Estimation of Hydrolysis Parameters in Full-Scale Anerobic Digesters

被引:223
作者
Batstone, D. J. [1 ]
Tait, S. [1 ]
Starrenburg, D. [2 ]
机构
[1] Univ Queensland, Adv Water Management Ctr, St Lucia, Qld 4072, Australia
[2] Brisbane Cty Council, Brisbane, Qld 4000, Australia
关键词
hydrolysis; activated sludge; SRT; anerobic; thermal hydrolysis; ADM1; KINETICS;
D O I
10.1002/bit.22163
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In hydrolysis-limited anerobic systems, the key parameters describing degradation are degradability extent (f(d)), and the lumped apparent first order coefficient (k(hyd)). These are often measured in biological methane potential (BMP) tests. Using modern techniques, it should also be Possible to estimate these parameters in full-scale systems, especially where inputs are dynamic, In this study, we evaluated f(d) and k(hyd) values and uncertainty based on nonlinear parameter estimation from (i) BMP tests and (ii) effluent gas and solids from two full-scale digesters fed with highly variable feed flows and concentrations (up to 6 kg COD m(-3) day(-1)). The substrate was thermally hydrolyzed activated sludge, and the inoculum for BMP tests was front the full-scale digesters. While identifiability of both parameter, in the BIMP tests was generally good, Only fd Could tic well identified using continuous data. For k(hyd) Using Continuous data, normally only a lower limit could be found (upper was unbounded). In addition, parameters as estimated on different outputs (VS and gasflow) and two different digesters were consistent, with an f(d) value of 0.45-0.55, and a k(hyd) value of >5 day(-3). Gradual changes in f(d) over the 450 days could be related to upstream changes. f(d) values as estimated in BMP tests were consistent (if conservative) with continuous estimates, with a f(d) in BMP of 0.4-0.5. k(hyd) values were an order of magnitude lower (0.15-0.25 day(-1) vs. >5 day(-1)), and this translated to very poor model performance when BMP-estimated values Were used in the continuous model. This means that while BMP testing may be used for project feasibility analysis, values obtained should not be used for dynamic modeling. The parameter confidence regions found were highly nonlinear, especially for continuous systems, indicating that iterative or sampling techniques are required for an estimate of real parameter uncertainly.
引用
收藏
页码:1513 / 1520
页数:8
相关论文
共 10 条
[1]   Assessment of the anaerobic biodegradability of macropollutants [J].
Angelidaki I. ;
Sanders W. .
Re/Views in Environmental Science & Bio/Technology, 2004, 3 (2) :117-129
[2]  
[Anonymous], 1992, STAND METH EX WAT WA
[3]  
[Anonymous], 2002, WATER INTELL ONLINE, DOI DOI 10.2166/9781780403052
[4]   Kinetics of thermophilic, anaerobic oxidation of straight and branched chain butyrate and valerate [J].
Batstone, DJ ;
Pind, PF ;
Angelidaki, I .
BIOTECHNOLOGY AND BIOENGINEERING, 2003, 84 (02) :195-204
[5]  
Dochain D., 2001, Dynamic modelling and estimation in wastewater treatment processes
[6]   Decreasing activated sludge thermal hydrolysis temperature reduces product colour, without decreasing degradability [J].
Dwyer, Jason ;
Starrenbury, Daniel ;
Tait, Stephan ;
Barr, Keith ;
Batstone, Damien J. ;
Lant, Paul .
WATER RESEARCH, 2008, 42 (18) :4699-4709
[7]  
GOSSETT JM, 1982, J ENV ENG DIV-ASCE, V108, P1101
[8]   BIOASSAY FOR MONITORING BIOCHEMICAL METHANE POTENTIAL AND ANAEROBIC TOXICITY [J].
OWEN, WF ;
STUCKEY, DC ;
HEALY, JB ;
YOUNG, LY ;
MCCARTY, PL .
WATER RESEARCH, 1979, 13 (06) :485-492
[9]   KINETICS OF ANAEROBIC TREATMENT - A CRITICAL-REVIEW [J].
PAVLOSTATHIS, SG ;
GIRALDOGOMEZ, E .
CRITICAL REVIEWS IN ENVIRONMENTAL CONTROL, 1991, 21 (5-6) :411-490
[10]  
TAKACS I, 2008, THESIS GHENT U GHENT