 3 years. Results: Over 3 years, the mean chronic pacing threshold ranged from 1.9 V to 2.1 V, the mean R-wave sensing amplitudes ranged between 13.6 mV and 15.0 mV, and the mean pacing impedance ranged between 562 ohms and 590 ohms. Additionally, the observed freedom from first post-implant LV-lead-related complications was 90.4%. Of 1,070 total patients, 82 experienced 89 LV-lead-related adverse events requiring invasive interventions or resulting in the termination of the CRT therapy. The LV lead was repositioned in 31 patients, replaced in 21 patients, and explanted/capped in four patients. There were no deaths related to the LV lead during implantation or during the follow-up period. Conclusions: The data suggest that the 4193 LV lead is safe and effective over time. The LV lead electrical measurements remained stable through follow-up, demonstrating reliable long-term performance within the recommended value range at 36 months and had an acceptable complication rate. (PACE 2009; 32:1111-1116).
引用
收藏
页码:1111 / 1116
页数:6
相关论文
共 15 条
  • [1] Cardiac resynchronization in chronic heart failure
    Abraham, WT
    Fisher, WG
    Smith, AL
    Delurgio, DB
    Leon, AR
    Loh, E
    Kocovic, DZ
    Packer, M
    Clavell, AL
    Hayes, DL
    Ellestad, M
    Messenger, J
    Trupp, RJ
    Underwood, J
    Pickering, F
    Truex, C
    McAtee, P
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) : 1845 - 1853
  • [2] Six year experience of transvenous left ventricular lead implantation for permanent biventricular pacing in patients with advanced heart failure: technical aspects
    Alonso, C
    Leclercq, C
    d'Allonnes, FR
    Pavin, D
    Victor, F
    Mabo, P
    Daubert, JC
    [J]. HEART, 2001, 86 (04) : 405 - 410
  • [3] Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure
    Bristow, MR
    Saxon, LA
    Boehmer, J
    Krueger, S
    Kass, DA
    De Marco, T
    Carson, P
    DiCarlo, L
    DeMets, D
    White, BG
    DeVries, DW
    Feldman, AM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) : 2140 - 2150
  • [4] Longer-term effects of cardiac resynchronization therapy on mortality in heart failure [the CArdiac REsynchronization-Heart Failure (CARE-HF) trial extension phase]
    Cleland, John G. F.
    Daubert, Jean-Claude
    Erdmann, Erland
    Freemantle, Nick
    Gras, Daniel
    Kappenberger, Lukas
    Tavazzi, Luigi
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 (16) : 1928 - 1932
  • [5] Short and long-term single-centre experience with an S-shaped unipolar lead for left ventricular pacing
    Fatemi, M
    Etienne, Y
    Gilard, M
    Mansourati, J
    Blanc, JJ
    [J]. EUROPACE, 2003, 5 (02): : 207 - 211
  • [6] Gregoratos G, 2002, J CARDIOVASC ELECTR, V13, P1183
  • [7] Hasdemir C, 2007, ANATOL J CARDIOL, V7, P53
  • [8] Long-term performance of active-fixation pacing leads: A prospective study
    Kistler, PM
    Liew, G
    Mond, HG
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (03): : 226 - 230
  • [9] Safety of transvenous cardiac resynchronization system implantation in patients with chronic heart failure -: Combined results of over 2,000 patients from a multicenter study program
    León, AR
    Abraham, WT
    Curtis, AB
    Daubert, JP
    Fisher, WG
    Gurley, J
    Hayes, DL
    Lieberman, R
    Petersen-Stejskal, S
    Wheelan, K
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (12) : 2348 - 2356
  • [10] Cardiac resynchronization with sequential biventricular pacing for the treatment of moderate-to-severe heart failure
    León, AR
    Abraham, WT
    Brozena, S
    Daubert, JP
    Fisher, WG
    Gurley, JC
    Liang, CS
    Wong, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (12) : 2298 - 2304