Fast three-dimensional k-space trajectory design using missile guidance ideas

被引:17
作者
Mir, R [1 ]
Guesalaga, A [1 ]
Spiniak, J [1 ]
Guarini, M [1 ]
Irarrazaval, P [1 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Elect Engn, Santiago, Chile
关键词
MRI; k-space; missile guidance; 3D trajectory design; fast imaging;
D O I
10.1002/mrm.20163
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional (3D) k-space trajectories are needed to acquire volumetric images in MRI. While scan time is determined by the trajectory efficiency, image quality and distortions depend on the shape of the trajectories. There are several 3D trajectory strategies for sampling the k-space using rectilinear or curve schemes. Since there is no evidence about their optimality in terms of image quality and acquisition time, a new design method based on missile guidance ideas is explored. Since air-to-air missile guidance shares similar goals and constraints with the problem of k-space trajectory design, a control approach for missiles is used to design a 3D trajectory. The k-space is divided into small cubes, and each one is treated as a target to be sampled. The main goal is to cover the entire space as quickly and efficiently as possible, with good performance under different conditions. This novel design method is compared to other trajectories using simulated and real data. As an example, a trajectory that requires 0.11 times the number of shots needed by the cylindrical 3DFT acquisition was designed. This trajectory requires more shots (1.66 times) than the stack of spirals, but behaves better under nonideal conditions, such as off-resonance and motion. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:329 / 336
页数:8
相关论文
共 24 条
[1]   Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory [J].
Barger, AV ;
Block, WF ;
Toropov, Y ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :297-305
[2]  
BLAKELOCK JH, 1991, MISSILE CONTROL SYST, P229
[3]   Fast three dimensional sodium imaging [J].
Boada, FE ;
Gillen, JS ;
Shen, GX ;
Chang, SY ;
Thulborn, KR .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) :706-715
[4]   FAST 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING [J].
IRARRAZABAL, P ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :656-662
[5]   Inhomogeneity correction using an estimated linear field map [J].
Irarrazabal, P ;
Meyer, CH ;
Nishimura, DG ;
Macovski, A .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) :278-282
[6]   Flow properties of fast three-dimensional sequences for MR angiography [J].
Irarrázaval, P ;
Santos, JM ;
Guarini, M ;
Nishimura, D .
MAGNETIC RESONANCE IMAGING, 1999, 17 (10) :1469-1479
[7]   TWISTING RADIAL LINES WITH APPLICATION TO ROBUST MAGNETIC-RESONANCE-IMAGING OF IRREGULAR FLOW [J].
JACKSON, JI ;
NISHIMURA, DG ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (01) :128-139
[8]   SELECTION OF A CONVOLUTION FUNCTION FOR FOURIER INVERSION USING GRIDDING [J].
JACKSON, JI ;
MEYER, CH ;
NISHIMURA, DG ;
MACOVSKI, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :473-478
[9]   Dynamic MR-imaging with radial scanning, a post-acquisition keyhole approach [J].
Lethmate, R ;
Wajer, FTAW ;
Crémillieux, Y ;
van Ormondt, D ;
Graveron-Demilly, D .
EURASIP JOURNAL ON APPLIED SIGNAL PROCESSING, 2003, 2003 (05) :405-412
[10]   REDUCED PHASE-ENCODING IN SPECTROSCOPIC IMAGING [J].
MAUDSLEY, AA ;
MATSON, GB ;
HUGG, JW ;
WEINER, MW .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :645-651