An explorative investigation of functional differences in plantar center of pressure of four foot types using sample entropy method

被引:19
作者
Mei, Zhanyong [1 ]
Ivanov, Kamen [2 ,3 ]
Zhao, Guoru [2 ]
Li, Huihui [2 ]
Wang, Lei [2 ]
机构
[1] Chengdu Univ Technol, Coll Informat Sci & Technol, Chengdu, Peoples R China
[2] Shenzhen Inst Adv Technol, Shenzhen Key Lab Low Cost Healthcare, 1068 Xueyuan Ave, Shenzhen 518055, Peoples R China
[3] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
关键词
Gait; Foot type; Plantar pressure; Biomechanics; ARCH STRUCTURE; POSTURAL SWAY; WALKING SPEED; FLAT FOOT; PREVALENCE; REGULARITY; PAIN; GAIT; CHILDREN;
D O I
10.1007/s11517-016-1532-7
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In the study of biomechanics of different foot types, temporal or spatial parameters derived from plantar pressure are often used. However, there is no comparative study of complexity and regularity of the center of pressure (CoP) during the stance phase among pes valgus, pes cavus, hallux valgus and normal foot. We aim to analyze whether CoP sample entropy characteristics differ among these four foot types. In our experiment participated 40 subjects with normal feet, 40 with pes cavus, 19 with pes valgus and 36 with hallux valgus. A Footscan (R) system was used to collect CoP data. We used sample entropy to quantify several parameters of the investigated four foot types. These are the displacement in medial-lateral (M/L) and anterior-posterior (A/P) directions, as well as the vertical ground reaction force of CoP during the stance phase. To fully examine the potential of the sample entropy method for quantification of CoP components, we provide results for two cases: calculating the sample entropy of normalized CoP components, as well as calculating it using the raw data of CoP components. We also explored what are the optimal values of parameters m (the matching length) and r (the tolerance range) when calculating the sample entropy of CoP data obtained during the stance phases. According to statistical results, some factors significantly influenced the sample entropy of CoP components. The sample entropies of non-normalized A/P values for the left foot, as well as for the right foot, were different between the normal foot and pes valgus, and between the normal foot and hallux valgus. The sample entropy of normalized M/L displacement of the right foot was different between the normal foot and pes cavus. The measured variable for A/P and M/L displacements could serve for the study of foot function.
引用
收藏
页码:537 / 548
页数:12
相关论文
共 47 条
[1]   A novel application of sample entropy to the electrocardiogram of atrial fibrillation [J].
Alcaraz, R. ;
Rieta, J. J. .
NONLINEAR ANALYSIS-REAL WORLD APPLICATIONS, 2010, 11 (02) :1026-1035
[2]  
[Anonymous], J FOOT ANKLE RES
[3]   Flat foot functional evaluation using pattern recognition of ground reaction data [J].
Bertani, A ;
Cappello, A ;
Benedetti, MG ;
Simoncini, L ;
Catani, F .
CLINICAL BIOMECHANICS, 1999, 14 (07) :484-493
[4]   The effect of pes caves on foot pain and plantar pressure [J].
Burns, J ;
Crosbie, J ;
Hunt, A ;
Ouvrier, R .
CLINICAL BIOMECHANICS, 2005, 20 (09) :877-882
[5]   High prevalence of foot diseases in Europe: results of the Achilles Project [J].
Burzykowski, T ;
Molenberghs, G ;
Abeck, D ;
Haneke, E ;
Hay, R ;
Katsambas, A ;
Roseeuw, D ;
van de Kerkhof, P ;
van Aelst, R ;
Marynissen, G .
MYCOSES, 2003, 46 (11-12) :496-505
[6]   Flatfoot Prevalence and Foot Dimensions of 5-to 13-Year-Old Children in Taiwan [J].
Chen, Jiann-Perng ;
Chung, Meng-Jung ;
Wang, Mao-Jiun .
FOOT & ANKLE INTERNATIONAL, 2009, 30 (04) :326-332
[7]   Gender and walking speed effects on plantar pressure distribution for adults aged 20-60 years [J].
Chung, Meng-Jung ;
Wang, Mao-Jiun .
ERGONOMICS, 2012, 55 (02) :194-200
[8]   The trajectory of the centre of pressure during barefoot running as a potential measure for foot function [J].
De Cock, A. ;
Vanrenterghem, J. ;
Willems, T. ;
Witvrouw, E. ;
De Clercq, D. .
GAIT & POSTURE, 2008, 27 (04) :669-675
[9]   Children with cerebral palsy exhibit greater and more regular postural sway than typically developing children [J].
Donker, Stella F. ;
Ledebt, Annick ;
Roerdink, Melvyn ;
Savelsbergh, Geert J. P. ;
Beek, Peter J. .
EXPERIMENTAL BRAIN RESEARCH, 2008, 184 (03) :363-370
[10]   Plantar pressure reduction in step-to gait: A biomechanical investigation and clinical feasibility study [J].
Drerup, B. ;
Szczepaniak, A. ;
Wetz, H. H. .
CLINICAL BIOMECHANICS, 2008, 23 (08) :1073-1079