Elastography by acoustic radiation force impulse technology for differentiation of benign and malignant breast lesions: a meta-analysis

被引:19
作者
Liu, BaoXian [1 ]
Zheng, YanLing [1 ]
Shan, QuanYuan [1 ]
Lu, Ying [1 ]
Lin, ManXia [1 ]
Tian, WenShuo [1 ]
Xie, XiaoYan [1 ]
机构
[1] Sun Yat Sen Univ, Inst Diagnost & Intervent Ultrasound, Affiliated Hosp 1, Div Intervent Ultrasound,Dept Med Ultrason, Guangzhou 510080, Guangdong, Peoples R China
关键词
Acoustic radiation force impulse; Virtual touch tissue imaging; Virtual touch tissue quantification; Breast cancer; Meta-analysis; SHEAR-WAVE VELOCITY; ULTRASONOGRAPHIC TISSUE QUANTIFICATION; SYSTEMATIC REVIEWS; GUIDELINES; DIAGNOSIS; ACCURACY;
D O I
10.1007/s10396-015-0658-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To perform a meta-analysis assessing the ability of elastography by acoustic radiation force impulse (ARFI) technology to differentiate benign and malignant breast lesions. PubMed, the Cochrane Library, and the Web of Knowledge before September 24, 2014 were searched. Published studies that evaluated the diagnostic performance of ARFI for characterization of focal breast lesions were included. A total of fifteen studies, including 1720 patients with 1873 breast lesions (743 cancers, 1130 benign lesions), was analyzed. Among the included studies, virtual touch tissue imaging (VTI) was used in six studies, virtual touch tissue quantification (VTQ) in eight, combined VTI and VTQ in four, and virtual touch tissue imaging quantification (VTIQ) in three. Summary sensitivity and summary specificity for distinguishing malignant from benign breast lesions were 0.913 [95 % confidence interval (CI), 0.779-0.969] and 0.871 (95 % CI 0.773-0.930) for VTI, 0.849 (95 % CI 0.805-0.884) and 0.889 (95 % CI 0.771-0.950) for VTQ, and 0.935 (95 % CI 0.892-0.961) and 0.881 (95 % CI 0.818-0.924) for combined VTI and VTQ, respectively. The area under summary receiver operating characteristic (sROC) curve of VTI, VTQ, and combined VTI and VTQ were 0.95, 0.88, and 0.96, respectively. Significant publication bias was found only in the VTQ assessment (p = 0.025). The obtained sensitivity of VTIQ ranged from 80.4 to 90.3 %, while the specificity ranged from 73.0 to 93.0 %. The summary diagnostic value of VTIQ could not be evaluated due to insufficient data. Elastography by ARFI technology could be used as a good identification tool for differentiating benign and malignant breast lesions.
引用
收藏
页码:47 / 55
页数:9
相关论文
共 30 条
[1]  
[Anonymous], CHINESE GERMAN J CLI
[2]   Virtual Touch Tissue Quantification Using Acoustic Radiation Force Impulse Technology Initial Clinical Experience With Solid Breast Masses [J].
Bai, Min ;
Du, Lianfang ;
Gu, Jiying ;
Li, Fan ;
Jia, Xiao .
JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (02) :289-294
[3]   Does blinding of readers affect the results of meta-analyses? [J].
Berlin, JA .
LANCET, 1997, 350 (9072) :185-186
[4]   Breast Mass Evaluation: Factors Influencing the Quality of US Elastography [J].
Chang, Jung Min ;
Moon, Woo Kyung ;
Cho, Nariya ;
Kim, Seung Ja .
RADIOLOGY, 2011, 259 (01) :59-64
[5]   The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed [J].
Deeks, JJ ;
Macaskill, P ;
Irwig, L .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2005, 58 (09) :882-893
[6]   A methodological review of how heterogeneity has been examined in systematic reviews of diagnostic test accuracy [J].
Dinnes, J ;
Deeks, J ;
Kirby, J ;
Roderick, P .
HEALTH TECHNOLOGY ASSESSMENT, 2005, 9 (12) :1-+
[7]   Evaluation of Virtual Touch Tissue Imaging Quantification, a New Shear Wave Velocity Imaging Method, for Breast Lesion Assessment by Ultrasound [J].
Golatta, Michael ;
Schweitzer-Martin, Mirjam ;
Harcos, Aba ;
Schott, Sarah ;
Gomez, Christina ;
Stieber, Anne ;
Rauch, Geraldine ;
Domschke, Christoph ;
Rom, Joachim ;
Schuetz, Florian ;
Sohn, Christof ;
Heil, Joerg .
BIOMED RESEARCH INTERNATIONAL, 2014, 2014
[8]   Real-time elastography for the differentiation of benign and malignant breast lesions: a meta-analysis [J].
Gong, Xia ;
Xu, Qiuhua ;
Xu, Zhengliang ;
Xiong, Ping ;
Yan, Weili ;
Chen, Yazhu .
BREAST CANCER RESEARCH AND TREATMENT, 2011, 130 (01) :11-18
[9]   Accuracy of classification of breast ultrasound findings based on criteria used for BI-RADS [J].
Heinig, J. ;
Witteler, R. ;
Schmitz, R. ;
Kiesel, L. ;
Steinhard, J. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 32 (04) :573-578
[10]   Added value of Virtual Touch IQ shear wave elastography in the ultrasound assessment of breast lesions [J].
Ianculescu, Victor ;
Ciolovan, Laura Maria ;
Dunant, Ariane ;
Vielh, Philippe ;
Mazouni, Chafika ;
Delaloge, Suzette ;
Dromain, Clarisse ;
Blidaru, Alexandru ;
Balleyguier, Corinne .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (05) :773-777