Repeat transcatheter aortic valve implantation using a latest generation balloon-expandable device for treatment of failing transcatheter heart valves

被引:10
作者
Schaefer, Andreas [1 ]
Treede, Hendrik [1 ]
Seiffert, Moritz [2 ]
Deuschl, Florian [2 ]
Schofer, Niklas [2 ]
Schneeberger, Yvonne [1 ]
Blankenberg, Stefan [2 ]
Reichenspurner, Hermann [1 ]
Schaefer, Ulrich [2 ]
Conradi, Lenard [1 ]
机构
[1] Univ Heart Ctr Hamburg, Dept Cardiovasc Surg, D-20246 Hamburg, Germany
[2] Univ Heart Ctr Hamburg, Dept Gen & Intervent Cardiol, D-20246 Hamburg, Germany
关键词
Aortic valve disease; Aortic valve stenosis; Paravalvular leak; Percutaneous valve therapy; Structural heart disease intervention; TAVI; THV; REGURGITATION; REPLACEMENT; PROSTHESIS; ANNULUS; IMPACT;
D O I
10.1186/s13019-016-0398-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Paravalvular leakage (PVL) is a known complication of transcatheter aortic valve implantation (TAVI) and is associated with poor outcome. Besides balloon-post-dilatation, valve-in-valve (ViV) procedures can be taken into consideration to control this complication. Herein we present initial experience with use of the latest generation balloon-expandable Edwards Sapien 3 (R) (S3) transcatheter heart valve (THV) for treatment of failing THVs. Methods: Between 01/2014 and 12/2014 three patients (two male, age: 71-80 y, log EUROScore I: 11.89 - 32.63) with failing THVs were refered to our institution for further treatment. THV approach with secondary implantation of an S3 was chosen after mutual agreement of the local interdisciplinary heart team at an interval of 533-1119 days from the index procedure. The performed procedures consisted of: S3 in Sapien XT, JenaValve and CoreValve. Results: Successful transfemoral implantation with significant reduction of PVL was achieved in all cases. No intraprocedural complications occured regarding placement of the S3 with a postprocedural effective orifice area (EOA) of 1.5-2.5 cm(2) and pressure gradients of max/mean 14/6-36/16 mmHg. 30-day mortality was 0 %. At the latest follow-up of 90-530 days, all patients are alive and well with satisfactory THV function. Regarding VARC-2 criteria one major bleeding and one TIA was reported. Conclusions: In the instance of moderate or severe aortic regurgitation after TAVI, S3 ViV deployment is an excellent option to reduce residual regurgitation to none or mild. For further assertions concerning functional outcomes long-term results have to be awaited.
引用
收藏
页数:6
相关论文
共 17 条
[1]   Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[2]   Computed tomography-based evaluation of aortic annulus, prosthesis size and impact on early residual aortic regurgitation after transcatheter aortic valve implantation [J].
Buzzatti, Nicola ;
Maisano, Francesco ;
Latib, Azeem ;
Cioni, Micaela ;
Taramasso, Maurizio ;
Mussardo, Marco ;
Colombo, Antonio ;
Alfieri, Ottavio .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (01) :43-51
[3]   Edwards Sapien XT valve placement as treatment option for aortic regurgitation after transfemoral CoreValve implantation: a multicenter experience [J].
Diemert, Patrick ;
Lange, Philipp ;
Greif, Martin ;
Seiffert, Moritz ;
Conradi, Lenard ;
Massberg, Steffen ;
Blankenberg, Stefan ;
Reichenspurner, Hermann ;
Hagl, Christian ;
Schmitz, Christoph ;
Schroefel, Holger ;
Treede, Hendrik ;
Schymik, Gerhard ;
Kupatt, Christian .
CLINICAL RESEARCH IN CARDIOLOGY, 2014, 103 (03) :183-190
[4]   Interventional options for severe aortic regurgitation after transcatheter aortic valve implantation: balloons, snares, valve-in-valve [J].
Eggebrecht, Holger ;
Doss, Mirko ;
Schmermund, Axel ;
Nowak, Bernd ;
Krissel, Josef ;
Voigtlaender, Thomas .
CLINICAL RESEARCH IN CARDIOLOGY, 2012, 101 (06) :503-507
[5]   Noncontrast 3D CMR Imaging for Aortic Valve Annulus Sizing in TAVR [J].
Gopal, Ambarish ;
Grayburn, Paul A. ;
Mack, Molly ;
Chacon, Isabel ;
Kim, Rebeca ;
Montenegro, Debbie ;
Phan, Teresa ;
Rudolph, Jill ;
Filardo, Giovanni ;
Mack, Michael J. ;
Gopalakrishnan, Deepika .
JACC-CARDIOVASCULAR IMAGING, 2015, 8 (03) :375-378
[6]   Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation [J].
Gripari, Paola ;
Ewe, See Hooi ;
Fusini, Laura ;
Muratori, Manuela ;
Ng, Arnold C. T. ;
Cefalu, Claudia ;
Delgado, Victoria ;
Schalij, Martin J. ;
Bax, Jeroen J. ;
Marsan, Nina Ajmone ;
Tamborini, Gloria ;
Pepi, Mauro .
HEART, 2012, 98 (16) :1229-1236
[7]   TRINITY heart valve prosthesis: a novel repositionable and retrievable transapical transcatheter aortic valve system [J].
Hengstenberg, Christian ;
Condado, Jose ;
Garcia, David ;
Marin Martinez, Milka ;
La Forgia, Giambattista ;
Ebner, Adrian ;
Gallo, Santiago ;
Silva, Enrique ;
Holzamer, Andreas ;
Husser, Oliver ;
Hilker, Michael .
EUROINTERVENTION, 2015, 10 (11) :1332-1335
[8]   Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement [J].
Kodali, Susheel K. ;
Williams, Mathew R. ;
Smith, Craig R. ;
Svensson, Lars G. ;
Webb, John G. ;
Makkar, Raj R. ;
Fontana, Gregory P. ;
Dewey, Todd M. ;
Thourani, Vinod H. ;
Pichard, Augusto D. ;
Fischbein, Michael ;
Szeto, Wilson Y. ;
Lim, Scott ;
Greason, Kevin L. ;
Teirstein, Paul S. ;
Malaisrie, S. Chris ;
Douglas, Pamela S. ;
Hahn, Rebecca T. ;
Whisenant, Brian ;
Zajarias, Alan ;
Wang, Duolao ;
Akin, Jodi J. ;
Anderson, William N. ;
Leon, Martin B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (18) :1686-1695
[9]   Transcatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis [J].
Makkar, Raj R. ;
Fontana, Gregory P. ;
Jilaihawi, Hasan ;
Kapadia, Samir ;
Pichard, Augusto D. ;
Douglas, Pamela S. ;
Thourani, Vinod H. ;
Babaliaros, Vasilis C. ;
Webb, John G. ;
Herrmann, Howard C. ;
Bavaria, Joseph E. ;
Kodali, Susheel ;
Brown, David L. ;
Bowers, Bruce ;
Dewey, Todd M. ;
Svensson, Lars G. ;
Tuzcu, Murat ;
Moses, Jeffrey W. ;
Williams, Matthew R. ;
Siegel, Robert J. ;
Akin, Jodi J. ;
Anderson, William N. ;
Pocock, Stuart ;
Smith, Craig R. ;
Leon, Martin B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (18) :1696-1704
[10]   Use of a balloon-expandable transfemoral sheath in a TAVI cohort with complex access site - a propensity score matched analysis [J].
Sedaghat, Alexander ;
von Dobbeler, Conrad ;
Sontag, Bruno ;
Sinning, Jan-Malte ;
Fimmers, Rolf ;
Mellert, Fritz ;
Schiller, Wolfgang ;
Welz, Armin ;
Grube, Eberhard ;
Nickenig, Georg ;
Hauptmann, Karl Eugen ;
Werner, Nikos .
EUROINTERVENTION, 2015, 11 (06) :698-704