PERFORMANCE OF A MULTI-GROUNDED DISTRIBUTION NETWORK WITH A FOUR-WIRE THREE-PHASE POWER CONDITIONER

被引:0
|
作者
Duarte, Samuel N. [1 ]
Souza, Bruno C. [1 ]
Almeida, Pedro M. [1 ]
Araujo, Leandro R. [1 ]
Barbosa, Pedro G. [1 ]
机构
[1] Univ Fed Juiz de Fora, Grad Program Elect Engn, Juiz De Fora, MG, Brazil
来源
2019 IEEE 15TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 5TH IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC) | 2019年
关键词
Distribution Network; Power Conditioner; Voltage Unbalance; DISTRIBUTION-SYSTEMS; VOLTAGE; FLOW;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a simplified analysis of a multi-grounded distribution network compensated by a four-wire three-phase power conditioner. The effect of the neutral conductors and grounding resistances on the voltage unbalance factor are demonstrated, in steady-state, performing digital simulations using the OpenDSS package. Then, a power conditioner is connected to the distribution network to compensate for the currents drained by an unbalanced load. The control loops used to control the AC currents and the DC voltage of the power conditioner are also presented. Results of time-domain simulations show that, although the unbalance can not be fully mitigated, the power conditioner can reduce the voltage unbalance and neutral voltages of the distribution network.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Analysis of high neutral current in three-phase four-wire multi-grounded distribution feeders
    Chang, GW
    Chiu, MJ
    Lee, KS
    Hsu, YF
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 531 - 535
  • [2] Three-phase four-wire power flow solution for multi-grounded distribution networks with non-bolted grounding
    Yang, Nien-Che
    Zeng, Song-Ting
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2024, 18 (23) : 3914 - 3927
  • [3] Three-phase power flow solution for multi-grounded four-wire residential networks considering neutral grounding
    Yang, Nien-Che
    Zeng, Song-Ting
    ENERGY AND BUILDINGS, 2024, 323
  • [4] Analysis of multi-grounded four-wire distribution systems considering the neutral grounding
    Chen, TH
    Yang, WC
    IEEE TRANSACTIONS ON POWER DELIVERY, 2001, 16 (04) : 710 - 717
  • [5] Analysis of multi-grounded four-wire distribution systems considering the neutral grounding
    Chen, TH
    Yang, WC
    PICA 2001: 22ND IEEE POWER ENGINEERING SOCIETY INTERNATIONAL CONFERENCE ON POWER INDUSTRY COMPUTER APPLICATIONS, 2001, : 393 - 397
  • [6] Power Active Filter Installation Effect in Three-Phase Four-Wire Distribution Network
    Zemerov, G. G.
    Ilyina, N. A.
    Ilyina, O. V.
    Sokol, E. I.
    Tugay, D. V.
    EDM: 2009 10TH INTERNATIONAL CONFERENCE AND SEMINAR ON MICRO/NANOTECHNOLOGIES AND ELECTRON DEVICES, 2009, : 395 - +
  • [7] A Simplified Control Algorithm for Three-Phase, Four-Wire Unified Power Quality Conditioner
    Singh, Bhim
    Venkateswarlu, P.
    JOURNAL OF POWER ELECTRONICS, 2010, 10 (01) : 91 - 96
  • [8] A 100kVA power conditioner for three-phase four-wire emergency generators
    Jeong, CY
    Cho, JG
    Kang, Y
    Rim, GH
    Song, EH
    PESC 98 RECORD - 29TH ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1 AND 2, 1998, : 1906 - 1911
  • [9] Output feedback control of a three-phase four-wire unified power quality conditioner
    Benazza, Bouchaib
    Ouadi, Hamid
    Giri, Fouad
    ASIAN JOURNAL OF CONTROL, 2020, 22 (03) : 1147 - 1162
  • [10] A Three-Phase Four-Wire Unified Power Quality Conditioner Without Series Transformers
    Monteiro, L. F. C.
    Pinto, J. G.
    Afonso, J. L.
    Bellar, M. D.