Prediction of the in-plane mid-span displacement of cold-formed steel floor with steel form-deck and gypsum-based self-leveling underlayment

被引:10
作者
Guan, Yu [1 ]
Zhou, Xuhong [1 ,2 ,3 ]
Shi, Yu [2 ,3 ]
Yao, Xinmei [1 ]
机构
[1] Changan Univ, Sch Civil Engn, Xian 710061, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[3] Chongqing Univ, Minist Educ, Key Lab New Technol Construct Cities Mt Area, Chongqing 400045, Peoples R China
基金
中国国家自然科学基金;
关键词
Cold-formed steel; Floor system; In-plane displacement; Experimental investigation; Theoretical method; STIFFNESS;
D O I
10.1016/j.jcsr.2019.03.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cold-formed steel composite floor systems have been widely used in cold-formed steel framing for mid-rise building construction, primarily owing to its structural and economic efficiency. The composite floors consist of cold-formed steel C-shape joists and subfloor with cold-formed steel form-deck and gypsum-based self-leveling underlayment. This paper presents a theoretical method, an experimental investigation, and a simplified model analysis on the in-plane displacement of cold-formed steel composite floors under horizontal loads. Based on the design method of timber floors, the calculation methodology of the mid-span in-plane displacement of cold-formed steel floor with steel form-deck and gypsum-based self-leveling underlayment is proposed. Subsequently, cyclic shear tests of two full-scale floors with and without gypsum-based self-leveling underlayment were executed to investigate the failure mode, load bearing capacity, and in-plane displacement. The test results indicated that the primary failure mode of the specimens was the shear failure of self-drilling screws that connected the steel form-deck and end joists. Furthermore, the in-plane displacement of the test results agreed well with that of the proposed method. Finally, referring to the deformation results of floors under different loading stages, the composite floor analysis model was simplified to a nonlinear diagonal spring model according to the method of equivalent in-plane stiffness, and it was verified through ABAQUS finite element analysis. This study provides a useful design basis for the design and application of cold-formed steel composite floors. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:124 / 135
页数:12
相关论文
共 25 条
[1]  
[ABAQUS Inc. Finite Element Analysis], 2013, AB 6 13 COMP AID ENG
[2]  
AISI (American Iron and Steel Institute), 2012, S23007 AISI
[3]  
AISI (American Iron and Steel Institute), 2013, Test standard for cantilever test method for cold-formed steel diaphragms
[4]  
[Anonymous], 2006, Assessment and Improvement of the Structural Performance of Buildings in Earthquakes
[5]  
AWC, 2015, ANSI AWC SDPWS 2015
[6]   In-Plane Stiffness of Traditional Timber Floors Strengthened with CLT [J].
Branco, Jorge M. ;
Kekeliak, Milos ;
Lourenco, Paulo B. .
MATERIALS AND JOINTS IN TIMBER STRUCTURES: RECENT DEVELOPMENTS OF TECHNOLOGY, 2014, 9 :725-737
[7]  
Chatterjee A., 2016, Structural system reliability with application to light steel-framed buildings
[8]   System Reliability of Floor Diaphragms Framed from Cold-Formed Steel with Wood Sheathing [J].
Chatterjee, Aritra ;
Arwade, Sanjay R. ;
Schafer, Benjamin W. ;
Moen, Cristopher D. .
JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (02)
[9]  
Florig S., 2016, FULL SCALE TESTS COL
[10]  
Guan Y., 2016, STUDY IN PLANE MECH