Influence of loading rate on patellar tendon mechanical properties in vivo

被引:47
作者
Koesters, A. [1 ]
Wiesinger, H. P. [1 ]
Bojsen-Moller, J. [2 ]
Mueller, E. [1 ]
Seynnes, O. R. [2 ]
机构
[1] Dept Sport Sci & Kinesiol Salzburg, Salzburg, Austria
[2] Norwegian Sch Sport Sci Oslo, Oslo, Norway
关键词
Ultrasonography; Viscoelasticity; In vivo testing; STRAIN-RATE; VISCOELASTIC PROPERTIES; STRESS-RELAXATION; STIFFNESS; RESISTANCE; LIGAMENTS; COLLAGEN; MATRIX; KNEE; CONTRACTIONS;
D O I
10.1016/j.clinbiomech.2013.12.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Rate-dependent properties of tendons have consistently been observed in vitro but in vivo studies comparing the effects of loading duration on this feature remain conflicting. The main purpose of the present study was to evaluate whether tendon loading rate per se would affect in vivo tendon mechanical properties. Methods: Twenty-two physically active male subjects were recruited. Patellar tendon deformation was recorded with ultrasonography under voluntary isometric contractions at rates of 50, 80 and 110 Nm/s, controlled via visual feedback. Findings: Subjects were able to accurately generate all three loading rates (Accuracy=2% to 15%), with a greater steadiness at 50 (CV=12.4%)and 110 Nm/s (CV=13.1%) than at 80 Nm/s (CV=22.9%). Loading rate did not appreciably affect strain or stress. However, stiffness (p(2)=0.555) and Youngs's Modulus (p(2)=0.670) were significantly higher at 80 Nm/s (21.4% and 21.6%, respectively) and at 110 Nm/s (32.5% and 32.0%, respectively) than at 50 Nm/s. Similarly, stiffness and Young's modulus were 9.9% and 8.8% higher, respectively, at 110 Nm/s than at 80 Nm/s. Interpretation: These results indicate that in vivo measurements of patellar tendon mechanics are influenced by loading rate. Moreover, they bear important methodological implications for in vivo assessment of mechanical properties of this tendon and possibly other human tendons. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:323 / 329
页数:7
相关论文
共 55 条
[1]  
[Anonymous], ADV THEOR APPL MECH
[2]   THE EFFECTS OF DONOR AGE AND STRAIN-RATE ON THE BIOMECHANICAL PROPERTIES OF BONE-PATELLAR TENDON-BONE ALLOGRAFTS [J].
BLEVINS, FT ;
HECKER, AT ;
BIGLER, GT ;
BOLAND, AL ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (03) :328-333
[3]   Muscle performance during maximal isometric and dynamic contractions is influenced by the stiffness of the tendinous structures [J].
Bojsen-Moller, J ;
Magnusson, SP ;
Rasmussen, LR ;
Kjaer, M ;
Aagaard, P .
JOURNAL OF APPLIED PHYSIOLOGY, 2005, 99 (03) :986-994
[4]   The dynamics of collagen uncrimping and lateral contraction in tendon and the effect of ionic concentration [J].
Buckley, Mark R. ;
Sarver, Joseph J. ;
Freedman, Benjamin R. ;
Soslowsky, Louis J. .
JOURNAL OF BIOMECHANICS, 2013, 46 (13) :2242-2249
[5]  
Butler D L, 1978, Exerc Sport Sci Rev, V6, P125
[6]   Influence of aging on the in vivo properties of human patellar tendon [J].
Carroll, C. C. ;
Dickinson, J. M. ;
Haus, J. M. ;
Lee, G. A. ;
Hollon, C. J. ;
Aagaard, P. ;
Magnusson, S. P. ;
Trappe, T. A. .
JOURNAL OF APPLIED PHYSIOLOGY, 2008, 105 (06) :1907-1915
[7]   A finite dissipative theory of temporary interfibrillar bridges in the extracellular matrix of ligaments and tendons [J].
Ciarletta, P. ;
Amar, M. Ben .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2009, 6 (39) :909-924
[8]   A mechanistic study for strain rate sensitivity of rabbit patellar tendon [J].
Clemmer, John ;
Liao, Jun ;
Davis, Debbie ;
Horstemeyer, Mark F. ;
Williams, Lakiesha N. .
JOURNAL OF BIOMECHANICS, 2010, 43 (14) :2785-2791
[9]   Structure-function relationships of postnatal tendon development: A parallel to healing [J].
Connizzo, Brianne K. ;
Yannascoli, Sarah M. ;
Soslowsky, Louis J. .
MATRIX BIOLOGY, 2013, 32 (02) :106-116
[10]   Differences in tendon properties in elite badminton players with or without patellar tendinopathy [J].
Couppe, C. ;
Kongsgaard, M. ;
Aagaard, P. ;
Vinther, A. ;
Boesen, M. ;
Kjaer, M. ;
Magnusson, S. P. .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2013, 23 (02) :e89-e95