Continuous monitoring of propofol in human serum with fouling compensation by support vector classifier

被引:20
作者
Aiassa, Simone [1 ,2 ]
Hanitra, Ivan Ny [2 ]
Sandri, Gabriele [1 ,2 ]
Totu, Tiberiu [2 ]
Grassi, Francesco [1 ,2 ]
Criscuolo, Francesca [2 ]
De Micheli, Giovanni [2 ]
Carrara, Sandro [2 ]
Demarchi, Danilo [1 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, I-10129 Turin, Italy
[2] Ecole Polytech Fed Lausanne, Integrated Syst Lab, CH-1015 Lausanne, Switzerland
关键词
Anaesthesia; Continuous drug monitoring; Electrode fouling; Machine learning; Propofol; QUANTIFICATION; DEVICES;
D O I
10.1016/j.bios.2020.112666
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We present a new method for electrochemical sensing, which compensates the fouling effect of propofol through machine learning (ML) model. Direct and continuous monitoring of propofol is crucial in the development of automatic systems for control of drug infusion in anaesthesiology. The fouling effect on electrodes discourages the possibility of continuous online monitoring of propofol since polymerization of the surface produces sensor drift. Several approaches have been proposed to limit the phenomenon at the biochemical interface; instead, here, we present a novel ML-based calibration procedure. In this paper, we analyse a dataset of 600 samples acquired through staircase cyclic voltammetry (SCV), resembling the scenario of continuous monitoring of propofol, both in PBS and in undiluted human serum, to demonstrate that ML based model solves electrode fouling of anaesthetics. The proposed calibration approach is based on Gaussian radial basis function support vector classifier (RBF-SVC) that achieves classification accuracy of 98.9% in PBS, and 100% in undiluted human serum. The results prove the ability of the ML-based model to correctly classify propofol concentration in the therapeutic range between 1 mu M and 60 mu M with levels of 10 mu M, continuously up to ten minutes, with one sample every 30s.
引用
收藏
页数:7
相关论文
共 32 条
[1]   New Measurement Method in Drug Sensing by Direct Total-Charge Detection in Voltammetry [J].
Aiassa, Simone ;
Martinez, Jose David Gonzalez ;
Demarchi, Danilo ;
Carrara, Sandro .
2020 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2020,
[2]  
Aiassa S, 2019, 2019 15TH CONFERENCE ON PHD RESEARCH IN MICROELECTRONICS AND ELECTRONICS (PRIME), P265, DOI [10.1109/prime.2019.8787764, 10.1109/PRIME.2019.8787764]
[3]   Optimized Sampling Rate for Voltammetry-Based Electrochemical Sensing in Wearable and IoT Applications [J].
Aiassa, Simone ;
Carrara, Sandro ;
Demarchi, Danilo .
IEEE SENSORS LETTERS, 2019, 3 (06)
[4]   Voltammetric e-tongue for the quantification of total polyphenol content in olive oils [J].
Apetrei, Irina Mirela ;
Apetrei, Constantin .
FOOD RESEARCH INTERNATIONAL, 2013, 54 (02) :2075-2082
[5]  
Asir S, 2019, 2019 3 INT S MULTIDI, P1
[6]  
Carrara S., 2012, BIOCMOS INTERFACES C
[7]   LIBSVM: A Library for Support Vector Machines [J].
Chang, Chih-Chung ;
Lin, Chih-Jen .
ACM TRANSACTIONS ON INTELLIGENT SYSTEMS AND TECHNOLOGY, 2011, 2 (03)
[8]   SUPPORT-VECTOR NETWORKS [J].
CORTES, C ;
VAPNIK, V .
MACHINE LEARNING, 1995, 20 (03) :273-297
[9]   Calibrating chemical multisensory devices for real world applications: An in-depth comparison of quantitative machine learning approaches [J].
De Vito, S. ;
Esposito, E. ;
Salvato, M. ;
Popoola, O. ;
Formisano, F. ;
Jones, R. ;
Di Francia, G. .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 :1191-1210
[10]  
Del Valle M., 2017, Materials for Chemical Sensing, P227, DOI [10.1007/978-3-319-47835-7_9, DOI 10.1007/978-3-319-47835-7_9]