Comparison of two- and three-dimensional transesophageal echocardiography in patients undergoing atrial septal closure with the amplatzer septal occluder

被引:15
作者
Tamborini, G
Pepi, M
Susini, F
Trabattoni, D
Maltagliati, A
Berna, G
Onorato, E
Bartorelli, AL
机构
[1] Univ Milan, Ctr Cardiol Monzino, IRCCS, Inst Cardiol, I-20138 Milan, Italy
[2] Clin San Rocco, Div Cardiol, Ome, Italy
关键词
D O I
10.1016/S0002-9149(02)02695-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Two-dimensional (2-D) and 3-dimensional (3-D) transesophageal echocardiography (TEE) using new 3-D software was performed in 30 patients who underwent percutaneous closure of ostium secundum atrial septal defects. Two-dimensional TEE significantly underestimated the balloon-stretched diameters, whereas no significant difference was found between the invasive measurement and the 3-D major diameter of the atrial septal defect. Three-dimensional TEE better delineated the complex shape. and dynamic changes of the defect, confirmed the correct opening of the device and revealed its spatial relations with adjacent cardiac structures.
引用
收藏
页码:1025 / +
页数:5
相关论文
共 20 条
[1]   Influence of atrial septal defect anatomy in patient selection and assessment of closure with the Cardioseal device - A three-dimensional transoesophageal echocardiographic reconstruction [J].
Acar, P ;
Saliba, Z ;
Bonhoeffer, P ;
Aggoun, Y ;
Bonnet, D ;
Sidi, D ;
Kachaner, J .
EUROPEAN HEART JOURNAL, 2000, 21 (07) :573-581
[2]   Assessment of the geometric profile of the Amplatzer and Cardioseal septal occluders by three dimensional echocardiography [J].
Acar, P ;
Saliba, Z ;
Bonhoeffer, P ;
Sidi, D ;
Kachaner, J .
HEART, 2001, 85 (04) :451-453
[3]   Surgical validation and implications for transcatheter closure of quantitative echocardiographic evaluation of atrial septal defect [J].
Chau, AKT ;
Leung, MP ;
Yung, TC ;
Chan, KN ;
Cheung, YF ;
Chiu, SW .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (09) :1124-1130
[4]   Secundum atrial septal defect is a dynamic three-dimensional entity [J].
Dall'Agata, A ;
McGhie, J ;
Taams, MA ;
Cromme-Dijkhuis, AH ;
Spitaels, SEC ;
Breburda, CSM ;
Roelandt, JRTC ;
Bogers, AJJC .
AMERICAN HEART JOURNAL, 1999, 137 (06) :1075-1081
[5]   Transcatheter closure of secundum atrial septal defects with the new self-centering Amplatzer Septal Occluder [J].
Fischer, G ;
Kramer, HH ;
Stieh, J ;
Harding, P ;
Jung, O .
EUROPEAN HEART JOURNAL, 1999, 20 (07) :541-549
[6]  
Franke A, 1997, CIRCULATION, V96, P323
[7]  
Handke M, 2001, Eur J Echocardiogr, V2, P46, DOI 10.1053/euje.2000.0064
[8]   Transesophageal echocardiographic results of catheter closure of atrial septal defect in children and adults using the Amplatzer device [J].
Hijazi, ZM ;
Cao, QL ;
Patel, HT ;
Rhodes, J ;
Hanlon, KM .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (11) :1387-+
[9]   MEASUREMENT OF ATRIAL SEPTAL-DEFECT DURING CARDIAC-CATHETERIZATION - EXPERIMENTAL AND CLINICAL RESULTS [J].
KING, TD ;
THOMPSON, SL ;
MILLS, NL .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (03) :537-542
[10]   Assessment of atrial septal defect morphology by transthoracic three dimensional echocardiography using standard grey scale and Doppler myocardial imaging techniques: comparison with magnetic resonance imaging and intraoperative findings [J].
Lange, A ;
Walayat, M ;
Turnbull, CM ;
Palka, P ;
Mankad, P ;
Sutherland, GR ;
Godman, MJ .
HEART, 1997, 78 (04) :382-389