Maximum Velocity Estimation in Coronary Arteries Using 3-D Tracking Doppler

被引:6
作者
Fiorentini, Stefano [1 ]
Saxhaug, Lars Molgaard [1 ]
Bjastad, Tore Gruner [1 ,2 ]
Holte, Espen [1 ]
Torp, Hans [1 ]
Avdal, Jorgen [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7491 Trondheim, Norway
[2] InPhase Solut AS, N-7037 Trondheim, Norway
关键词
Coronary flow imaging; Doppler effect; high frame-rate imaging; pulsed wave Doppler; sonogram; time-frequency analysis; transit-time broadening; ultrasonic imaging; TRANSTHORACIC DOPPLER; ULTRASOUND; ECHOCARDIOGRAPHY; STENOSES; FIELDS;
D O I
10.1109/TUFFC.2018.2827241
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Several challenges currently prevent the use of Doppler echocardiography to assess blood flow in the coronary arteries. Due to the anatomy of the coronary tree, out-of-plane flow and high beam-to-flow angles easily occur. Transit-time broadening in regions with high velocities leads to overestimation of the maximum velocity envelope, which is a standard clinical parameter for flow quantification. In this paper, a commercial ultrasound system was locally modified to perform trans-thoracic, 3-D high frame-rate imaging of the coronary arteries. The imaging sequence was then combined with 3-D tracking Doppler for retrospective estimation of maximum velocities. Results from simulations showed that 3-D tracking Doppler delivers sonograms with better velocity resolution and spectral SNR compared to conventional pulsed wave (PW) Doppler. Results were confirmed using in vitro recordings. Further simulations based on realistic coronary flow data showed that 3-D tracking Doppler can provide improved performance compared to PW Doppler, suggesting a potential benefit to patients. In vivo feasibility of the method was also shown in a healthy volunteer.
引用
收藏
页码:1102 / 1110
页数:9
相关论文
共 28 条
[1]  
Alnaes M, 2015, ARCHIVE NUMERICAL SO, V3, DOI DOI 10.11588/ANS.2015.100.20553
[2]   An image-based modeling framework for patient-specific computational hemodynamics [J].
Antiga, Luca ;
Piccinelli, Marina ;
Botti, Lorenzo ;
Ene-Iordache, Bogdan ;
Remuzzi, Andrea ;
Steinman, David A. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (11) :1097-1112
[3]   TIME DOMAIN FORMULATION OF PULSE-DOPPLER ULTRASOUND AND BLOOD VELOCITY ESTIMATION BY CROSS-CORRELATION [J].
BONNEFOUS, O ;
PESQUE, P .
ULTRASONIC IMAGING, 1986, 8 (02) :73-85
[4]   HIGH-RESOLUTION FREQUENCY-WAVENUMBER SPECTRUM ANALYSIS [J].
CAPON, J .
PROCEEDINGS OF THE IEEE, 1969, 57 (08) :1408-&
[5]  
Corrales M, 2017, PERSPECT LAW BUS INN, P1, DOI [10.1109/ULTSYM.2017.8092702, 10.1007/978-981-10-5038-1_1]
[6]  
Ekroll IK, 2012, IEEE T ULTRASON FERR, V59, P1182, DOI [10.1109/TUFFC.2012.2308, http://dx.doi.org/10.1109/TUFFC.2012.2308]
[7]  
Fiorentini S., 2017, P IEEE INT ULTR S IU, P1
[8]   2-D Tracking Doppler: A New Method to Limit Spectral Broadening in Pulsed Wave Doppler [J].
Fredriksen, Tonje D. ;
Ekroll, Ingvild K. ;
Lovstakken, Lasse ;
Torp, Hans .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (09) :1896-1905
[9]   Adaptive Spectral Doppler Estimation [J].
Gran, Fredrik ;
Jakobsson, Andreas ;
Jensen, Jorgen Arendt .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (04) :700-714
[10]   Transthoracic Doppler for detection of stenoses in the three main coronary arteries by use of stenotic to prestenotic velocity ratio and aliased coronary flow [J].
Holte, Espen ;
Vegsundvag, Johnny ;
Hegbom, Knut ;
Hole, Torstein ;
Wiseth, Rune .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (12) :1323-1330