Sensor for headspace pressure and H2O concentration measurements in closed vials by tunable diode laser absorption spectroscopy

被引:24
作者
Cai, Tingdong [1 ,2 ]
Wang, Guishi [1 ]
Cao, Zhensong [1 ]
Zhang, Weijun [1 ]
Gao, Xiaoming [1 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Atmospher Composit & Opt Radiat, Hefei 230031, Peoples R China
[2] Jiangsu Normal Univ, Coll Phys & Elect Engn, Xuzhou 221116, Peoples R China
基金
中国国家自然科学基金;
关键词
Tunable diode laser absorption spectroscopy (TDLAS); Sensor; Headspace analysis; Pressure and H2O concentration; PRODUCT TEMPERATURE; LYOPHILIZATION; MOISTURE; POINT;
D O I
10.1016/j.optlaseng.2013.12.005
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The concentration of H2O and the pressure in the headspace of vials are simultaneously measured by a tunable diode laser sensor based on absorption spectroscopy techniques. The 7168.437 cm(-1) spectral line of H2O is chosen as the sensing transition for its strong absorption strength and being reasonably far away from its neighboring molecular transitions. In order to prevent interference absorption by ambient water vapor in the room air, a difference between the measured signal and the referenced signal is used to calculate the pressure and H2O concentration in the headspace of vials, eliminating the need for inert gas purges and calibration with known gas. The validation of the sensor is conducted in a static vial, yielding an accuracy of 1.23% for pressure and 3.81% for H2O concentration. The sensitivity of the sensor is estimated to be about 2.5 Torr for pressure and 400 ppm for H2O concentration over a 3 cm absorption path length respectively. Accurate measurements for commercial freeze-dried products demonstrate the in-line applications of the sensor for the pharmaceutical industry. (C) 2014 Published by Elsevier Ltd.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 34 条
  • [1] Diode laser absorption sensors for gas-dynamic and combustion flows
    Allen, MG
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (04) : 545 - 562
  • [2] BARDAT A, 1993, J PARENT SCI TECHN, V47, P293
  • [3] MEASUREMENT OF WATER-VAPOR PRESSURE AND ACTIVITY USING INFRARED DIODE-LASER ABSORPTION-SPECTROSCOPY
    BONE, SA
    CUMMINS, PG
    DAVIES, PB
    JOHNSON, SA
    [J]. APPLIED SPECTROSCOPY, 1993, 47 (06) : 834 - 843
  • [4] CAMERON P, 1997, GOOD PHARM FREEZE DR
  • [5] Cavatur R K, 1998, Pharm Dev Technol, V3, P579, DOI 10.3109/10837459809028642
  • [6] CONNELLY JP, 1993, J PARENT SCI TECHN, V47, P70
  • [7] Cook Isobel A, 2011, PDA J Pharm Sci Technol, V65, P457, DOI 10.5731/pdajpst.2011.00760
  • [8] Corsi C, 1999, EUR PHYS J D, V6, P327, DOI 10.1007/s100530050316
  • [9] David B., 2012, INT J BIOL PHARM RES, V32, P82
  • [10] Demtroder W., 2003, LASER SPECTROSCOPY