Design and Functional Evaluation of a Quasi-Passive Compliant Stance Control Knee-Ankle-Foot Orthosis

被引:49
作者
Shamaei, Kamran [1 ]
Napolitano, Paul C. [1 ]
Dollar, Aaron M. [1 ]
机构
[1] Yale Univ, Dept Mech Engn & Mat Sci, New Haven, CT 06511 USA
关键词
Compliant mechanism; knee; knee-ankle-foot orthosis (KAFO); orthotics; quasi-passive mechanism; quasi-stiffness; spinal cord injury; stance control orthosis; stroke; ENERGY; WALKING; GAIT; PROSTHESIS; ADAPTATION; SIMULATION; SPEED;
D O I
10.1109/TNSRE.2014.2305664
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we present the mechanical design, control algorithm, and functional evaluation of a quasi-passive compliant stance control knee-ankle-foot orthosis. The orthosis implements a spring in parallel with the knee joint during the stance phase of the gait and allows free rotation during the swing phase. The design is inspired by the moment-angle analysis of the knee joint revealing that the knee function approximates that of a linear torsional spring in the stance phase of the gait. Our orthosis aims to restore the natural function of a knee that is impaired by injury, stroke, post-polio, multiple sclerosis, spinal cord injury, patellofemoral pain syndrome, osteoarthritis, and others. Compared with state-of-the-art stance control orthoses, which rigidly lock the knee during the stance phase, the described orthosis intends to provide the natural shock absorption function of the knee in order to reduce compensatory movements both in the affected and unaffected limbs. Preliminary testing on three unimpaired subjects showed that compliant support of the knee provided by the orthosis explained here results in higher gait speed as well as more natural kinematic profiles for the lower extremities when compared with rigid support of the knee provided by an advanced commercial stance control orthosis.
引用
收藏
页码:258 / 268
页数:11
相关论文
共 58 条
[21]   Gait of stance control orthosis users: The Dynamic Knee Brace System [J].
Irby, SE ;
Bernhardt, KA ;
Kaufman, KR .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2005, 29 (03) :269-282
[22]   Gait changes over time in stance control orthosis users [J].
Irby, Steven E. ;
Bernhardt, Kathie A. ;
Kaufman, Kenton R. .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2007, 31 (04) :353-361
[23]   Invariant ankle moment patterns when walking with and without a robotic ankle exoskeleton [J].
Kao, Pei-Chun ;
Lewis, Cara L. ;
Ferris, Daniel P. .
JOURNAL OF BIOMECHANICS, 2010, 43 (02) :203-209
[24]  
Kaufman K., 1996, JPO: Journal of Prosthetics and Orthotics, V8, P79
[25]   Mechanical and biomechanical analysis of a linear piston design for angular-velocity-based orthotic control [J].
Lemaire, Edward D. ;
Samadi, Reza ;
Goudreau, Louis ;
Kofman, Jonathan .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2013, 50 (01) :43-52
[26]   Angular-Velocity Control Approach for Stance-Control Orthoses [J].
Lemaire, Edward D. ;
Goudreau, Louis ;
Yakimovich, Terris ;
Kofman, Jonathan .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2009, 17 (05) :497-503
[27]   Speed adaptation in a powered transtibial prosthesis controlled with a neuromuscular model [J].
Markowitz, Jared ;
Krishnaswamy, Pavitra ;
Eilenberg, Michael F. ;
Endo, Ken ;
Barnhart, Chris ;
Herr, Hugh .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2011, 366 (1570) :1621-1631
[28]   Science, medicine, and the future - Artificial limbs [J].
Marks, LJ ;
Michael, JW .
BRITISH MEDICAL JOURNAL, 2001, 323 (7315) :732-735
[29]   Agonist-antagonist active knee prosthesis: A preliminary study in level-ground walking [J].
Martinez-Vilialpando, Ernesto C. ;
Herr, Hugh .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2009, 46 (03) :361-373
[30]  
McMillan AG., 2004, JPO: Journal of Prosthetics and Orthotics, V16, P6, DOI DOI 10.1097/00008526-200401000-00004