Investigation of position sensitive avalanche photodiodes for a new high-resolution PET detector design

被引:45
作者
Levin, CS [1 ]
Foudray, AMK
Olcott, PD
Habte, F
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
[2] Univ Calif San Diego, Dept Phys, La Jolla, CA 92037 USA
[3] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
avalanche photodiodes; photodetectors; positron emission tomography (PET); scintillation detectors;
D O I
10.1109/TNS.2004.830112
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We are developing a high-resolution PET detector design with a goal of nearly complete scintillation light collection in less than or equal to 1 mm width, greater than or equal to 20 mm effective thickness LSO crystals. The design uses position sensitive avalanche photodiodes in novel layered configurations that significantly improve the light collection aspect ratio. To reduce design complexity and dead area we are investigating the use of 1 mm thick sheets of LSO in addition to discrete crystal rods, and the use of PSAPDs which require only four readout channels per device. The raw spatial response of a 1 mm thick crystal sheet coupled to a PSAPD exhibits a compressed dynamic range compared to that observed with discrete crystals. Measurements with the proposed configurations using Na-22. irradiation achieved 10%-13% FWHM energy resolution at 511 keV and 2 ns coincidence time resolution. 1 mm width crystals with a saw cut surface finish an no inter-crystal reflector were well resolved in flood images.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 14 条
  • [1] Chatziioannou AF, 1999, J NUCL MED, V40, P1164
  • [2] FREIFELDER R, 2001, P 2001 IEEE NUCL SCI, V3, P1241
  • [3] A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals
    Jeavons, AP
    Chandler, RA
    Dettmar, CAR
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 468 - 473
  • [4] JOUNG J, 2001, P IEEE NUCL SCI S C, V2, P1137
  • [5] Design of a high-resolution and high-sensitivity scintillation crystal array for PET with nearly complete light collection
    Levin, CS
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2236 - 2243
  • [6] LEWIN CS, 2003, P 2002 IEEE NUCL SCI, V3, P1751
  • [7] MARRIOTT CJ, 1994, J NUCL MED, V35, P1390
  • [8] Performance characteristics of micro crystal element (MiCE) detectors
    Miyaoka, RS
    Kohlmyer, SG
    Lewellen, TK
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1403 - 1407
  • [9] FEASIBILITY STUDY OF AN AVALANCHE PHOTODIODE READOUT FOR A HIGH-RESOLUTION PET WITH NSEC TIME RESOLUTION
    SCHMELZ, C
    BRADBURY, SM
    HOLL, I
    LORENZ, E
    RENKER, D
    ZIEGLER, S
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1080 - 1084
  • [10] Large-area APDs and monolithic APD Arrays
    Shah, KS
    Farrell, R
    Grazioso, R
    Myers, R
    Cirignano, L
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) : 2352 - 2356