Wear Debris Characterization and Corresponding Biological Response: Artificial Hip and Knee Joints

被引:117
作者
Nine, Md J. [1 ]
Choudhury, Dipankar [1 ,2 ]
Hee, Ay Ching [1 ]
Mootanah, Rajshree [3 ]
Abu Osman, Noor Azuan [1 ]
机构
[1] Univ Malaya, Dept Biomed Engn, Fac Engn, Kuala Lumpur 50603, Malaysia
[2] Brno Univ Technol, Fac Mech Engn, Brno 61669, Czech Republic
[3] Anglia Ruskin Univ, Fac Sci & Technol, Dept Engn & Built Environm, Med Engn Res Grp, Chelmsford CM1 1SQ, Essex, England
关键词
wear debris; isolation; morphology; biological response; nano-toxicity; METAL-ON-METAL; MOLECULAR-WEIGHT POLYETHYLENE; TRANSMISSION ELECTRON-MICROSCOPY; BLOOD MONONUCLEAR PHAGOCYTES; CROSS-LINKED POLYETHYLENE; REVISION TOTAL HIP; IN-VITRO; UHMWPE WEAR; PERIPROSTHETIC TISSUE; PARTICLE-SIZE;
D O I
10.3390/ma7020980
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Wear debris, of deferent sizes, shapes and quantities, generated in artificial hip and knees is largely confined to the bone and joint interface. This debris interacts with periprosthetic tissue and may cause aseptic loosening. The purpose of this review is to summarize and collate findings of the recent demonstrations on debris characterization and their biological response that influences the occurrence in implant migration. A systematic review of peer-reviewed literature is performed, based on inclusion and exclusion criteria addressing mainly debris isolation, characterization, and biologic responses. Results show that debris characterization largely depends on their appropriate and accurate isolation protocol. The particles are found to be non-uniform in size and non-homogeneously distributed into the periprosthetic tissues. In addition, the sizes, shapes, and volumes of the particles are influenced by the types of joints, bearing geometry, material combination, and lubricant. Phagocytosis of wear debris is size dependent; high doses of submicron-sized particles induce significant level of secretion of bone resorbing factors. However, articles on wear debris from engineered surfaces (patterned and coated) are lacking. The findings suggest considering debris morphology as an important parameter to evaluate joint simulator and newly developed implant materials.
引用
收藏
页码:980 / 1016
页数:37
相关论文
共 170 条
[71]   Production of TNF-α and bone resorbing activity by macrophages in response to different types of bone cement particles [J].
Ingham, E ;
Green, TR ;
Stone, MH ;
Kowalski, R ;
Watkins, N ;
Fisher, J .
BIOMATERIALS, 2000, 21 (10) :1005-1013
[72]   Reduction of polyethylene wear by concave dimples on the frictional surface in artificial hip joints [J].
Ito, H ;
Kaneda, K ;
Yuhta, T ;
Nishimura, I ;
Yasuda, K ;
Matsuno, T .
JOURNAL OF ARTHROPLASTY, 2000, 15 (03) :332-338
[73]   Wear particles [J].
Jacobs, JJ ;
Hallab, NJ ;
Urban, RM ;
Wimmer, MA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A :99-102
[74]   Analysis of polyethylene particles isolated from periprosthetic tissue of loosened hip arthroplasty and comparison with radiographic appearance [J].
Koseki, H ;
Matsumoto, T ;
Ito, S ;
Doukawa, H ;
Enomoto, H ;
Shindo, H .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2005, 10 (03) :284-290
[75]   Surface-engineered metal-on-metal bearings improve the friction and wear properties of local area contact in total joint arthroplasty [J].
Koseki, Hironobu ;
Shindo, Hiroyuki ;
Baba, Koumei ;
Fujikawa, Takamasa ;
Sakai, Nobuo ;
Sawae, Yoshinori ;
Murakami, Teruo .
SURFACE & COATINGS TECHNOLOGY, 2008, 202 (19) :4775-4779
[76]   Isolation and analysis of articular joints wear debris generated in vitro [J].
Kowandy, C. ;
Mazouz, H. ;
Richard, C. .
WEAR, 2006, 261 (09) :966-970
[77]   Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: A knee simulator study [J].
Kretzer, J. Philippe ;
Jakubowitz, Eike ;
Reinders, Joern ;
Lietz, Eva ;
Moradi, Babak ;
Hofmann, Kerstin ;
Sonntag, Robert .
ACTA BIOMATERIALIA, 2011, 7 (02) :710-715
[78]  
Kurtz S.M., 2004, UHMWPE Biomaterials Handbook TJltra-High Molecular Weight Polyethylene in Total Joint Replacement and Medical Device
[79]   Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty [J].
Kurtz, SM ;
Muratoglu, OK ;
Evans, M ;
Edidin, AA .
BIOMATERIALS, 1999, 20 (18) :1659-1688
[80]   Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030 [J].
Kurtz, Steven ;
Ong, Kevin ;
Lau, Edmund ;
Mowat, Fionna ;
Halpern, Michael .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (04) :780-785