In Vitro Evaluation of Mechanical Properties of Segmented Esophageal Self-Expandable Metal Stents: Innovative Test Methods Are Needed

被引:5
|
作者
Buerger, Martin [1 ]
Herbold, Till [2 ]
Lange, Sven [3 ]
Berlth, Felix [4 ]
Plum, Patrick Sven [4 ]
Schramm, Christoph [1 ]
Kleinert, Robert [4 ]
Goeser, Tobias [1 ]
Bruns, Christiane Josephine [4 ]
Chon, Seung-Hun [4 ]
机构
[1] Univ Hosp Cologne, Dept Gastroenterol & Hepatol, Cologne, Germany
[2] Rhein Westfal TH Aachen, Dept Gen Visceral & Transplantat Surg, Aachen, Germany
[3] Bess Pro GmbH, Berlin, Germany
[4] Univ Hosp Cologne, Dept Gen Visceral & Canc Surg, Cologne, Germany
来源
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES | 2019年 / 29卷 / 09期
关键词
esophageal stent; in vitro mechanical properties; esophageal cancer; segmented self-expanding metal stent; FORCE;
D O I
10.1089/lap.2019.0173
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Self-expanding metal stents (SEMSs) in different geometric shapes are well established treatment options in diseases of the esophagus. Mechanical properties and stent design may have an impact on patient comfort, migration rate, and removability. In this in vitro study, we evaluated mechanical properties of three segmented SEMSs (segSEMSs) for the esophagus with regard to distinct stent sections. Materials and Methods: Radial forces were measured using a testing method distinguishing between circumferential radial and local radial force. The center parts of the segSEMSs were measured for circumferential radial forces without being affected by the flared ends. Axial forces were measured at 20 degrees bending. Results: Circumferential radial force measurements over the full stent length showed substantial differences against measurements of the center parts of the stents as the flared ends falsify test results by up to 53%. Although circumferential radial forces of the center parts were about the same (<10% variances) for all segSEMSs, local radial forces showed considerable differences of up to 26%. One segSEMS showed high axial forces, whereas the other two only needed half of the force (up to 53%) to be bent to 20 degrees. Conclusion: Flared ends of segSEMSs have a substantial impact on radial force measurements and therefore alter test results, confirmed by our separated center part test of segSEMSs. Our innovative setup whereby we compressed the stent in an asymmetric manner (local radial force) and evaluated sections of stents separately, indeed revealed differences to circumferential measurements, leading to a more in-depth knowledge of stent characteristics.
引用
收藏
页码:1168 / 1173
页数:6
相关论文
共 7 条
  • [1] Self-Expandable Metal Stents in Esophageal Cancer in a High HIV Prevalence Area: A Survival Analysis and Evaluation of Prediction Scores
    Loots, Emil
    Anderson, Frank
    Clarke, Damian L.
    Mulder, Chris J. J.
    Madiba, Thandinkosi E.
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2016, 26 (06) : 455 - 458
  • [2] Analytical models for predicting mechanical properties of mesh-type self-expandable metal stents with cover membrane
    Moon, Taegyun
    Hong, Daehie
    Chun, Hoon Jai
    Lee, Kyu Back
    CURRENT APPLIED PHYSICS, 2009, 9 (01) : 92 - 100
  • [3] Self-expandable metal stents are a valid option in long-term survivors of advanced esophageal cancer
    Rodrigues-Pinto, Eduardo
    Pereira, Pedro
    Baron, Todd H.
    Macedo, Guilherme
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2018, 110 (08) : 500 - 504
  • [4] Endoscopic management of complications of self-expandable metal stents for treatment of malignant esophageal stenosis and tracheoesophageal fistulas
    Bor, Renata
    Fabian, Anna
    Balint, Anita
    Farkas, Klaudia
    Szucs, Monika
    Milassin, Agnes
    Czako, Laszlo
    Rutka, Mariann
    Molnar, Tamas
    Szepes, Zoltan
    THERAPEUTIC ADVANCES IN GASTROENTEROLOGY, 2017, 10 (08): : 599 - 607
  • [5] A pilot study of fully covered self-expandable metal stents prior to neoadjuvant therapy for locally advanced esophageal cancer
    Lopes, T. L.
    Eloubeidi, M. A.
    DISEASES OF THE ESOPHAGUS, 2010, 23 (04) : 309 - 315
  • [6] Self-expandable metal stents in esophageal cancer before preoperative neoadjuvant therapy: efficacy, safety, and long-term outcomes
    Eduardo Rodrigues-Pinto
    Joel Ferreira-Silva
    Bernardo Sousa-Pinto
    Renato Medas
    Isabel Garrido
    Peter D. Siersema
    Pedro Pereira
    Guilherme Macedo
    Surgical Endoscopy, 2021, 35 : 5130 - 5139
  • [7] Self-expandable metal stents in esophageal cancer before preoperative neoadjuvant therapy: efficacy, safety, and long-term outcomes
    Rodrigues-Pinto, Eduardo
    Ferreira-Silva, Joel
    Sousa-Pinto, Bernardo
    Medas, Renato
    Garrido, Isabel
    Siersema, Peter D.
    Pereira, Pedro
    Macedo, Guilherme
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2021, 35 (09): : 5130 - 5139