Prospective Design Delineation and Subsequent In Vitro Evaluation of a New Posterior Dynamic Stabilization System

被引:62
作者
Wilke, Hans-Joachim [1 ]
Heuer, Frank [1 ]
Schmidt, Hendrik [1 ]
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech, D-89081 Ulm, Germany
关键词
biomechanics; finite element analysis; posterior motion preserving implants; spine arthroplasty; facet joint forces; spine mechanics; dynamic fixator; validation; FACET JOINT OSTEOARTHRITIS; FINITE-ELEMENT MODEL; LUMBAR SPINE; INTRADISCAL PRESSURE; DISC DEGENERATION; INTERVERTEBRAL DISC; STEPWISE REDUCTION; CALIBRATION METHOD; MOTION; ADJACENT;
D O I
10.1097/BRS.0b013e3181920e9c
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Finite element and in vitro study. Objective. Finite element calculations to delineate a dynamic fixator and confirmation with an in vitro experiment. Summary and Background Data. In the last few years, there was a paradigm shift from rigid to dynamic fixation of spinal segments. However, some so-called dynamic implants like the Dynesys performed still stiffer than anticipated. The aim of this study was to optimize a dynamic stabilization system. Methods. The development steps of this implant design can be summarized in a development loop. First, a finite element model of an intact human L4-L5 segment was used to delineate implant stiffness parameters for the implant, in consideration of clinical concerns and safety aspects. These data were used in a second step, leading to the final implant design. This development process was completed with an appropriate in vitro experiment. The optimal axial and bending stiffness were computed to reduce the spinal motion by 30%. For the validation process, in vitro tests were performed on 6 human lumbar spinal segments L2-L3 with a median age of 52. The model and the specimens were loaded with pure unconstrained moments of 7.5 Nm in flexion, extension, lateral bending, and axial rotation. Results. This study demonstrated the advantages of employing a finite element model for the implant parameter delineation. It was possible to prospectively outline the needed stiffness parameters for a desired spinal range of motion achievement. Conclusion. In summary, FEM may accelerate the development and the realization of a new implant design.
引用
收藏
页码:255 / 261
页数:7
相关论文
共 22 条
[1]  
Cunningham B, 2006, SAS P S HAND MONTR Q, P58
[2]   The effect of spinal destabilization and instrumentation on lumbar intradiscal pressure an in vitro biomechanical analysis [J].
Cunningham, BW ;
Kotani, Y ;
McNulty, PS ;
Cappuccino, A ;
McAfee, PC .
SPINE, 1997, 22 (22) :2655-2663
[3]   The effect of disc degeneration and facet joint osteoarthritis on the segmental flexibility of the lumbar spine [J].
Fujiwara, A ;
Lim, TH ;
An, HS ;
Tanaka, N ;
Jeon, CH ;
Andersson, GBJ ;
Haughton, VM .
SPINE, 2000, 25 (23) :3036-3044
[4]   The relationship between disc degeneration, facet joint osteoarthritis, and stability of the degenerative lumbar spine [J].
Fujiwara, A ;
Tamai, K ;
An, HS ;
Kurihashi, A ;
Lim, TH ;
Yoshida, H ;
Saotome, K .
JOURNAL OF SPINAL DISORDERS, 2000, 13 (05) :444-450
[5]   Creep associated changes in intervertebral disc bulging obtained with a laser scanning device [J].
Heuer, Frank ;
Schmitt, Herbert ;
Schmidt, Hendrik ;
Claes, Lutz ;
Wilke, Hans-Joachim .
CLINICAL BIOMECHANICS, 2007, 22 (07) :737-744
[6]   Stepwise reduction of functional spinal structures increase vertebral translation and intradiscal pressure [J].
Heuer, Frank ;
Schmidt, Hendrik ;
Claes, Lutz ;
Wilke, Hans-Joachim .
JOURNAL OF BIOMECHANICS, 2007, 40 (04) :795-803
[7]   Stepwise reduction of functional spinal structures increase range of motion and change lordosis angle [J].
Heuer, Frank ;
Schmidt, Hendrik ;
Klezl, Zdenek ;
Claes, Lutz ;
Wilke, Hans-Joachim .
JOURNAL OF BIOMECHANICS, 2007, 40 (02) :271-280
[8]   Motion in lumbar functional spine units during side bending and axial rotation moments depending on the degree of degeneration [J].
Krismer, M ;
Haid, C ;
Behensky, H ;
Kapfinger, P ;
Landauer, F ;
Rachbauer, F .
SPINE, 2000, 25 (16) :2020-2027
[9]   ACCELERATED DEGENERATION OF THE SEGMENT ADJACENT TO A LUMBAR FUSION [J].
LEE, CK .
SPINE, 1988, 13 (03) :375-377
[10]   DISC DEGENERATION AFFECTS THE MULTIDIRECTIONAL FLEXIBILITY OF THE LUMBAR SPINE [J].
MIMURA, M ;
PANJABI, MM ;
OXLAND, TR ;
CRISCO, JJ ;
YAMAMOTO, I ;
VASAVADA, A .
SPINE, 1994, 19 (12) :1371-1380