biomechanics; finite element analysis; posterior motion preserving implants; spine arthroplasty; facet joint forces; spine mechanics; dynamic fixator; validation; FACET JOINT OSTEOARTHRITIS; FINITE-ELEMENT MODEL; LUMBAR SPINE; INTRADISCAL PRESSURE; DISC DEGENERATION; INTERVERTEBRAL DISC; STEPWISE REDUCTION; CALIBRATION METHOD; MOTION; ADJACENT;
D O I
10.1097/BRS.0b013e3181920e9c
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Finite element and in vitro study. Objective. Finite element calculations to delineate a dynamic fixator and confirmation with an in vitro experiment. Summary and Background Data. In the last few years, there was a paradigm shift from rigid to dynamic fixation of spinal segments. However, some so-called dynamic implants like the Dynesys performed still stiffer than anticipated. The aim of this study was to optimize a dynamic stabilization system. Methods. The development steps of this implant design can be summarized in a development loop. First, a finite element model of an intact human L4-L5 segment was used to delineate implant stiffness parameters for the implant, in consideration of clinical concerns and safety aspects. These data were used in a second step, leading to the final implant design. This development process was completed with an appropriate in vitro experiment. The optimal axial and bending stiffness were computed to reduce the spinal motion by 30%. For the validation process, in vitro tests were performed on 6 human lumbar spinal segments L2-L3 with a median age of 52. The model and the specimens were loaded with pure unconstrained moments of 7.5 Nm in flexion, extension, lateral bending, and axial rotation. Results. This study demonstrated the advantages of employing a finite element model for the implant parameter delineation. It was possible to prospectively outline the needed stiffness parameters for a desired spinal range of motion achievement. Conclusion. In summary, FEM may accelerate the development and the realization of a new implant design.
引用
收藏
页码:255 / 261
页数:7
相关论文
共 22 条
[11]   APPLICATION OF A STEREORADIOGRAPHIC METHOD FOR THE STUDY OF INTERVERTEBRAL MOTION [J].
PLAMONDON, A ;
GAGNON, M ;
MAURAIS, G .
SPINE, 1988, 13 (09) :1027-1032
[12]   Lumbar motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions [J].
Schlegel, JD ;
Smith, JA ;
Schleusener, RL .
SPINE, 1996, 21 (08) :970-981
[13]   Application of a new calibration method for a three-dimensional finite element model of a human lumbar annulus fibrosus [J].
Schmidt, H ;
Heuer, F ;
Simon, U ;
Kettler, A ;
Rohlmann, A ;
Claes, L ;
Wilke, HJ .
CLINICAL BIOMECHANICS, 2006, 21 (04) :337-344
[14]   The relation between the instantaneous center of rotation and facet joint forces - A finite element analysis [J].
Schmidt, Hendrik ;
Heuer, Frank ;
Claes, Lutz ;
Wilke, Hans-Joachim .
CLINICAL BIOMECHANICS, 2008, 23 (03) :270-278
[15]   Application of a calibration method provides more realistic results for a finite element model of a lumbar spinal segment [J].
Schmidt, Hendrik ;
Heuer, Frank ;
Drumm, Joerg ;
Klezl, Zdenek ;
Claes, Lutz ;
Wilke, Hans-Joachim .
CLINICAL BIOMECHANICS, 2007, 22 (04) :377-384
[16]   Intradiscal pressure, shear strain, and fiber strain in the intervertebral disc under combined loading [J].
Schmidt, Hendrik ;
Kettler, Annette ;
Heuer, Frank ;
Simon, Ulrich ;
Claes, Lutz ;
Wilke, Hans-Joachim .
SPINE, 2007, 32 (07) :748-755
[17]   Influence of a dynamic stabilisation system on load bearing of a bridged disc: an in vitro study of intradiscal pressure [J].
Schmoelz, W. ;
Huber, J. F. ;
Nydegger, T. ;
Claes, L. ;
Wilke, H. J. .
EUROPEAN SPINE JOURNAL, 2006, 15 (08) :1276-1285
[18]   Dynamic stabilization of the lumbar spine and its effects on adjacent segments - An in vitro experiment [J].
Schmoelz, W ;
Huber, JF ;
Nydegger, T ;
Claes, L ;
Wilke, HJ .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2003, 16 (04) :418-423
[19]  
Tanaka N, 2001, Spine J, V1, P47, DOI 10.1016/S1529-9430(01)00006-7
[20]  
Wilke H J, 1994, Eur Spine J, V3, P91, DOI 10.1007/BF02221446