Electrochemical deposition of silver and gold from cyanide leaching solutions

被引:31
作者
Reyes-Cruz, V [1 ]
Ponce-de-León, C [1 ]
González, I [1 ]
Oropeza, MT [1 ]
机构
[1] Univ Autonoma Metropolitana Iztapalapa, Dept Quim, Mexico City 09340, DF, Mexico
关键词
silver cyanide; gold cyanide; copper cyanide; electrochemical recovery; cyanide leaching; RVC electrode; electrodeposition;
D O I
10.1016/S0304-386X(02)00083-X
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
A systematic voltammetric study developed in this work allows the determination of the potential range at which the selective deposition of gold and silver is carried out in the presence of a high content of copper. As a first approach, laboratory solutions prepared with a high content of cyanide and copper and low values of gold and silver are used; later, the methodology is applied to leaching solutions of industrial origin. The chemical speciation and microelectrolysis studies showed that copper deposition occurs at more negative potentials than deposition of gold and silver. Also, the voltammetric study of a cyanide solution containing low concentrations of Au(I) and Ag(I), free of and with high concentration of Cu(I) was carried out. The study shows the potential range at which Au(I) and Ag(I) are reduced despite the high concentration of the Cu(I) ions. The deposition of gold and silver was not interfered with by the high concentration of Cu(I) ions when the leaching solution was electrolyzed in a laboratory electrochemical reactor FM01-LC with a reticulated vitreous carbon (RVC) cathode. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:187 / 203
页数:17
相关论文
共 26 条
[1]  
Bennion DN., 1972, J APPL ELECTROCHEM, V2, P113
[2]  
BROWN CJ, 1994, J APPL ELECTROCHEM, V24, P95
[3]   LOCAL MASS-TRANSPORT EFFECTS IN THE FMOI LABORATORY ELECTROLYZER [J].
BROWN, CJ ;
PLETCHER, D ;
WALSH, FC ;
HAMMOND, JK ;
ROBINSON, D .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1992, 22 (07) :613-619
[4]   STUDIES OF SPACE-AVERAGED MASS-TRANSPORT IN THE FM01-LC LABORATORY ELECTROLYZER [J].
BROWN, CJ ;
PLETCHER, D ;
WALSH, FC ;
HAMMOND, JK ;
ROBINSON, D .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1993, 23 (01) :38-43
[5]  
CAROLI S, 1978, TABLES STANDARD ELEC
[6]  
Chrzanowski W, 1996, J APPL ELECTROCHEM, V26, P385, DOI 10.1007/BF00251323
[7]   PERCOLATING POROUS-ELECTRODE .3. DIFFERENCE IN METAL-SOLUTION POTENTIAL IN ELECTRODE WITH LIMITING CURRENT [J].
COEURET, F .
ELECTROCHIMICA ACTA, 1976, 21 (03) :203-213
[8]   STUDY OF EFFECTIVENESS OF FIXED FLOW-THROUGH ELECTRODES [J].
COEURET, F ;
HUTIN, D ;
GAUNAND, A .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1976, 6 (05) :417-423
[9]   HYDROMETALLURGY OF PRECIOUS METALS RECOVERY [J].
FLEMING, CA .
HYDROMETALLURGY, 1992, 30 (1-3) :127-162
[10]  
JHA MC, 1984, P 1 INT S PREC MET R, P1