A miniaturized spray-assisted fine-droplet-formation-based liquid-phase microextraction method for the simultaneous determination of fenpiclonil, nitrofen and fenoxaprop-ethyl as pesticides in soil samples

被引:5
作者
Turan, Nouha Bakaraki [1 ]
Bakirdere, Sezgin [2 ,3 ]
机构
[1] Yildiz Tech Univ, Fac Civil Engn, Environm Engn Dept, TR-34220 Istanbul, Turkey
[2] Yildiz Tech Univ, Fac Art & Sci, Chem Dept, TR-34220 Istanbul, Turkey
[3] Turkish Acad Sci TUBA, Piyade Sokak 27, TR-06690 Ankara, Turkey
关键词
CHROMATOGRAPHY-MASS SPECTROMETRY; GC-MS; EXTRACTION; WATER; RESIDUES; FUNGICIDES; SOLVENT;
D O I
10.1002/rcm.8943
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale Pesticides are a group of micropollutants that persist for a long time in the environment and pose threats to life. Much effort has been devoted to developing pre-concentration methods capable of producing samples suitable for the detection of pesticides. However, better methods are still required to detect these compounds when they are present in trace concentrations in soils. Method Spray-assisted fine-droplet-formation-based liquid-phase microextraction was used to prepare soil samples containing three different pesticides, fenpiclonil, nitrofen and fenoxaprop-ethyl, for subsequent analysis by gas chromatography/mass spectrometry (GC/MS). A spraying apparatus was used for the dispersion of the extraction solvent into the sample/standard solution to improve the extraction efficiency. Optimization studies were performed to lower the detection limits of these analytes and the results obtained by the application of the newly developed system were compared with those obtained using the conventional GC/MS method. Results A calibration curve over the range 5.0-100 mu g L-1 was obtained under the optimal conditions. The limits of detection and quantification were 1.56-1.80 mu g L-1 and 5.21-5.98 mu g L-1, respectively. The enhancements in detection ability over the conventional method for the three tested pesticides were 188.01, 176.96 and 517.14 for fenpiclonil, nitrofen and fenoxaprop-ethyl, respectively Recovery studies performed in soil samples were satisfactory reflecting accurate applicability of the developed method. Conclusions The developed microextraction method is a time-saving and simple version of the traditional dispersive liquid-liquid microextraction method that also reduces the use of dispersive solvents.
引用
收藏
页数:6
相关论文
共 33 条
[1]   Recent advances in dispersive liquid-liquid microextraction for pesticide analysis [J].
Ahmad, W. ;
Al-Sibaai, A. A. ;
Bashammakh, A. S. ;
Alwael, H. ;
El-Shahawi, M. S. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2015, 72 :181-192
[2]   Concentration and distribution of pesticide residues in soil: Non-dietary human health risk assessment [J].
Bhandari, Govinda ;
Atreya, Kishor ;
Scheepers, Paul T. J. ;
Geissen, Violette .
CHEMOSPHERE, 2020, 253
[3]   Pesticides, environment, and food safety [J].
Carvalho, Fernando P. .
FOOD AND ENERGY SECURITY, 2017, 6 (02) :48-60
[4]   HPLC DETERMINATION OF FENOXAPROP AND FENOXAPROP-ETHYL IN DIFFERENT SOILS [J].
CELI, L ;
NEGRE, M ;
GENNARI, M .
PESTICIDE SCIENCE, 1993, 38 (01) :43-47
[5]   A novel and rapid extraction protocol for sensitive and accurate determination of prochloraz in orange juice samples: Vortex-assisted spraying-based fine droplet formation liquid-phase microextraction before gas chromatography-mass spectrometry [J].
Dikmen, Yaren ;
Guleryuz, Aybuke ;
Metin, Berfin ;
Bodur, Suleyman ;
Oner, Miray ;
Bakirdere, Sezgin .
JOURNAL OF MASS SPECTROMETRY, 2020, 55 (10)
[6]  
Ersoy N., 2016, ASIAN J CHEM, V28, P1011, DOI [10.14233/ajchem.2016.19564, DOI 10.14233/AJCHEM.2016.19564]
[7]   Versatile magnetic carbon nanotubes for sampling and pre concentration of pesticides in environmental water [J].
Fernandes Barbosa, Frederico Hayala ;
Menezes, Helvecio Costa ;
de Carvalho Teixeira, Ana Paula ;
Serp, Philippe ;
Antipoff, Vitor ;
Cardeal, Zenilda de Lourdes .
TALANTA, 2017, 167 :538-543
[8]   Effect of sample volume on quantitative analysis by solid-phase microextraction .1. Theoretical considerations [J].
Gorecki, T ;
Pawliszyn, J .
ANALYST, 1997, 122 (10) :1079-1086
[9]   DLLME Combined with GC-MS for the Determination of Methylparaben, Ethylparaben, Propylparaben and Butylparaben in Beverage Samples [J].
Han, Yi ;
Jia, Xiaoyu ;
Liu, Xinli ;
Duan, Taicheng ;
Chen, Hangting .
CHROMATOGRAPHIA, 2010, 72 (3-4) :351-355
[10]   Optimization and application of ultrasonic extraction and Soxhlet extraction followed by solid phase extraction for the determination of triazine pesticides in soil and sediment [J].
Kunene, P. N. ;
Mahlambi, P. N. .
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2020, 8 (02)