Simple dose rate measurements for a very high synchrotron X-ray flux

被引:13
|
作者
Liu, Chi-Jen [1 ]
Wang, Chang-Hai [1 ]
Wang, Cheng-Liang [1 ]
Hwu, Y. [1 ,2 ,3 ,4 ]
Lin, Chien-Yi [5 ]
Margaritondo, G. [6 ]
机构
[1] Acad Sinica, Inst Phys, Taipei 115, Taiwan
[2] Natl Tsing Hua Univ, Dept Engn & Syst Sci, Hsinchu 300, Taiwan
[3] Natl Synchrotron Radiat Res Ctr, Hsinchu 300, Taiwan
[4] Natl Taiwan Ocean Univ, Inst Optoelect Sci, Chilung 202, Taiwan
[5] Mackay Mem Hosp, Dept Radiol, Hsinchu 300, Taiwan
[6] Ecole Polytech Fed Lausanne, CH-1015 Lausanne, Switzerland
关键词
methylene blue; bleaching; dosimetry; Fricke dosimetry; intense X-rays;
D O I
10.1107/S0909049509007225
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Dose measurements based on methylene blue (MB) bleaching, widely used for ultraviolet light, can also be applied to X-rays including very high flux levels. This method has been tested by using both MB bleaching and Fricke dosimetry for a conventional monochromatic X-ray source and then for 'white-beam' synchrotron radiation. The results show that MB bleaching dosimetry can easily measure X-ray doses up to at least 10(5) Gy s(-1), as long as the MB concentration is sufficiently high. This condition can be verified from the deviations from linearity of the bleaching versus exposure time.
引用
收藏
页码:395 / 397
页数:3
相关论文
共 50 条
  • [1] Hydrogenated amorphous silicon high flux x-ray detectors for synchrotron microbeam radiation therapy
    Large, Matthew J.
    Bizzarri, Marco
    Calcagnile, Lucio
    Caprai, Mirco
    Caricato, Anna Paola
    Catalano, Roberto
    Cirrone, Giuseppe A. P.
    Croci, Tommaso
    Cuttone, Giacomo
    Dunand, Sylvain
    Fabi, Michele
    Frontini, Luca
    Gianfelici, Benedetta
    Grimani, Catia
    Ionica, Maria
    Kanxheri, Keida
    Lerch, Michael L. F.
    Liberali, Valentino
    Martino, Maurizio
    Maruccio, Giuseppe
    Mazza, Giovanni
    Menichelli, Mauro
    Monteduro, Anna Grazia
    Moscatelli, Francesco
    Morozzi, Arianna
    Pallotta, Stefania
    Papi, Andrea
    Passeri, Daniele
    Pedio, Maddalena
    Petringa, Giada
    Peverini, Francesca
    Piccolo, Lorenzo
    Placidi, Pisana
    Quarta, Gianluca
    Rizzato, Silvia
    Rossi, Alessandro
    Rossi, Giulia
    de Rover, Vincent
    Sabbatini, Federico
    Servoli, Leonello
    Stabile, Alberto
    Talamonti, Cinzia
    Tosti, Luca
    Villani, Mattia
    Wheadon, Richard J.
    Wyrsch, Nicolas
    Zema, Nicola
    Petasecca, Marco
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (13)
  • [2] Valency conversion of samarium ions under high dose synchrotron generated X-ray radiation
    Belev, George
    Okada, Go
    Tonchev, Dancho
    Koughia, Cyril
    Varoy, Chris
    Edgar, Andy
    Wysokinski, Tomasz
    Chapman, Dean
    Kasap, Safa
    PHYSICA STATUS SOLIDI C: CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 8, NO 9, 2011, 8 (09): : 2822 - 2825
  • [3] Absorbed dose determination in kilovoltage X-ray synchrotron radiation using alanine dosimeters
    D. J. Butler
    J. E. Lye
    T. E. Wright
    D. Crossley
    P. H. G. Sharpe
    A. W. Stevenson
    J. Livingstone
    J. C. Crosbie
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 943 - 950
  • [4] Absorbed dose determination in kilovoltage X-ray synchrotron radiation using alanine dosimeters
    Butler, D. J.
    Lye, J. E.
    Wright, T. E.
    Crossley, D.
    Sharpe, P. H. G.
    Stevenson, A. W.
    Livingstone, J.
    Crosbie, J. C.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (04) : 943 - 950
  • [5] Alanine response to low energy synchrotron x-ray radiation
    van den Elzen, P.
    Sander, T.
    Palmans, H.
    McManus, M.
    Woodall, N.
    Lee, N.
    Fox, O. J. L.
    Jones, R. M.
    Angal-Kalinin, D.
    Subiel, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (06)
  • [6] MOSFET dosimetry with high spatial resolution in intense synchrotron-generated x-ray microbeams
    Siegbahn, E. A.
    Braeuer-Krisch, E.
    Bravin, A.
    Nettelbeck, H.
    Lerch, M. L. F.
    Rosenfeld, A. B.
    MEDICAL PHYSICS, 2009, 36 (04) : 1128 - 1137
  • [7] A novel calorimeter for synchrotron produced monochromatic x-ray beams
    El Gamal, Islam
    Dessureault, Jean
    McEwen, Malcolm R. R.
    MEDICAL PHYSICS, 2023, 50 (10) : 6543 - 6553
  • [8] Oblique Surface Dose Calculation in High-Energy X-ray Therapy
    Narihiro, Naomasa
    Oita, Masataka
    Takeda, Yoshihiro
    ACTA MEDICA OKAYAMA, 2020, 74 (05) : 415 - 422
  • [9] Suitability of laser stimulated TLD arrays as patient dose monitors in high dose x-ray imaging
    Geise, RA
    Schueler, BA
    Lien, W
    Jones, SC
    MEDICAL PHYSICS, 1997, 24 (10) : 1643 - 1646
  • [10] Monitoring of Ultra-High Dose Rate Pulsed X-ray Facilities with Radioluminescent Nitrogen-Doped Optical Fiber
    Vidalot, Jeoffray
    Campanella, Cosimo
    Dachicourt, Julien
    Marcandella, Claude
    Duhamel, Olivier
    Morana, Adriana
    Poujols, David
    Assaillit, Gilles
    Gaillardin, Marc
    Boukenter, Aziz
    Ouerdane, Youcef
    Girard, Sylvain
    Paillet, Philippe
    SENSORS, 2022, 22 (09)